background image

LED INDICATOR 

The SP597 uses a multi-colored LED to indicate operational status. 

 

Orange

 blinking LED 

 SP597 is on and ready to connect to the smart device 

 

Green

 blinking LED 

 SP597 is connected to a smart device 

 

Red 

blinking LED 

 Batteries need to be replaced 

 

Orange

 and 

Green

 blinking LED 

 Data logging active and SP597 is not connected to the app. 

 

AUTO POWER OFF 

If the SP597 is not connected to a smart device for more than 8 minutes it will auto power off. When 
connected to a smart device the auto power off is disabled. Auto power off is also disabled during data 
logging. 

 

DATA LOGGING

 

The SP597 has the ability to log readings with a time and date stamp. The maximum number of 
readings that can be logged is 5,000. 

1.

 

Connect to the SP597 as outlined earlier. 
 

2.

 

Select 

‘Logger’ in the View App.

 

 
3.

 

Set the logging interval in minutes/second and the end time and date. 
 

4.

 

Tap on ‘Start Logging’ and the 

SP597 will begin logging data. 

 
5.

 

The View app can be disconnected from the SP597 and logging will continue until the end 
time is reached or the View app is reconnected and logging is stopped. When the SP597 is 
in logging mode and disconnected from the View app, the SP597 LED will blink green and 
orange. 

 
6.

 

Once logging has been stopped or ended, logged data can be retrieved using the View app.  

 

 

 

 

Содержание SP597

Страница 1: ...SP597 Smart Humidity Temperature Probe Instruction Manual Scan to download the TPI View app ...

Страница 2: ...e live readings will be displayed on the app Units are selectable by tapping on the temperature box Dry Bulb Wet Bulb Dew Point and Enthalpy Connecting two SP597 smart probes allows for the following calculations to be made for Return and Supply air Dry Bulb Wet Bulb Dew Point and Enthalpy 1 Turn one or both SP597 and open the app Tap on Enthalpy and then tap on Select to assign a SP597 to the Ret...

Страница 3: ...so disabled during data logging DATA LOGGING The SP597 has the ability to log readings with a time and date stamp The maximum number of readings that can be logged is 5 000 1 Connect to the SP597 as outlined earlier 2 Select Logger in the View App 3 Set the logging interval in minutes second and the end time and date 4 Tap on Start Logging and the SP597 will begin logging data 5 The View app can b...

Страница 4: ...n the Smart Probe app SPECIFICATIONS Humidity Range 0 RH to 100 RH Resolution 0 1 RH Accuracy 3 RH 20 RH to 80 RH at 25 C 5 RH 20 RH and 80 RH at 25 C Temperature Range 4 F to 140 F 20 C to 60 C Resolution 0 1 F 0 1 C Accuracy 32 F to 140 F 0 C to 60 C 0 1 F 0 5 C 32 F 0 C 2 F 1 0 C General Data Logging 5 000 readings in 1 sec to 59 min 59 sec intervals Battery Life Approximately 200 hours Battery...

Страница 5: ...tion of incidental or consequential damages so the above limitations or exclusions may not apply to you To Obtain Warranty Performance Include with the product your name address phone number written description of the problem and proof of purchase date Carefully package and return to TPI Inc TPI Canada TPI Europe Ltd 9615 SW Allen Blvd 342 Bronte Rd S Unit 6 Unit 6 Beaverton OR 97005 Milton Ontari...

Страница 6: ...NOTES ...

Страница 7: ...NOTES ...

Страница 8: ...www testproductsintl com Test Products International Ltd 342 Bronte Road South Unit 6 Milton Ontario Canada L9T 5B7 Tel 905 693 8558 www tpicanada com Test Products International Europe Ltd Rutherford Way Industrial Estate Rutherford Way Manor Royal Crawley West Sussex RH10 9LN www tpieurope com ...