The  idea  behind  the  unit  is  to  dehumidify  all  season  even  if  it  is 
winter.  This  model  features  desiccant  instead  of  compressor. 
Accordingly this model is not affected by room temperature. Also, 
desiccant type dehumidifier does not use harmful gasses, so it can 
be said as environmentally friendly.
It dries the air so that you can stay comfortable even when it’s hu-
mid or rainy outside. Also your furnishings, fabrics and clothes are 
kept in good condition, and it is easy to dry your laundry and dry it 
quickly. Desiccant type is quieter than the compressor type, there-
fore  you  can  dry  the  laundry  at  night  and  it  will  be  dried  in  the 
morning. 

OPERATIONAL FEATURES

FEATURES
1.  COMPRESSOR LESS DEHUMIDIFIER

This  model  uses  desiccant  rotor  technology  and  is  environ-
mentally friendly with no harmful gasses & quiet in operation.

2.  POWER SELECTION

Turn the knob to select HIGH MODE (high heating power and 
high fan speed) or LOW MODE (low heating power and low fan 
speed).

3.  IONISER

When the unit is on, ioniser release negative ions from the air 
outlet.

4.  ANTI BACTERIAL FILTER

Nano-silver  embedded  in  the  filter  kills  bacteria  on  contact, 
improving the quality of air in your home or office.

1.  DESCRIPTION

 

Fig. A 

FRONT

 

 

A1 

Louver

 

 

A2 

Wide / Spot adjustable louver

 

 

A3 

Air outlet

 

 

A4 

Front panel

 

 

A5 

Power supply cord

 

 

A6 

Power plug

 

 

A7 

Operation panel

 

 

A8 

Water tank

 

 

A9 

Water gauge

 

Fig. B 

REAR

 

 

B1  Carrying handle

 

 

B2  Air intake grille (Pre-filter)

 

 

B3  Air intake

 

 

B4  Water outlet drain for continuous drain operation

 

Fig. C 

OPERATION PANEL

 

 

C1  Humidistat knob

 

 

C2  Hi / Low Power knob

 

 

C3  Ion / Running lamp

 

 

C4  Full / Check lamp

(Lights  up  when  the  bucket  is  full,  incorrectly  in-
stalled; the unit inclines, falls down or internal ther-
mal  protection  activates  when  being  misused  or 
overheated (see “TROUBESHOOTING”)

2.  SAFETY TIPS

IMPORTANT

  •  Read instruction carefully before operation.
  •  The  unit  should  be  operated  when  the  room  temperature  is 

between 1°C to 40°C.

  •  If  the  supply  cord  is  damaged,  it  must  be  replaced  by  the 

manufacturer, its service agent or similarly qualified persons in 
order to avoid a hazard.

  •  The  appliance  shall  be  installed  in  accordance  with  national 

wiring regulations.

  •  While  drying  the  clothes,  please  keep  clothing  at  a  safe  dis

-

tance  from  the  unit  to  prevent  water  from  dropping  onto  the 
unit.

WARNING

This appliance is intended for use in a domestic environment only. 
Any other use is not recommended by the manufacturer and may 
cause  fire,  electrical  shocks  or  other  injury  to  person  or  property. 
When using electrical appliances, basic safety precautions should 
always be followed:

  •  DO NOT operate the unit with a damaged cord or plug, 

after it malfunctions or has been dropped or damaged in 

any way. Return to an authorized service facility for ex

-

amination and repair.

  •  This unit should always be kept in an upright position to 

avoid any damage. Locate the unit on a flat stable sur

-

face.

  •  Check  the  household  voltage  to  ensure  it  matches  the 

units rated specification before operating.

  •  Ensure that the air inlets and outlets are not blocked or 

covered.

  •  DO NOT place the unit too close to curtains or other ob

-

jects -minimum distance 40cm.

  •  When  using  the  unit    to  speed  up  the  drying  of  wet 

clothes in the room, please keep the clothing at a safe 

distance  from  the  unit  to  prevent  water  from  dropping 

onto the unit.

  •  NEVER place anything on top of the unit and do not cov

-

er with any kind of material while in use.

  •  This  product  is  intended  for  domestic  and  light  office 

use ONLY and not for commercial, industrial or outdoor 

use.

  •  To  protect  against  electrical  shocks,  DO  NOT  immerse 

unit, plug or cord in water, or spray with liquids.

  •  ALWAYS unplug the unit when not in use or moving lo

-

cation.  To  disconnect  from  the  power  supply,  grip  the 

plug and pull from the power socket. NEVER pull by the 

cord.

  •  ALWAYS  empty  the  water  tank  before  storing  the  unit 

away. 

  •  Using  the  dehumidifier  in  front  of  a  warm  radiator  can 

result  in  the  dehumidifier  not  collecting  any  water  be

-

cause of the heat from the radiator.

  •  DO  NOT  run  power  cord  under  carpets,  rugs,  or  floor 

mats  of  any  kind.  Arrange  the  cord  away  from  areas 

where it may be tripped over

  •  NEVER operate or store the unit in direct sunlight.
  •  To repair the unit, take it to a qualified service engineer. 

Repairs  carried  out  by  unqualified  people  may  cause 

damage to the unit or injury to persons or property and 

void the warranty.

  •  Where possible, avoid the use of an extension cable as 

they may overheat and cause a risk of fire. Only use an 

extension cord after ensuring it is in perfect condition.

  •  DO NOT use the unit without the air filter and make sure 

that the filter is kept clean to avoid malfunction and in

-

validating the warranty.

  •  This  appliance  can  be  used  by  children  aged  from  8 

years  and  above  and  persons  with  reduced  physical, 

sensory or mental capabilities or lack of experience and 

knowledge  if  they  have  been  given  supervision  or  in

-

struction concerning use of the appliance in a safe way 

and understand the hazards involved.

  •  Children shall not play with the appliance.
  •  Cleaning  and  user  maintenance  shall  not  be  made  by 

children without supervision.

Содержание TD-ZM80

Страница 1: ...PTIE LUCHTONTVOCHTIGER DEUMIDIFICATORE CON COMPRESSORE AFFUGTER AF T RREMIDDELTYPE OPERATING MANUAL ENGLISH P 1 MANUAL D UTILISATION FRAN AIS P 5 BEDIENUNGSANLEITUNG DEUTSCH P 9 GEBRUIKSAANWIJZING NED...

Страница 2: ...A B E D C3 C4 C1 C2 D1 D2 D3 D4 D5 B1 B2 B3 B4 A1 A2 A3 A4 A5 A6 A9 A7 A8 E2 E3 E4 E5 E1 E6 E7 E8 C...

Страница 3: ...more than 50cm more than 40cm When louver closed more than 20cm When louver up Top more than 60cm more than 20cm more than 20cm G J I F F3 F2 F4 H1 H2 I1 I2 F1 H G1 B A...

Страница 4: ...cal shocks or other injury to person or property When using electrical appliances basic safety precautions should always be followed DO NOT operate the unit with a damaged cord or plug after it malfun...

Страница 5: ...the tank is not restored in the unit full tank lamp will light and cannot start operation 4 The tubing should be lead to the drain with no sharp bends E6 E7 E8 NOTE 1 The water tank must be in the co...

Страница 6: ...s Dehumidifier is blowing out warm air The dried air is past over a heating ele ment before it is blown into the room as part of the dehu midification pro cess This is normal a dehumidifier is not an...

Страница 7: ...y in basis to your nearest au thorized dealer or distributor of TOYOTOMI WHAT YOU MUST DO FOR WARRANTY SERVICE You must return the defective Product or part to any authorized dealer or distributor of...

Страница 8: ...NEW 10 15 TOYOTOMI CO LTD 5 17 Momozono cho Mizuho ku Nagoya 467 0855 Japan www toyotomi jp Printed in China...

Отзывы: