background image

DANGER

Never use the inverter in a location that is wet or damp. Never expose the inverter to rain, snow, 

water spray or standing water while in use. Protect the inverter from all hazardous weather conditions. 

Moisture or ice can cause a short circuit or other malfunction in the electrical circuit.

Never operate the inverter in an enclosed area. Engine exhaust contains carbon monoxide. Only

operate the inverter outside and away from windows, doors and vents.

WARNING

Voltage produced by the inverter could result in death or serious injury.

• Never operate the inverter in rain or a flood plain unless proper precautions are taken to avoid being

subject to rain or a flood.

• Never use worn or damaged extension cords.

• Always have a licensed electrician connect the inverter to the utility circuit.

• Never touch an operating inverter if the inverter is wet or if you have wet hands.

• Never operate the inverter in highly conductive areas such as around metal decking or steel works.

• Always use grounded extension cords. Always use three-wire or double-insulated power tools.

• Never touch live terminals or bare wires while the inverter is operating.

• Be sure the inverter is properly grounded before operating.

WARNING

Gasoline, gasoline vapors & liquid petroleum gas (LPG) are extremely flammable and explosive under 

certain conditions.

• Always refuel the generator outdoors, in a well-ventilated area.

• Never remove the fuel cap with the engine running.

• Never refuel the inverter while the engine is running. Always turn engine off and allow the generator to

cool before refueling.

• Only fill fuel tank with gasoline.

• Keep sparks, open flames or other forms of ignition (such as match, cigarette, static electric source)

away when refueling.

• Never overfill the fuel tank. Leave room for fuel to expand. Overfilling the fuel tank can result in a

sudden overflow of gasoline and result in spilled gasoline coming in contact with HOT surfaces.

Spilled fuel can ignite. If fuel is spilled on the inverter, wipe up any spills immediately. Dispose of rag

properly. Allow area of spilled fuel to dry before operating the inverter.

• Wear eye protection while refueling.

• Never use gasoline as a cleaning agent.

• Store any containers containing gasoline in a well-ventilated area, away from any combustibles or

source of ignition.

• Check for fuel leaks after refueling. Never operate the engine if a fuel leak is discovered.

WARNING

Never operate the inverter if powered items overheat, 

electrical output drops, there is sparking, flames or smoke 

coming from the inverter, or if the receptacles are damaged.

Never use the inverter to power medical support equipment.

Always remove any tools or other service equipment used 

during maintenance from the inverter before operating.

NOTICE

Never modify the inverter.

Never operate the inverter if it 

vibrates at high levels, if engine 

speed changes greatly or if the

engine misfires often.

Always disconnect tools or 

appliances from the

inverter before starting.

GENERAL SAFETY RULES

SAFETY

4

Содержание Di4000

Страница 1: ...TPE Di4000 Open Frame Digital Inverter Generator 3500 Running Watts 4000 Peak Watts INVERTER GENERATOR...

Страница 2: ...rt or killed Model Number Running Watts Peak Watts Gasoline Tank Size G Rated Speed RPM Ignition Type Spark plug Engine Disp cc Stroke X Bore Oil Capacity L Oil Type Fuel Type TPE Di4000 3500 4000 10L...

Страница 3: ...ER Indicates a hazardous situation which if not avoided will result in death or serious injury WARNING Indicates a hazardous situation which if not avoided could result in death or serious injury CAUT...

Страница 4: ...emove the fuel cap with the engine running Never refuel the inverter while the engine is running Always turn engine off and allow the generator to cool before refueling Only fill fuel tank with gasoli...

Страница 5: ...ne has started Oil Fill Plug Dipstick Must be removed to add and check oil Muffler and Spark Arrestor Avoid contact until the engine is cooled down The spark arrestor prevents sparks from exiting the...

Страница 6: ...ease the mode button to toggle between Voltage Frequency Total Hour Meter and Run Maintenance Timer Frequency in hertz Lifetime run hours Run Maintenance Voltage The Run Maintenance Timer displays the...

Страница 7: ...ctrician for local grounding requirements Neutral Floating The generator stator winding is isolated from the frame and from the AC receptacle ground pin Consult with your local municipalities for your...

Страница 8: ...of cords are highly variable Always check with local regulations and a licensed electrician prior to installing or connecting an electrical appliance Extension Cord Wire Gauge Size AWG 8 TRANSPORTING...

Страница 9: ...ermanently damage internal engine components The engine is equipped with a low oil shutdown switch If the oil level becomes low the engine may shut down and not start until the oil is filled to the pr...

Страница 10: ...ons Before attempting to start the inverter verify the following The engine is filled with engine oil see Engine Oil Correct Level The inverter is situated in a proper location see Location Selection...

Страница 11: ...ed up to operating temperature 1 To turn on the efficiency mode press the switch to the ON position 2 If no load is present the inverter RPM will drop down to an idle speed 3 As a load is applied the...

Страница 12: ...ch prior to performing any maintenance procedure Internal pressure can build in the engine crankcase while the engine is running Removing the oil fill plug dipstick while the engine is hot can cause e...

Страница 13: ...ure 8 7 Using the supplied oil funnel slowly add engine oil to the engine Stop frequently to check the oil level and avoid overfilling 8 Continue to add oil until the oil is at the correct level then...

Страница 14: ...l of hazardous materials Consult local authorities or reclamation facility MAINTENANCE AIR FILTER MAINTENANCE WARNING Never use gasoline or other flammable solvents to clean the air filter Use only ho...

Страница 15: ...l authorities or reclamation facility Cleaning the Air Filter Continued NOTICE Never dispose of soap cleaning solution used to clean the air filter by dumping the solution into a sewer on the ground o...

Страница 16: ...arrestor band clamp off the spark arrestor screen 7 Pull the spark arrestor screen off the muffler exhaust pipe SPARK PLUG MAINTENANCE The spark plug must be checked and cleaned after every 100 hours...

Страница 17: ...e or 2 spark from an electric appliance MAINTENANCE Figure 20 Remove spark arrestor 8 Using a wire brush remove any dirt and debris that may have collected on the spark arrestor screen 9 If the spark...

Страница 18: ...er for any storage 1 Clean the inverter as outlined in Cleaning the Inverter 2 Siphon all gasoline from the fuel tank as best as possible 3 Start the engine and allow the inverter to run until all the...

Страница 19: ...ssages and make sure fuel shut off is ON 3 Dirty air filter 3 Check and clean the air filter 4 Low oil level shutdown switch is preventing the unit from starting 4 Check oil level and add oil if neces...

Страница 20: ...this warranty Warranty excludes consumable parts for example wheels bearings The benefits provided under this warranty are in addition to other rights and remedies which are available to you under law...

Отзывы: