background image

Preamble

This notice includes all the advice and warnings that enables a correct set up and a safe use of the product. 
TPL Vision can not be responsible for the bad use of the notice. If so, TPL Vision cancels the guarantee’s effects.

rISk claSS

Colour

Class

Risk

White WHI, Green 525 nm, Red 630 nm

0

none

UV 405 nm, Blue 470 nm, IR 850 nm

1

low

UV 365 nm

2

moderate

UV 385 nm

3

high

In all cases, TPL Vision recommends 
the use of the protection glasses 
that are listed in its catalog.

For more information about photo-
biological risks, do not hesitate to 
contact us.

USer gUIde

TPL Vision can provide calculation notes about the nominal distance of eye risks (security distance).

BewaRe to the infrared light, invisible to the eyes.
To know if the light is on, please refer to the LED indicators.

The EN-62471 norm about lighting fluxes enables the classification of led lightings in 4 distinct groups, according 
to their hazardousness degree. Please find below an indicative table, recapitulating the classes of risk for our 
standard products.

UnPackIng

Products are packed in our factory, using suitable materials for a safe transport through the usual means of trans-
portation, in France and internationally. However, a damaged package must be reported to the carrier on delivery. 
Hand-written reservations must be indicated on the delivery order. Moreover, please send a letter or an email to 
TPL Vision as soon as possible (up to 24 hours after the delivery). If the transportation damage has not been stipu-
lated on the delivery order and reported to TPL Vision in time, the package will not be taken back nor exchanged. 
To open the package, do not use any cutting blade to avoid damaging the product(s). Please use the delivered 
accessories, if needed (do not use any other products or equivalents to replace the delivered accessories).

Содержание LITE LBAR+ Series

Страница 1: ...ut lighting fluxes enables the classification of led lightings in 4 distinct groups according to their hazardousness degree Please find below an indicative table recapitulating the classes of risk for our standard products unpacking Products are packed in our factory using suitable materials for a safe transport through the usual means of trans portation in France and internationally However a dam...

Страница 2: ...600 mm 2 M4 nuts n 600 mm Lg 1250 mm 3 M4 nuts n 1250 mm Lg 1750 mm 4 M4 nuts During the set up the light has to be switched off and unplugged Please use the delivered nuts and insert them in the groove located in the back of the light The light will be better fixed if you spread the attachment points as indicated on the scheme above You can also use M4 screws not supplied with a tightening torque...

Страница 3: ...d PNP 24V NPN 1 2 3 4 Ground CONTINUOUSMODE or 2 4 1 24V 3 GND 5 DIM0 10V STROBE NPN STROBE PNP 5 Dim0 10V 5 Dim0 10V 5 Dim0 10V black brown blue grey white Dimensions 250 500 750 1000 1250 1500 1750 Max voltage drop in the bar V 0 02 0 08 0 18 0 31 0 49 0 70 0 96 Power supply cable max length 5x0 34 for acceptable voltage drop m 150 150 150 116 89 69 55 Voltage drop If you use an angled connector...

Страница 4: ...to the time during which the strobe entry is activated Strobe PNP NPN Dimming 0 10V 20 40 60 80 100 0 2 4 6 8 10 VOLTS Potential dimming between 0 10 V At 0 Volts the product reaches 100 of its lighting power PNP from 5 to 24V for 100 ON From 0 to 1V for 100 OFF NPN less than 1V for 100 ON Above 2V for 100 OFF Max 20V Strobe Mode Entrée Déclenchement Sortie Éclairage Triggering input Light 15 µs 1...

Страница 5: ...ower Lite LBAR 250 LBAR 4 30 mm Power LBAR4 20 Lite LBAR 500 LBAR 8 60 mm Power LBAR8 20 Lite LBAR 750 LBAR 12 90 mm Power LBAR12 20 Lite LBAR 1000 LBAR 16 120 mm Power LBAR16 20 Lite LBAR 1250 LBAR 20 150 mm Power LBAR20 20 Lite LBAR 1500 LBAR 24 180 mm Power LBAR24 20 Lite LBAR 1750 LBAR 28 210 mm Power LBAR28 20 Equivalence Lite LBAR 250 Essential EBAR 250 x 0 75 Lite LBAR 500 Essential EBAR 50...

Страница 6: ...lighting radiation under fixed or adjustable frame between the source and the operator When these measures cannot be implemented supply the operators with glasses class 4 available for sale at TPL Vision or with a dedicated protective mask that will stop the lighting radiation Forbid or limit the direct access to the lighting source exposure into the radiation axis Establish a security perimeter s...

Страница 7: ......

Страница 8: ...TPL VISION UK Brenchley House School Road Charing Kent TN27 0JW UK Tel 44 0 1738 310 392 www tpl vision com Features and presentations liable to changes without notice Ref UG 010601 D2 2020 01 edition ...

Отзывы: