The FES series heaters are designed to circulate room air across its heating elements to gradually  

increase room temperature.  The best performance results will be obtained when using these heaters 

in smaller, confined spaces with low ceilings.

Operation of these heaters is accomplished using the thermostat and fan switch.

You have the option to use the fan only*, or the fan and heating elements together.  Position the fan 

switch  to the “fan” position to circulate room air with no heating.  Move the switch into the “heat” 

position for control of fan and elements with the thermostat. Maximum heating is obtained with knob  

turned fully clockwise**.  

 

 

This heater is equipped with an automatic fan purge that eliminates residual heat after the 

heating cycle . Allow the heater to fully purge before disconnecting power to the heater. This will 

eliminate the possibility of cycling the heater on the limit control.

 *The thermostat has a preset range of 40oF, there will be no “fan only” function as the  

thermostat is always calling for heat.

 **Setting the thermostat to high heat versus low heat does not make the unit operate at a    

higher temperature.  It simply raises the temperature necessary to satisfy the thermostat.  

The unit will run longer to try to satisfy a higher thermostat setting.

Note:  ALL FES models are equipped with an internal over temperature limit designed to protect your 

heater if a restricted airflow condition occurs.  This limit device will completely shut down the heating 

elements if the temperature limit is reached.  The limit must be manually reset when the unit cools.

The reset button is marked and located on the side of the control box near the thermostat knob 

on the 45kW models and the opposite side for the 60 kW models.

 

WARNING:

• 

Do not use outdoors or where flammable gases or liquids are stored.

•  Do not use as a residential comfort heater.

•  Keep portable heater 3ft. minimum from all combustible materials at all times.

•  Do not modify heater in any way.

•  Do not provide power to heater when unit is near standing water.

•  Only use handle to move heater.

•  Do not touch heater housing when in use.

•  Do not allow feeder cable to contact combustible materials.

OPERATING INSTRUCTIONS

Содержание FES-4548-3

Страница 1: ...53 585 BTU FES 6048 3 04915302 60 480 3 73 5 2500 CFM 204 780 BTU FES 6057 3 04915402 60 575 3 61 3 2500 CFM 204 780 BTU Description Fostoria portable electric salamander heaters provide clean odor free fan forced heat They are designed to circulate room air continously gradually heating a confined space The best results will be obtained when using these heaters in smaller insulated spaces Feature...

Страница 2: ...er to these heaters MUST have a ground bus or ground pole that is securely bonded to earth ground Connect green ground conductor on feeder cable or cable kit to grounding lug on heaters Comply with ALL local electrical codes and the National Electric Code NFPA70 when providing electrical power to these heaters FES 4548 3 WIRING DIAGRAMS LTB GRD E E E E E E E E CC2 ELEMENTS WIRED WYE CAPACITOR POWE...

Страница 3: ...R TERMINAL BLOCK BTB LINE TERMINAL BLOCK LTB GROUND LUG GND 480 VAC ORANGE BLACK YELLOW SPLICE YELLOW BLUE GREEN SPLICE FAN DELAY OFF 3 1 H H BRN WHT BLACK YELLOW SPLICE YELLOW BLUE GREEN FLANGED INLET RECEPT FIR MOTOR CONTACTOR SPLICE POWER SUPPLY BROWN FAN HEAT TRANSFORMER XFMR CONTROL TERMINAL BLOCK CTB HTCO Limit Control HEATING ELEMENT E BLOWER MOTOR B CONTROLLING CONTACTOR CC FACTORY WIRING ...

Страница 4: ... WHT BLACK WHITE YELLOW BLUE TRANSFORMER XFMR CONTROL TERMINAL BLOCK CTB HTCO Limit Control HEATING ELEMENT E BLOWER MOTOR B CONTROLLING CONTACTOR CC FACTORY WIRING WIRING DIAGRAM LEGEND THERMOSTAT STAT BLOWER TERMINAL BLOCK BTB LINE TERMINAL BLOCK LTB GROUND LUG GND FUSES CC1 E E E E E E E E E E E ELEMENTS WIRED WYE CONTACTOR COILS CC2 CAPACITOR XFMR FUSES GND BLOWER MOTOR STAT HTCO CC2 ...

Страница 5: ...o fan only function as the thermostat is always calling for heat Setting the thermostat to high heat versus low heat does not make the unit operate at a higher temperature It simply raises the temperature necessary to satisfy the thermostat The unit will run longer to try to satisfy a higher thermostat setting Note ALL FES models are equipped with an internal over temperature limit designed to pro...

Отзывы: