19

Gigabit Smart Switch

Connection

Verify Installation

212 

After completing the installation, please verify the following items:

There are 5~10cm of clearance around the sides of the device for ventilation and 

 

the air flow is adequate.

The voltage of the power supply meets the requirement of the input voltage of the device.

 

The power socket, device and rack are well grounded.

 

The device is correctly connected to other network devices.

 

Power On

212 

Plug in the negative connector of the provided power cord into the power socket of the 
device, and the positive connector into a power outlet as the following figure shown.

Connecting to Power Supply

Figure 4-3  

Note:

 The figure is to illustrate the application and principle. The power plug you get 

from the package and the socket in your situation will comply with the regulation in 

your country, so they may differ from the figure above.

Initialization

214 

After the device is powered on, it begins the Power-On Self-Test. A series of tests run 
automatically to ensure the device functions properly. During this time, its LED indica-
tors will respond as follows:

The Power/PWR LED indicator will light on all the time.

 

After keeping off for several seconds, the LED indicators of all the ports will flash 

 

momentarily and then turn off again after the initialization.

The System/SYS LED indicator will flash, which represents a successful initialization.

 

Содержание TL-SG2216

Страница 1: ...Installation Guide Gigabit Smart Switch TL SG2216 TL SG2424 TL SG2424P TL SG2452 Enterprise Networking Solution ...

Страница 2: ...ment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense This device complies w...

Страница 3: ...chapter illustrates how to do the physical connec tion of the Switch Chapter 5 Configuration This chapter instructs you to configure the Switch via Web Interface and CLI commands Appendix A Troubleshooting Appendix B Hardware Specifications Appendix C Technical Support Audience This Installation Guide is for Network Engineer Network Administrator Conventions Due to the similarity in structure of t...

Страница 4: ...ection 12 3 1 Cabling Reasonably 12 3 2 Connect to Ground 14 3 3 Equipotential Bonding 15 3 4 Use Lightning Arrester 16 Chapter 4 Connection 18 4 1 Ethernet Port 18 4 2 SFP Port 18 4 3 Verify Installation 19 4 4 Power On 19 4 5 Initialization 19 Chapter 5 Configuration 20 5 1 Configure the Switch via GUI 20 5 2 Configure the Switch Using CLI 21 Appendix A Troubleshooting 23 Appendix B Hardware Spe...

Страница 5: ... excellent performance and is friendly to manage which can fully meet the need of the users demanding higher networking performance TL SG2424P Smart PoE Switch is also a Power Sourcing Equipment PSE All the Auto Negotiation RJ45 ports on the switch support Power over Ethernet PoE function which can automatically detect and supply power with those powered devices PDs complying with IEEE 802 3af and...

Страница 6: ...e corresponding port but no activity Flashing The corresponding port is transmitting or receiving data Off There is no device linked to the corresponding port 1000Mbps On A 1000Mbps device is connected to the corresponding port Off A 10 100Mbps device or no device is connected to the corresponding port 10 100 1000Mbps RJ45 Port Designed to connect to the device with a bandwidth of 10Mbps 100Mbps o...

Страница 7: ... port LED is indicating the data transmission rate LED Status Indication Power On The Switch is powered on Off The Switch is powered off or power supply is abnormal Flashing Power supply is abnormal System Flashing The Switch works properly On Off The Switch works improperly 10 100 1000Mbps Green On A 1000Mbps device is connected to the corresponding port but no activity Flashing Data is being tra...

Страница 8: ...signed to install the SFP module TL SG2424P Switch features 4 SFP transceiver slots that are shared with the associated RJ45 ports The associated two ports are referred as a Combo port which means they cannot be used simultaneously otherwise only SFP port works The front panel of TL SG2452 is shown as the following figure SFP Port Reset 10 100 1000Mbps RJ45 Port 49 30 32 34 36 38 40 42 44 46 48 2 ...

Страница 9: ... this button for five seconds or above to reset the software setting back to factory default settings Port Feature Model 10 100 1000Mbps RJ45 Port SFP Port TL SG2216 16 2 TL SG2424 24 4 TL SG2424P 24 4 TL SG2452 48 4 Note For TL SG2216 TL SG2424 TL SG2424P when using the SFP port with a 100M module or a gigabit module you need to log on to the GUI Graphical User Interface of the Switch and configu...

Страница 10: ...ocket Rear Panel of TL SG2452 FFFFFFFFFFF Grounding Terminal The Switch already comes with lightning protection mechanism You can also ground the Switch through the PE Protecting Earth cable of AC cord or with Ground Cable For detailed information please refer to Chapter 3 Lightning Protection Power Socket Connect the female connector of the power cord here and the male connector to the AC Alterna...

Страница 11: ...se observe the following rules Safety Precautions Keep the power off during the installation Wear an ESD preventive wrist strap and make sure that the wrist strap has a good skin contact and is well grounded Use only the power cord provided with the Switch Make sure that the supply voltage matches the specifications indicated on the rear panel of the Switch Ensure the vent hole is well ventilated ...

Страница 12: ... prevent static electricity but too strong static electricity can cause deadly damage to the electronic elements on the internal circuit board To avoid the effect of static electricity on the operation of the Switch please attach much importance to the following items Dust the device regularly and keep the indoor air clean Keep the device well grounded and ensure static electricity has been transf...

Страница 13: ...ignal SPD Surge Protective Device when wiring outdoor Note For detailed lightning protection measures please refer to Chapter 3 Lightning Protection Installation Site S When installing the device on a rack or a flat workbench please note the following items The rack or workbench is flat and stable and sturdy enough to support the weight of 5 5kg at least The rack or workbench has a good ventilatio...

Страница 14: ...er of the device Feet Bottom of the Device Notch Desktop Installation FFFFFFFFFFF Rack Installation To install the device in an EIA standard sized 19 inch rack follow the instructions described below Check the grounding and stability of the rack 111 Secure the supplied rack mounting brackets to each side of the device with supplied 222 screws as illustrated in the following figure Rack mounting Br...

Страница 15: ...ase set 5 10cm gaps around the device for air circulation Please avoid any heavy thing placed on the device Please mount devices in sequence from the bottom to top of the rack and ensure a certain clearance between devices for the purpose of heat dissipation Installation ...

Страница 16: ...ould be buried and paved to the indoor through basement A piece of steel wire should be paved underground along the pipe and connected to the lightning protection terminal of the building for shielding Before connecting the cable to the device install a signal lightning arrester on the corresponding port When an aerial cable is set up the cable should be through a metal pipe 15m long at least befo...

Страница 17: ...rlapping Net Height H mm1 Down conductor 1000 300 PE 50 20 Service pipe 150 20 Compressed air pipe 150 20 Thermal pipe not wrapped1 500 500 Thermal pipe wrapped1 300 300 Gas pipe 300 20 The two diagrams below demonstrate parallel net length and parallel overlapping net height Note The above minimum net length height is required when metal raceway is not used If any requirements cannot be met you c...

Страница 18: ...age and over current of the device which is also a necessary measure to protect the body from electric shock In different environments the device may be grounded differently The following will instruct you to connect the device to the ground in two ways connecting to the grounding bar or connecting to the ground via the power cord Please connect the device to ground in the optimum way according to...

Страница 19: ...t the device to the ground via the PE Protecting Earth cable of AC power cord please make sure the PE Protecting Earth cable in the electrical outlet is well grounded in advance Equipotential Bonding 3333 Equipotential Bonding is the practice of intentionally electrically connecting all earthed systems to the same grounding grid or connecting the grounding grids of all the earthed systems together...

Страница 20: ...rester 3333 Power lightning arrester and signal lightning arrester are used for lighting protection Power lightning arrester is used for limiting the voltage surge due to a lightning If an outdoor AC power cord should be directly connected to the device please use a power lightning arrester Note Power lightning arrester is not provided with our product If needed please self purchase it Signal ligh...

