TPL VISION LITE LBAR+ Series Скачать руководство пользователя страница 6

eqUIPment maIntenance

Cleaning (when the product is switched off)
Please use a soft and dry cloth. Do not use any abrasive material.
Do not use any cleaning solvent or aggressive chemical product.
TPL Vision recommends to use isopropyl alcohol.

USer SecUrIty

do respect the power supply voltages and the connection terminals.

do not modify or dismantle all or part of the product.

do not connect or clean when power is on.

do not watch the lighting source directly, and follow the advice below :

•  If the workstation enables it, interpose a filter that will stop the lighting radiation under fixed or adjustable 

frame between the source and the operator.

•  When these measures cannot be implemented, supply the operators with glasses (class 4) available for sale 

at TPL Vision, or with a dedicated protective mask, that will stop the lighting radiation.

•  Forbid or limit the direct access to the lighting source (exposure into the radiation axis).

•  Establish a security perimeter so as to prevent the operators from approaching the lighting source beyond 

the recommendations of the manufacturer, as for eye irritation is concerned.

•  In any case, ensure that the chosen means properly reduce the exposition quantities (features of screens or 

glasses to be chosen, according to the wavelengths that the operators are exposed to).

USer gUIde

P6/8

Содержание LITE LBAR+ Series

Страница 1: ...ut lighting fluxes enables the classification of led lightings in 4 distinct groups according to their hazardousness degree Please find below an indicative table recapitulating the classes of risk for our standard products unpacking Products are packed in our factory using suitable materials for a safe transport through the usual means of trans portation in France and internationally However a dam...

Страница 2: ...600 mm 2 M4 nuts n 600 mm Lg 1250 mm 3 M4 nuts n 1250 mm Lg 1750 mm 4 M4 nuts During the set up the light has to be switched off and unplugged Please use the delivered nuts and insert them in the groove located in the back of the light The light will be better fixed if you spread the attachment points as indicated on the scheme above You can also use M4 screws not supplied with a tightening torque...

Страница 3: ...d PNP 24V NPN 1 2 3 4 Ground CONTINUOUSMODE or 2 4 1 24V 3 GND 5 DIM0 10V STROBE NPN STROBE PNP 5 Dim0 10V 5 Dim0 10V 5 Dim0 10V black brown blue grey white Dimensions 250 500 750 1000 1250 1500 1750 Max voltage drop in the bar V 0 02 0 08 0 18 0 31 0 49 0 70 0 96 Power supply cable max length 5x0 34 for acceptable voltage drop m 150 150 150 116 89 69 55 Voltage drop If you use an angled connector...

Страница 4: ...to the time during which the strobe entry is activated Strobe PNP NPN Dimming 0 10V 20 40 60 80 100 0 2 4 6 8 10 VOLTS Potential dimming between 0 10 V At 0 Volts the product reaches 100 of its lighting power PNP from 5 to 24V for 100 ON From 0 to 1V for 100 OFF NPN less than 1V for 100 ON Above 2V for 100 OFF Max 20V Strobe Mode Entrée Déclenchement Sortie Éclairage Triggering input Light 15 µs 1...

Страница 5: ...ower Lite LBAR 250 LBAR 4 30 mm Power LBAR4 20 Lite LBAR 500 LBAR 8 60 mm Power LBAR8 20 Lite LBAR 750 LBAR 12 90 mm Power LBAR12 20 Lite LBAR 1000 LBAR 16 120 mm Power LBAR16 20 Lite LBAR 1250 LBAR 20 150 mm Power LBAR20 20 Lite LBAR 1500 LBAR 24 180 mm Power LBAR24 20 Lite LBAR 1750 LBAR 28 210 mm Power LBAR28 20 Equivalence Lite LBAR 250 Essential EBAR 250 x 0 75 Lite LBAR 500 Essential EBAR 50...

Страница 6: ...lighting radiation under fixed or adjustable frame between the source and the operator When these measures cannot be implemented supply the operators with glasses class 4 available for sale at TPL Vision or with a dedicated protective mask that will stop the lighting radiation Forbid or limit the direct access to the lighting source exposure into the radiation axis Establish a security perimeter s...

Страница 7: ......

Страница 8: ...TPL VISION UK Brenchley House School Road Charing Kent TN27 0JW UK Tel 44 0 1738 310 392 www tpl vision com Features and presentations liable to changes without notice Ref UG 010601 D2 2020 01 edition ...

Отзывы: