33
Motor
trouble
If the motor starts at the same time as the power is connected, the transistor must be
defective. (See item 1-4 Components.) Also, in case the motor does not work as
specified in its operation sequence, the blower motor or the motor controller must be
defective.
Ignition with an explosion
Re-igniting of the heater immediately after it has been extinguighed may be
accompanied with an explosive noise. Wait 20 minutes before re-igniting.
White smoke
Make sure the extension pipe joints are disconnected. Connect the extension pipes
correctly.
Odor
Make sure the igniter gasket or other gasket are not damaged and/or the screws of fuel
pump are not loosened.