Страница 21: ... a standard lightning arrester Install signal lightning arrester near the protected device and connect it to the ground via a shorter ground cable Ethernet Cable Equipotential Bonding Cable Grounding Terminal Signal Lightning Arrester Device Lighting Arrester Connection FFFFFFFFFFF Note Signal lightning arrester is not provided with our product If needed please self purchase it Lightning Protectio...

Страница 22: ...ociated RJ45 port will be disabled and cannot be used SFP Port SFP Module Inserting the SFP Module FFFFFFFFFFFF Note When using the SFP port with a 100Mbps module or a gigabit module you need to log on to the GUI Graphical User Interface of the Switch and configure its corresponding Speed and Duplex mode on Switching Port Port Config page For 100Mbps module please select 100MFD while select 1000MF...

Страница 23: ... following figure shown Connecting to Power Supply FFFFFFFFFFFF Note The figure is to illustrate the application and principle The power plug you get from the package and the socket in your situation will comply with the regulation in your country so they may differ from the figure above Initialization 4444 After the device is powered on it begins the Power On Self Test A series of tests run autom...

Страница 24: ... subnet addresses of the Switch The IP address is 192 168 0 x x is any number from 2 to 254 Subnet Mask is 255 255 255 0 For the detailed instructions as to how to do this please refer to Appendix B in the User Guide on the Resource CD Enter admin for the default User Name and Password both in lower case letters 222 Then click the Login button or press the Enter key Login FFFFFFFFFFFF After a succ...

Страница 25: ...and access the CLI by Logging on to the Switch remotely by a Telnet connection through an Ethernet port To log on to the switch by a Telnet connection please take the following steps Make sure the switch and the PC are in the same LAN 111 Click Start 222 Run to open the Run window Open the Run window FFFFFFFFFFFF Configuration ...

Страница 26: ... 5 and click OK 333 Run Window FFFFFFFFFFFF Type telnet 192 168 0 1 in the command prompt shown as Figure 5 6 and press the 444 Enter button Connecting to the Switch FFFFFFFFFFFF Note TL SG2452 is unaccessible through Telnet Connection so that no configuration can be made by using CLI ...

Страница 27: ...t is normal Make sure the voltage of the power supply meets the requirement of the 222 input voltage of the Switch What could I do if I could not access the web based configuration QQQQ page You are recommended to check the following items Check every port LED on the Switch and make sure the cable is installed 111 properly Try another port on the Switch and make sure the cable meets the 222 requir...

Страница 28: ... maximum 100m1 100Base TX 2 pair UTP STP of Cat 5 or above maximum 100m1 100Base FX MMF or SMF SFP Module Optional1 1000Base T 4 pair UTP STP of Cat 5 Cat 5e and Cat 6 or above maximum 100m1 1000Base X MMF or SMF SFP Module Optional1 LEDs TL SG2216 TL SG2424 Power System 1000Mbps Link Act TL SG2424P Power System Speed Port Status LED PoE PoE Max TL SG2452 PWR SYS 10 100 1000Mbps Operating Temperat...

Страница 29: ... link com Service time 24hrs 7 days a week Australia New Zealand Tel AU 1300 87 5465 NZ 0800 87 5465 E mail support au tp link com Australia support nz tp link com New Zealand Service time 24hrs 7 days a week Malaysia Tel 1300 88 875 465 1300 88TP LINK Email support my tp link com Service time 24hrs 7 days a week Turkey Tel 444 1925 Turkish Service E mail support tr tp link com Service time 09 00 ...

Страница 30: ... Monday to Friday 09 00 to 12 30 and 13 30 to 17 30 GMT 1 or GMT 2 Daylight Saving Time Russian Federation Tel 8 499 754 5560 8 800 250 5560 toll free call from any RF region E mail support ru tp link com Service time From 10 00 to 18 00 Moscow time Except weekends and holidays in Russian Federation Ukraine Tel 0800 505 508 E mail support ua tp link com Service time Monday to Friday 10 00 to 22 00...

Страница 31: ......

Страница 32: ...Website http www tp link com E mail support tp link com 7106504146 Rev 1 1 0 ...

Отзывы: