TPI Corporation FES-4548-3 Скачать руководство пользователя страница 1

ECO 1-7575   

REV. LEVEL: D  

REV. DATE: 10-25-2019  

FORM:8992 

 

1 OF 5

MODEL FES-4548-3

MODEL FES-4557-3

MODEL FES-6048-3

MODEL FES-6057-3

PORTABLE ELECTRIC SALAMANDER

INSTALLATION 

INSTRUCTIONS

IMPORTANT SAFETY INFORMATION INSIDE

•  Serious injury or death possible.

•  Read, understand, and follow all safety information and instructions in this manual before using or  

servicing this product.

•  Retain these instructions for future reference.

SPECIFICATIONS

Model

Part Number

kW

Volts

Ph

Amps

Fan 

Output

Heat

Output

FES-4548-3

08722202

45

480

3

55.4

2200 CFM

153,585 BTU

FES-4557-3

04874002

45

575

3

46.2

2200 CFM

153,585 BTU

FES-6048-3

04915302

60

480

3

73.5

2500 CFM

204,780 BTU

FES-6057-3

04915402

60

575

3

61.3

2500 CFM

204,780 BTU

Description

 - Fostoria portable electric salamander heaters provide clean, odor-free, fan-forced heat.  They are 

designed to circulate room air continously; gradually heating a confined space.  The best results will be obtained 

when using these heaters in smaller, insulated spaces.  Features include a safety-yellow enclosure with front and 

rear safety screens; reliable steel finned heating elements; a high-limit temperature switch with manual reset; 

an automatic thermostat control; fan switch; and a long-life motor and fan assembly with sealed bearings.  The 

portable (FES) models come mounted on a four-wheeled cart with wheels designed to be easily pushed or pulled 

over uneven surfaces.

Содержание FES-4548-3

Страница 1: ...53 585 BTU FES 6048 3 04915302 60 480 3 73 5 2500 CFM 204 780 BTU FES 6057 3 04915402 60 575 3 61 3 2500 CFM 204 780 BTU Description Fostoria portable electric salamander heaters provide clean odor free fan forced heat They are designed to circulate room air continously gradually heating a confined space The best results will be obtained when using these heaters in smaller insulated spaces Feature...

Страница 2: ...er to these heaters MUST have a ground bus or ground pole that is securely bonded to earth ground Connect green ground conductor on feeder cable or cable kit to grounding lug on heaters Comply with ALL local electrical codes and the National Electric Code NFPA70 when providing electrical power to these heaters FES 4548 3 WIRING DIAGRAMS LTB GRD E E E E E E E E CC2 ELEMENTS WIRED WYE CAPACITOR POWE...

Страница 3: ...R TERMINAL BLOCK BTB LINE TERMINAL BLOCK LTB GROUND LUG GND 480 VAC ORANGE BLACK YELLOW SPLICE YELLOW BLUE GREEN SPLICE FAN DELAY OFF 3 1 H H BRN WHT BLACK YELLOW SPLICE YELLOW BLUE GREEN FLANGED INLET RECEPT FIR MOTOR CONTACTOR SPLICE POWER SUPPLY BROWN FAN HEAT TRANSFORMER XFMR CONTROL TERMINAL BLOCK CTB HTCO Limit Control HEATING ELEMENT E BLOWER MOTOR B CONTROLLING CONTACTOR CC FACTORY WIRING ...

Страница 4: ... WHT BLACK WHITE YELLOW BLUE TRANSFORMER XFMR CONTROL TERMINAL BLOCK CTB HTCO Limit Control HEATING ELEMENT E BLOWER MOTOR B CONTROLLING CONTACTOR CC FACTORY WIRING WIRING DIAGRAM LEGEND THERMOSTAT STAT BLOWER TERMINAL BLOCK BTB LINE TERMINAL BLOCK LTB GROUND LUG GND FUSES CC1 E E E E E E E E E E E ELEMENTS WIRED WYE CONTACTOR COILS CC2 CAPACITOR XFMR FUSES GND BLOWER MOTOR STAT HTCO CC2 ...

Страница 5: ...o fan only function as the thermostat is always calling for heat Setting the thermostat to high heat versus low heat does not make the unit operate at a higher temperature It simply raises the temperature necessary to satisfy the thermostat The unit will run longer to try to satisfy a higher thermostat setting Note ALL FES models are equipped with an internal over temperature limit designed to pro...

Отзывы: