![TPI Corporation Fostoria OCH Series Скачать руководство пользователя страница 5](http://html.mh-extra.com/html/tpi-corporation/fostoria-och-series/fostoria-och-series_manual_1146382005.webp)
Date: 08-01-07
Rev. Date: 10-28-20
Level 07
ECO 1-7673
OIPM P/N: 8303
Page 5 of 8
QUARTZ TUBE INSTALLATION
ELECTRIC SHOCK HAZARD
• Serious injury or death may occur.
• Disconnect from electrical supply
before installing or servicing this
heater.
•
Reflector end caps must be installed
prior to powering the unit; refer to
note 3.
Install heater so that the quartz tubes are horizontal.
Failure to do this may cause the heating element
within the tube to sag and cause premature burnout.
Each heater is equipped with two hi-temperature
silicone lead wires and a ground termination.
Make
sure power source conforms to the heater requirements.
Use only Fostoria quartz tubes.
1.
Insert quartz tube in the “L”-shaped slots in heater
housing.
2.
On each end of the quartz tube, place (1) lead
wire ring terminal, (1) lock washer and (1) hex nut
on the threaded stud and
tighten securely
(see
image below). Lock washers and hex nuts are
provided in hardware package.
NOTE – Use a second wrench to hold the inner hex nut
in place while tightening the outer hex nut. Failure to
securely tighten this connection will cause the element
to fail prematurely.
3.
Attach reflector end caps to both ends of housing
using the (4) screws provided in hardware package.
QUARTZ TUBE
LOCK WASHER
RING TERMINAL
HEX NUT
HEATER INSTALLATION
MINIMUM INSTALLATION CLEARANCES
These heaters MUST be installed as follows:
• 12 inches minimum from a vertical surface
• 72 inches minimum from ANY combustible
material
• 3 inches minimum from the ceiling
• 36 inches minimum from other heaters
FIRE HAZARD
• Serious injury or death may
occur.
• Read and follow clearances
shown in box at left for ALL OCH
series heater installations.
• Do not use inside residences.
NOTE: For optimum spot heating performance, it is recommended that the distance from the floor should be
approximately 7 to 9 feet for the OCH-46 model, and 8 to 10 feet for OCH-57 models.