26
25
g. Continuity Buzzer
WARNING!
Do not attempt to make continuity measurements with
circuit energize
d.
I
Instrument set-up:
FUNCTION
BLACK TEST LEAD
RED TEST LEAD
COM
Measurement Procedure:
1. Disconnect power to circuit to be measured.
2. Plug black test lead into the
COM
input jack.
3. Plug red test lead into the
input jack.
4. Set the rotary switch to the
function.
5. Press the yellow push button to activate the continuity
buzzer.
6. Connect test leads to circuit to be measured.
7. Listen for the buzzer to confirm continuity.
h. Measuring Capacitance
WARNING!
All capacitance measurements are to be made on de-
energized circuit with all capacitors
Discharged only. Failure to de-energize and discharge
capacitors before attempting to measure them could result
in instrument damage and/or personal injury.
FUNCTION BLACK
RED
MINIMUM
MAXIMUM
TEST LEAD
TEST LEAD
READING
READING
COM
0.001uF
20.00mF
0.1nF
120.0uF(Only 192)
Measurement Procedure:
1. Disconnect power to circuit to be measured.
2. Remove capacitor from the circuit and discharge it.
3. Plug black test lead into the
COM
input jack.
4. Plug the red test lead into the
input jack.
5. Set the rotary switch to the
function.
6. Connect test leads to capacitor to be measured.
7. Read the capacitor value on the LCD.