background image

PARTS VIEW AND PARTS LIST ..Directional Air Heater Final Assembly 

Unit 

Length 

Item 

Part No. 

Description 

Qty 

33” 





** 
** 

52293001 
62273001 
58337001 

Heat deck assbly-SNG 

Blower deck assembly-SNG 

Disposable filter-SNG 

Intake/discharge grille* 

Front Panel 





46” 





** 
** 

52293002 
62273002 
58337002 

Heat deck assbly-DBL 

Blower deck assembly-DBL 

Disposable filter-DBL 

Intake/discharge grille* 

Front Panel 





66” 

 

 

 


** 
** 
** 
** 

52293001 
52293002 
62273003 
58337003 

Heat deck assbly-SNG  

Heat deck assbly-DBL 

Blower deck assembly-SNG 

Blower deck assembly-DBL 

Disposable filter-SNG 

Disposable filter-DBL 

Intake/discharge grille* 

Front Panel 








79” 





** 
** 

52293002 
62273004 
58337004 

Heat deck assbly-DBL 

Blower deck assembly-DBL 

Disposable filter-DBL 

Intake/discharge grille* 

Front Panel 





 

 

Voltage 

Item 

Control Options 

B1/B8 

B2/B7 

B3/B5 

B4/B6 

208-3/1 


2

 

51135006 
58027006 

N/R 

51135001 
58027001 

N/R 

51135001 
58027001 
60719037 

51135006 
58027002 
41043001 

240-3/1 

&415-3 

2

Π

 

51135006 
58027002 

N/R 

51135001 
58027001 

N/R 

51135001 
58027001 
60719037 

51135006 
58027002 
41017001 

277-1& 

480-3 

4-wire 



51135006 
58027002 

N/R 

51135001 
58027001 

N/R 

51135001 
58027001 
60719011 

51135006 
58027002 
41017009 

480-1& 

480-3 

3-wire 



51135006 
58027002 

N/R 

51135001 
58027001 

N/R 

51135001 
58027001 
60719012 

51135006 
58027002 
41017001 

600-3/1 



51135006 
58027002 

N/R 

51135001 
58027001 

N/R 

51135001 
58027001 
60719040 

51135006 
58027002 
58342002 

All 



 
 

 

42438001 

Optional 
Optional 

42438001 

Optional 
Optional 

42438001 

Optional 
Optional 

42438001 
44066001 
40062001 

B1 thru B4 – 93854088 
B5 thru B8 – 93854112 

 

 

Π

 Excludes 208/240V 3-phase 66” and 79” units, 18 and 24 KW. 

    Consult factory.  See page 7 for description of control options

 

High/Low 

Thermostat 

ISSUE DATE 06/15/01      REV. DATE  

REV. NO. 00         ECO NO. 1-4635         P/N 00009979       

             SHT.  05 OF 09 

4” 

Π

 

Summer Fan 

(optional) 

5 & 6 

Fuse/Holder

 

Transformer 

Contractor 

ΠΠΠ

Contactor 

Fan Relay 

1



 

Summer Fan 

(optional) 

*Field adjustable for various configurations 
**See page 6 for individual parts 

Switch available on all units except 480V, 3-phase, 

3-wire and 600V, 3-phase and single phase units. 

 



Required for optional summer fan in 480V, 3-

phase, 3-wire, and 600V, 3-phase and single units. 

 



For 415/240 and 480/277 ST Option Contact 

Factory for part number. 

Содержание 6300/T Series

Страница 1: ...bs 4 thru 12KW Heater W66 H25 D9 1 2 215lbs 6 thru 18KW Heater W79 H25 D9 1 2 248lbs 8 thru 24KW Heater SPECIFICATIONS Read all instructions before using this heater 1 Follow all local and electrical codes the National Electric code NEC and the Occupational Safety and Health Act OSHA 2 Before attempting any electrical connections or inspections for any reason to service the heater make sure that t...

Страница 2: ... and 600 volt 3 phase units are all single speed only If external load management control of the unit is desired replace factory installed jumper wire on the control terminal block with leads from the external management control Refer to page 7 for description of control options OPERATING INSTRUCTIONS SYMPTOM POSSIBLE CAUSE S CORRECTIVE ACTION Heater does not energize 1 Defective thermostat 2 Defe...

Страница 3: ...es are indicated for each mounting configuration In all positions clearance from end of heater to a side wall is zero inches Mounting holes are provided in the back of the cabinet accessible through the blower compartment If necessary remove blower deck if additional mounting screws or bolts are desired Blower deck may be slipped forward by loosening four screws at the front to provide access to m...

Страница 4: ...s are provided in the back of the wiring compartment Make sure all field wiring connections are properly made and are tight Electrical Ground This heater must be grounded before operating as required by the National Electric Code and by applicable local codes Use a conductor of the appropriate size secured to the ground lug in the heater and to a grounded connection in the service panel Typical Wi...

Страница 5: ...1 58027001 60719037 51135006 58027002 41017001 277 1 480 3 4 wire 1 2 3 51135006 58027002 N R 51135001 58027001 N R 51135001 58027001 60719011 51135006 58027002 41017009 480 1 480 3 3 wire 1 2 3 51135006 58027002 N R 51135001 58027001 N R 51135001 58027001 60719012 51135006 58027002 41017001 600 3 1 1 2 3 51135006 58027002 N R 51135001 58027001 N R 51135001 58027001 60719040 51135006 58027002 5834...

Страница 6: ...001 Blower wheel 1 46 208 240 3 1 1 52290001 208 240V Motor Double shaft 1 415 3 4wire 52290001 208 240V Motor Double shaft 277 1 52290003 277V Motor Double shaft 480 3 3wire 1 52290004 480V Motor Double shaft 480 3 4wire 52290003 277V Motor Double shaft 600 3 1 52290005 575V Motor Double shaft All 3 1 2 62441001 Blower wheel 2 66 208 240 3 1 1 52289001 208 240V Motor single shaft 1 415 3 4wire 52...

Страница 7: ...re operated by and internal 24 volt source B4 Built in single stage thermostat and relays which are operated by an internal 120 volt source also includes fusing in the fan circuit and the transformer primary B5 Built in two stage thermostat and relays which are operated by and internal 24 volt source B6 Built in two stage thermostat and relays which are operated by an internal 120 volt source also...

Страница 8: ...NS ISSUE DATE 06 15 01 REV DATE REV NO 00 ECO NO 1 4635 P N 00009979 SHT 08 OF 09 ΠComes factory wired as a 3 phase unit can be field converted to single phase ΠΠcomes factory wired as 480V 3 phase 4 wire unit can be field converted to 277V single phase T 46 D 08 24 1 2 B3 S C M F D P A B C D E F G H I J K L M N A Series designation T B Cabinet size 33 33 in 46 46 in 66 66 in or 79 79 in C Inlet o...

Страница 9: ...1 73 14 12 25 12 9 39 14 10 5 10 6 49 98 6 43 57 6 37 70 6 21 79 10 17 45 10 35 06 8 30 68 8 16 66 10 15 35 12 15 87 12 12 28 12 12 6 12 6 59 59 4 51 90 6 44 92 6 25 95 8 20 78 10 35 06 8 30 68 8 18 56 10 15 35 12 15 87 12 12 28 12 66 6 2 2 6 3 1550 1400 31 75 8 27 90 8 24 12 8 13 95 12 11 29 14 27 58 8 24 29 8 12 25 12 14 32 12 9 82 14 9 Π3 3 9 6 46 17 6 40 40 8 34 99 8 20 20 10 16 29 12 27 58 8 ...

Страница 10: ...ion trim fr trim fr trim fr trim fr trim frames are for decor ames are for decor ames are for decor ames are for decor ames are for decora a a a a tive use onl tive use onl tive use onl tive use onl tive use only they are y they are y they are y they are y they are not not not not not made for supporting the cabinet unit hea made for supporting the cabinet unit hea made for supporting the cabinet ...

Страница 11: ...ns or limitations may not apply to you During the warranty period TPI Corporation will at its sole option repair or replace any defective parts or products returned freight prepaid to the TPI Corporation factory or such other locations as TPI Corporation may designate Returned products must be packaged carefully and TPI Corporation shall not be responsible for damage in transit When returning part...

Отзывы: