Toyotomi TDE-16JI Скачать руководство пользователя страница 23

23

GB

DEHUMIDIFIER

environment humidity is equel to or higher than the selected humidity by 2%, 
compressor will restart once 3-minute compressor protection time over.

4.press  

button as follows

Press to set the desired fan speed. It can be adjusted between high speed and 
low speed.
 The QUIET indicator light (above the small fan icon) will turns on when you 
program the unit in low fan speed.
 The DAY fan indicator light (above the big fan icon) will turns on when you 
program the unit in high fan speed.
 

5. Press 

button can be timer setting

Press the button to program the time when the unit turns on and turns off. If 
you want to cancel the timer programming, press the button to adjust the time 
at 00, and press the button ,it will be circulate from 00-01-02……23-24.It is 
the programmed time to switch the machine. The programmed time will be 
cancelled when to switch compressor manually each time. The programmed 
time remains unchanged if the machine stops to wok due to water full or during 
defrosting 

6.Press 

 button. Turn on/off the Ionizer function.

OPERATION

4.  Turning the unit On:

After the unit is plugged in 

fi

 rst time, a buzzer will beep and the humidity 

indicator show the default humidity level at 60% with low fan speed.

Press   

button to start operation.

5.  Open the louver manually

Before operation starts, please check and make sure the louver has been 
opened .If the louver is closed, the unit may overheat.

Содержание TDE-16JI

Страница 1: ...EHUMIDIFIER SENTO Series TDE 16JI TDE 18JI TOYOTOMI Thank you for choosing TOYOTOMI Dehumidifier For the proper use of your dehumidifier kindly read this manual carefully before use and retain it for...

Страница 2: ...2 GR...

Страница 3: ...3 GR 5 12 30 12 20 45 Timer On Off...

Страница 4: ...4 GR TDE 16JI TDE 18JI 220 240V 50Hz 30 RH80 16 18 280 watt 390 watt 3 0 2 70 kg 11 11 6 x x 310 x 230 x 535 mm 30 80 5 35 1 2 3 4 5 6...

Страница 5: ...5 GR 7 8 9 10 11 12 13 14 15 16 17 18...

Страница 6: ...6 GR 19...

Страница 7: ...7 GR 1 Active Carbon...

Страница 8: ...8 GR LED 1 FULL 2 POWER 3 TIMER 4 SETTINGS 5 QUIET 6 DRY 7 ION 1 2 3 4 35 LO 5 95 HI A C D E...

Страница 9: ...9 GR 1 2 3 40 80 5 2 o 3 2 3 4 QUIET DRY 5 00...

Страница 10: ...10 GR 00 01 02 23 24 6 1 60 2 3...

Страница 11: ...11 GR FULL 1 2 1...

Страница 12: ...12 GR 2 3 TANK FULL 10mm...

Страница 13: ...13 GR 1 2 3 4 ACTIVE CARBON ACTIVE CARBON 2...

Страница 14: ...14 GR 1 2 3 Active Carbon 4...

Страница 15: ...15 GR full 35 5...

Страница 16: ...collection systems or contact the retailer where the product was purchased to return your used device they can recycle products safely KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE This owner s manual...

Страница 17: ...m to room Low Temperature Operation With Automatic Defrost When the unit is running under the condition of 5 room temperature 12 it will be stop to defrost for every 30 minutes When the unit is runnin...

Страница 18: ...e following safety precautions 1 Unplug the power supply cord before cleaning or storage 2 Do not submerge the unit in water of place the unit close to water 3 Do not set the unit close to heat genera...

Страница 19: ...ase of malfunction please turn off immediately the appliance take off the plug from the socket and call service 15 Do not use power strip or cord extensions 16 The appliance must be installed in accor...

Страница 20: ...20 GB DEHUMIDIFIER PRODUCT DIAGRAM FRONT REAR Control panel Louver Wheels Handle Air filter Water tank Supply cord Continuous drainage port...

Страница 21: ...21 GB DEHUMIDIFIER Other Parts 1 Activated carbon filter OPERATING INSTRUCTIONS LED INDICATORS 1 FULL Water full 2 POWER Power 3 TIMER Timer 4 SETTINGS Set 5 QUIET Low fan 6 DRY High fan 7 ION Ionizer...

Страница 22: ...environment humidity is higher than 95 it will show HI Push Button Functions A Power Push Button B Timer Push Button C Adjustable Humidity Push Button D Fan Speed Push Button E Ioniser Button OPERATIN...

Страница 23: ...ns off If you want to cancel the timer programming press the button to adjust the time at 00 and press the button it will be circulate from 00 01 02 23 24 It is the programmed time to switch the machi...

Страница 24: ...ply cord DRAINING THE COLLECTED WATER 1 Lightly press on the sides of the tank with both hands and pull out gently 2 Discard the collected water NOTE 1 DO not remove the float on the unit The water fu...

Страница 25: ...nds If the tank is not positioned properly the TANK FULL sensor will be activated and the dehumidifier will not operate Continuous Water Drainage The unit features a continuous drainage port Using a p...

Страница 26: ...it with warm water and a mild cleanser and dry thoroughly before re install it into its initial position 3 Attach the air filter Insert the filter into the unit in smoothly 4 Active Carbon filter sho...

Страница 27: ...er supply cord and secure it to the water tank 2 Discard any water left in the drainage tank 3 Clean the air filter 4 Store the unit upright in its original packaging to keep it free of dust Store in...

Страница 28: ...room above 35 or below 5 The protection device is activated and the unit cannot be started The dehumidi fying function doesn t work Is the air filter clogged Clean the air filter as instructed under...

Страница 29: ...29...

Страница 30: ...30 GB...

Страница 31: ...31 GB...

Страница 32: ...59 13 664 e mail info gedsa gr SERVICE SPARE PARTS CENTRAL KIFISSOU AV 6 122 42 EGALEO ATHENS TEL 003 0 210 53 86 490 FAX 003 0 210 53 13 349 This product is made in China 6 122 42 003 0 210 53 86 40...

Отзывы: