Title : Tpi580
2/5
1. Features
Hot wire / Vane Combo unit.
Smart probe : Interchangeable probe.
Probe hot wire/vane auto recognition.
CFM / CMM Measurement ( V
olume
calculate )
Backlight
Bluetooth LE / Apps for Android / iOS ( Model : Tpi580BT Only )
Auto power off ( 15 min )
2. Function and Accuracy
Function
Description
Hotwire Air
Range
0.2 m/s ~ 20 m/s
Resolution
0.01 m/s
Accuracy
±( 5% + 1digit ) or
±( 1% + 1digit ) F.S
Unit
m/s, km/h, mph, fpm
Vane Air
Range
1 m/s ~ 25 m/s
Resolution
0.1 m/s
Accuracy
±( 2% + 3digit )
Unit
m/s, km/h, mph, fpm
Temperature
Range
-20 °C ~ 60 °C ( -4 °F ~ 140 °F )
Resolution
0.1 °C ( 0.1 °F)
Accuracy
± 0.5 °C ( 0 °C ~ 45 °C )
± 1 °C ( -20 °C ~ 0°C, 45°C ~ 60°C )
± 1 °F ( 32 °F ~ 113 °F )
± 2 °F ( -4 °F ~ 32°F, 113°F ~ 140°F )
Others
Airflow(volume)
calculate
CFM, CMM.
REC, HOLD
MIN, MAX, AVG, Data HOLD
Operation
environment
-20 °C ~ 60 °C ( -4 °F ~ 140 °F ) at <75%RH
Communication
Bluetooth LE ( Tpi580BT only )
Battery
4.5V ( AA size x 3)
Battery life time
Hot air probe : about. 30h Vane air probe : about. 68h
Auto power off
15 min ( if APO is active )