background image

Tuffman Pressure Meter

TPI 635 / 645 / 655

www.

.com

[email protected]

1.800.561.8187

Содержание 635

Страница 1: ...Tuffman Pressure Meter TPI 635 645 655 www com information itm com 1 800 561 8187 ...

Страница 2: ...Data International Symbols Page 6 Features Benefits Page 7 Pressure Conversion Table Page 8 Step by Step Procedures Page 9 Accessories Specifications Page 10 Maintenance Page 11 Trouble Shooting Guide EC declaration of conformity Page 12 Warranty Statement page 1 www com information itm com 1 800 561 8187 ...

Страница 3: ...istration card Product Description The TPI 600 Tuffman series is a hand held range Of pressure meters and can be summarized as follows TPI 635 5 PSI pressure range TPI 645 30 PSI pressure range TPI655 100 PSI pressure range All of these models are dual input differential pressure meters with 7 selectable scales to choose from mbar kPa PSI inHg mmHg inH20 and mH20 page 2 www com information itm com...

Страница 4: ... Ensure that the connecting hose you are using is free from kinks or splits Double check all connections before testing NEVER Connect the instrument to an unknown pressure source if the source is twice the working pressure of the instrument the sensor will be damaged and may cause injury to the user Tamper with the instrument or attempt to modify it in any way Otherwise accident and injury may occ...

Страница 5: ...nables user to recall display both the maximum and minimum pressure recorded since the function was selected Press button once to activate twice to read minimum and three times to read the maximum To cancel the function press and the hold the MAXIMIN button HOLD Maintains the reading on the LCD display UNITS Selects 7 units of measure kPa PSI inHg mmHg inH20 mH 20 mbar page 4 www com information i...

Страница 6: ...values previously measured Zero function Provides immediate push button zeroing for Speed and accuracy Record Max Min Enables long term testing of pressure systems for leaks Hold Enables the user to freeze the display reading when working in cramped working conditions when the display is not visible Units Change the display value in anyone of the following engineering units kPa PSI inHg mmHg inH20...

Страница 7: ...301 x 10 2 1 7 35561 X 10 2 2 036 3 937 X 10 2 2 89591 0 295301 in H20 406 8 0 401463 13 5951 1 27 68 0 534 39 3701 4 01463 PSI 14 6959 1 45038 x 10 2 0 491153 3 61273 X 10 2 1 1 934 X 10 2 1 42233 0 145038 mmHg 760 0 750064 25 4 1 86833 51 715 1 73 5561 7 50064 mH20 10 3323 1 01972 x 10 2 0 345315 2 54 X 10 2 0 70307 1 35951 X10 2 1 0 101972 kPa 101 325 0 1 3 38638 0 249089 6 89476 0 133322 9 806...

Страница 8: ...he display To activate the backlight in poor light conditions press the ON key at any time If the reading is erratic or changing activate the smoothing unction by pressing the key To freeze a reading in awkward or cramped working spaces press the Hold key To record maximum minimum pressures when establishing pressure decay or carrying out gas line soundness testing press the MAXIMIN key To convert...

Страница 9: ...9VL Features Model 635 645 655 Range 5 PSI 30 PSI 100 PSI Accuracy O 2 of full scale 3 digits Over Pressure 14 5 psi 1000 mbar 58 0 psi 4000 mbar 145 psi 10 bar Power Supply 9V Relative Humidity 0 to 80 a to 40 C Operating Temp 32 to 104 F D to 40 C Storage Temp 14 to 122 F 10 10 50 C Auto Power Off After 30 minutes Trim Mode Yes Zero Adjust Yes Push Button Data Hold Yes Record Yes Max Min page 8 ...

Страница 10: ... screw on the battery compartment cover 3 Remove battery compartment cover 4 Remove old battery 5 Replace with new battery 9V NEDA 1604 or equivalent 6 Reassemble the instrument in reverse order from above 7 RE fit the cross head screw being sure not to over tighten Cleaning Use a mild detergent and a slightly damp cloth to clean the surfaces of the instrument page 9 www com information itm com 1 ...

Страница 11: ...ity This is to certify that model 634 645 655 conform to the protection requirements of the council directive 89 336 EEC in the approximation of laws of the member states relating to Electromagnetic compatibility by application of the following standards EN50081 1 1992 Emissions Standard EN50082 1 1992 Immunity Standard To ensure conformity with these standards this instrument must be operated in ...

Страница 12: ...purchaser are also covered Not covered by TPI Damage to the product which are the result of abuse improper use or maintenance are not covered Any other expense conse quential damages incidental expenses including damages to property is not covered Transportation expense to the company are not covered To obtain warranty performance include with the product your name address phone number written des...

Отзывы: