– 21 –
TROUBLESHOOTING GUIDE
POWER TIMER OPERATION
(green) (yellow) (green)
OFF
OFF
OFF
ON
OFF
ON
OR
OFF
OFF
FLASHING FLASHING
OFF
FLASHING
FLASHING
NO ROTATION or
SLOW ROTATION
SLIGHTLY TURN AND
STOP
NOT WARM ENOUGH
NOT WARM ENOUGH
NOISE
REPEATED "HEATING" AND "COOLING"
TAG FAN REPEATED
"OPERATION" AND "STOP"
TAG FAN REPEATED
"OPERATION" AND "STOP"
outdoor unit stops before
reaching set up temp.
POWER SUPPLY check the plug inserted into the outlet and the power supply
REMOTE CONTROLLER
FUSE (2.0A)
TRANSFORMER
PCB (RECEIVER & DISPLAY)
if the battery is dead or failure in remote controller
change to new one
check the fuse by eyes or cheak the electric continuity by tester
check the resistance by tester [see fig.1]
other than described above [See
「
how to operate
emergency operation test operation
」
]
OFF
OFF
OFF
FLASHING
OFF
OFF
FLASHING
ON
ON
SENSOR, TEMP. HEAT EXCHANGER
SENSOR, TEMP. ROOM
MOTOR, LOUVER
SETTING TEMPERATURE
SENSOR, TEMP. ROOM
COMPRESSOR
DROP VOLTAGE
BY DROP VOLTAGE
DEFECTIVE WIRING CONTACTS
EXCESS GAS
CAPACITOR, COMPRESSOR
COMPRESSOR LOCKING
OVERHEAT PREVENTION RELAY
WRONG WIRING CONNECTION
CUTTING OFF CT
COMPRESSOR BREAKDOWN
WRONG WIRING CONNECTION
PCB (MAIN CONTROLLER)
CAPACITOR, TAG FAN MOTOR
TAN FAN MOTOR
COMPRESSOR BREAKDOWN
PCB (MAIN CONTROLLER)
SENSOR, TEMP. HEAT EXCHANGER
TAN FAN MOTOR
CAPACITOR, TAN FAN MOTOR
check the resistance by tester [see table 1]
check the resistance by tester [see table 2]
check the resistance between two terminals [see fig.2,table 3]
adjust proper temperature in remote controller
check the resistance by tester [see table 2]
check by eyes
check proper voltage of power supply and use an exclusive power supply
check proper voltage of power supply and use an exclusive power supply
check the restarting operation of compressor, after passing 3 minutes
if the scale of the tester swings instantly to "zero
Ω
" and does
not move back to "infinity" , capacitor for compressor should
be replaced [NOTE.2]
other than described above
other than descrived above
check the pressure of refrigerant gas [see
「
performance curve diagram
」
]
if the scale of the tester swings instantly to "zero
Ω
" and does
not move back to "infinity", capacitor for TAG fan motor should
be replaced [NOTE.2]
other than described above
leak of gas, or cut off of overheat prevention relay
check the wiring order(NO ROTATION)
check the wiring order
change PCB (main controller)
check by eyes and clean it
check the voltage between blue and yellow in connector [see fig.3]
check the resistance by tester [see table 1]
after starts operation, if TAN fan rotate properly by hands,
capacitor should be replaced
check the resistance by tester [see table 2]
check the resistance by tester [see table 1]
check the blockage of air outlet of TAN
check the blockage of air inlet & air outlet of TAG
check the pressure of refrigerant gas [check
「
performance curve diagram
」
]
other than described above
check the pressure of refrigerant gas [check
「
performance curve diagram
」
]
check the blockage of air inlet & air outlet of TAG
check by eyes after power off. turn by hands and check noise
check by eyes around the pipes with any obstacles
if DC5V is achieved between black and brown portion of lead wiring of fan
motor, while no voltage of pulse between white and black wiring, then TAN
fan motor should be replaced
UNDER "POWER SAVE" MODE (NOTHING ABNORMAL)
check the voltage between 2 and 4 in terminals [see fig.5]
check the voltage between 2 and 4 in terminal [see fig.5]
check the current at wiring 1 by clamp meter [see fig.4]
OFF
OFF
REMOTE CONTROLLER
「
ON
」
"POWER LAMP" GREEN ON
LOUVER
「
OPEN
」
"OPERATION LAMP" GREEN ON
4-WAY VALVE ON
TAG FAN ROTATING
COMPRESSOR IS WORKING
OPERATING IN HEATING MODE
REMOTE CONTROLLER
「
OFF
」
TAN FAN STARTING
(HOT START MODE)
COMPRESSOR
TAN FAN STOP
TAG FAN
"OPERATION LAMP" OFF
"POWER LAMP" OFF
LOUVER
「
CLOSE
」
STOP
4-WAY VALVE (WITH COIL) OFF
NO
YES
NO
YES
NO
YES
NO
YES
NO
YES
NO
YES
NO
YES
[NOTE.1] If alarm "
" appears 15 sec. after main power on, PCB(MAIN CONTROLLER) is defective.
[NOTE.2] Measure the resistance by changing the pole of the tester by turns.
1
〜
4 Terminal Number on Terminal Block of TAN. (indoor unit)
★
[NOTE.1]
check the wiring of 3 and 4 in terminal
(not turning TAG fan)
FILTER IS CHOKED
SENSOR, TEMP. ROOM
SENSOR, TEMP. HEAT EXHANGER
PLACE OF INSTALLATION
PLACE OF INSTALLATION
EXCESS GAS
COMPRESSOR BREAKDOWN
SHORTAGE OF GAS
PLACE OF INSTALLATION
TANGENTIAL FAN
PIPE
TAN FAN MOTOR
WRONG WIRING CONNECTION
HEATING OPERATION
Содержание TAG-A20EW
Страница 40: ...51 TAG A20EW EXPLODED VIEW OUTDOOR UNIT 2 5 1 6 7 11 13 9 21 19 18 20 15 16 12 14 3 4 8 17 22 23 10...
Страница 41: ...52 EXPLODED VIEW OUTDOOR UNIT TAG A28EW 16 1 5 6 15 11 8 10 19 3 14 13 18 9 7 12 20 4 2 4 21 22 17...
Страница 42: ...53 TAG A32EW 16 1 5 6 15 11 8 10 19 3 14 13 18 9 7 12 20 4 2 4 21 22 17...
Страница 47: ...ISSUED JUL 2004 RA 20 1 Printed in Japan...