background image

6. Retrieving Logged Data

Logged data can be displayed on the 1008a display or sent to a PC by using the
USB cable and software included. The PC software also provides the capability of
real time monitoring from a PC.

Recalling and Displaying Logged Data

Retrieving Logged Data via PC

To retrieve logged data the USB cable and PC software (both supplied) must be
used.

Install the PC software on your PC and open it.

Connect the 1008a to the PC using the USB cable.

Run the software and select 1008a when prompted. Click on the connect to PC
button in the software window.

The software can be used to retrieve logged data and for real time monitoring.

COM port setting is:

Baud rate: 19200
Parity: None
Data Bits: 8
Stop Bit: 1

1) Press the

key, “LOG 01” and the logged CO2 and temperature reading

will alternately flash. Press the 

to cycle through all of the logged 

data. 

2) To deactivate recall mode and return to normal operation, press the

key.

www.

.com

[email protected]

1.800.561.8187

Содержание 1008a

Страница 1: ...1008a Rev 3x Meters Indoor Air Quality Meter The Value LeaderTM www com information itm com 1 800 561 8187 ...

Страница 2: ...2 Selecting Temperature Units 4 3 Min Max Mode 4 4 Activating the Backlight 4 5 Printing Test Results 4 6 Setting CO2 Alarm Level 4 7 Ambient Air CO2 Reset 5 Data Logging 6 Retrieving Logged Data 7 Technical Specifications 8 Maintenance 8 1 Battery Replacement 8 2 Service 9 Technical Information 10 Error Codes Troubleshooting www com information itm com 1 800 561 8187 ...

Страница 3: ...sure carbon dioxide CO2 and temperature The CO2 sensor in your meter will need to be replaced periodically and calibration is recommended once every year You should keep battery power applied to your sensors at all times The following guidelines will help prevent damage to your sensors Always store your unit in a place where the temperature does not get down to or below freezing Always maintain ba...

Страница 4: ...A803 Instruction Manual Your TPI 1008a Indoor Air Quality meter has the following optional accessories available Power adapter Battery eliminator A804 Infrared Printer A740 Magnetic strap kit to hang meter A127 Boot hook to hang meter A103 Replacement Software only A802 Replacement USB cable only A801 Denotes part number A804 Battery Eliminator Specifications Input 100 240VAC 47 63Hz Output 5VDC 2...

Страница 5: ...n to meter housing and sen sors Keypad Selects all available functions USB Port Location for connection of USB cable for PC communication Power Adapter Socket Location to connect power adapter Display Keypad CO2 Temperature Sensor Location USB Port Power Adapter Socket Protective Rubber Boot Infrared Window for Printing Test Results Requires optional A740 printer www com information itm com 1 800 ...

Страница 6: ...ress to switch between Celsius and Fahrenheit units Press and hold to enter and exit CO2 alarm level mode Backlight key Used to turn the display backlight on and off Min Max key Used to activate and cycle through minimum maximum and average display modes Press to activate Min Max mode press repeatedly to cycle through min max and avg dis plays Press and hold to deactivate Min Max mode Log key Used...

Страница 7: ...ole Use to hang instrument for hands free operation Can be used with A127 magnetic strap kit or A103 hook Tilt Stand Use to stand instrument on a table Batter Cover Loosen this screw and open cover to access batteries Screw www com information itm com 1 800 561 8187 ...

Страница 8: ...operation The 1008a has a CO2 alarm If the CO2 level measured is at or above the set alarm level the 1008a will beep and the display will flash red as a warning This alarm point is adjustable Additional functions can be acti vated during testing Please see next sections Carbon dioxide CO2 Temperature Battery indicator Press the key and the 1008a will begin a 30 second countdown During this time th...

Страница 9: ...should only be used when necessary Pressing the key will cause the 1008a to display MAX This indicates the Maximum CO2 and Temperature measured is displayed Press the key again and the 1008a will display MIN This indicates the Minimum CO2 and Temperature measured is displayed Press the key again and the 1008a will display AVG This indicates the Average CO2 and Temperature measured is displayed Pre...

Страница 10: ...el in ppm 4 6 Setting CO2 Alarm Level key until the CO2 alarm screen is displayed 4 7 Ambient Air CO2 Reset The CO2 sensor can be reset at ambient level as needed This can be performed if the CO2 reading seems to be too high or low or just to ensure your 1008A is operating properly Note This does not take the place of a full factory calibration which is recommended once per year 1 Take the 1008A o...

Страница 11: ...ding every 10 min utes The log interval time is adjustable from 1 minute to 60 minutes in the fol lowing increments 1 2 3 5 10 20 30 40 50 60 minutes A maximum of 50 readings can be logged 2 Use the 3 Once the logging interval is set press the key and the 1008a will return to the main display and LOG will flash indicating the logging function is active The1008a will beep each time a reading has be...

Страница 12: ...ware on your PC and open it Connect the 1008a to the PC using the USB cable Run the software and select 1008a when prompted Click on the connect to PC button in the software window The software can be used to retrieve logged data and for real time monitoring COM port setting is Baud rate 19200 Parity None Data Bits 8 Stop Bit 1 1 Press the key LOG 01 and the logged CO2 and temperature reading will...

Страница 13: ... with annunciators and backlight CO2 Alarm Audible and visual selectable level factory default off Operating Temperature Humidity CO and CO2 14 F to 122 F 10 C to 50 C All Other Function 4 F to 140 F 20 C to 60 C Humidity 15 95 non condensing Storage Temperature 4 F to 140 F 20 C to 60 C Power supply 3 AA battery 4 5V AC DC adapter 5Vout Center positive Battery Life 40 hours typical without backli...

Страница 14: ...he screw holding down the battery cover located under the tilt stand 3 Lift the tilt stand up and remove the battery cover 4 Replace the batteries 3 x AA Alkaline and install the cover and tighten the screw 8 2 Service To obtain warranty and non warranty performance or maintenance on your analyzer Include with the product your name address phone number writ ten description of the problem and proof...

Страница 15: ...lth 2009 2 American Society of Heating Refrigerating and Air Conditioning Engineers 3 Occupational Safety and Health Administration Permissible Exposure Limit this level is a time weighted average and is an enforceable standard that must not be exceeded during any eight hour work shift of a 40 hour work week 4 American Conference of Governmental Industrial Hygienist Threshold Limit Value this leve...

Страница 16: ...eturn your instrument to TPI See section 9 2 for instruc tions on returning your meter Temperature Sensor Error If the temperature sensor fails to initialize or is faulty the 1008a will display an error code Try turning the 1008a off and on again If it displays the error code again the 1008a is in need of service Please return your instrument to TPI See section 9 2 for instruc tions on returning y...

Отзывы: