background image

Press this button, could select displaying the indoor setting temperature or indoor ambient

temperature.When the indoor unit firstly power on it will display the setting temperature,

if the temperature's displaying status is changed from other status to"    ",displays the

ambient temperature, 3s later or within 3s, it receives other remote control signal that will 

return to display the setting temperature. if the users haven't set up the temperature 

displaying status,that will display the setting temperature.

SLEEP:

9

Press this button, can select Sleep 1 (            ), Sleep 2 (           ),Sleep 3 (           ) and cancel the Sleep,

circulate between these, after electrified, Sleep Cancel is defaulted.
Sleep 1 is Sleep mode 1, in Cool, Dehumidify modes: sleep status after run for one hour, the main
unit setting temperature will increase 1

10

TEMP:

4

How to use the remote control to operate the unit

OPERATION INSTRUCTIONS

Sleep 3- the sleep curve setting under Sleep mode by DIY:

(1) Under Sleep 3 mode, press "Turbo" button for a long time, remote control enters into user individuation sleep

setting status, at this time, the time of remote control will display "1 hour ", the setting temperature "88" will

(2) Adjust "+" and "-" button, could change the corresponding setting temperature, after adjusted, press

"Trubo "button for confirmation;

(3) At this time, 1 hour will be automatically increased at the timer postion on the remote control, (that are 

(4) Repeat the above step (2)

̚

(3) operation, until 8 hours temperature setting finished, sleep 

curve setting finished, at this time, the remote control will resume the original timer display;

display the corresponding temperature of last setting sleep curve and blink (The first entering will display

according to the initial curve setting value of original factory);

"2 hours " or "3 hours " or "8 hours "), the place of setting temperature "88" will display the 

corresponding temperature of last setting sleep curve and blink;

temperature display will resume to original setting temperature.

Ɣ

Ɣ

Sleep3- the sleep curve setting under SLEEP mode by DIY could be inquired:

The user could accord to sleep curve setting method to inquire the presetting sleep curve, enter into user 

individuation sleep setting status, but do not change the temperature, press "Turbo" button directly for confirmation.

Note: In the above presetting or enquiry procedure, if continuously within10s, there is no button pressed, the

sleep curve setting within10s, there is no button pressed, the sleep curve setting status will be automatically

quit and resume to display the original displaying. In the presetting or enquiry procedure, press "ON/OFF"

button, "Mode" button, "Timer"button or "Sleep" button, the sleep curve setting or enquiry status will quit similarly.

Ɣ

Ɣ

ć

,setting temperature increased 2

ć

, the unit will run at this

setting temperature; In Heat mode: sleep status after run for one hour, the setting temperature will
decrease 1

ć

, 2 hours, setting temperature will decrease 2

ć

, then the unit will run at this setting

temperature.

Ɣ

Sleep 2 is sleep mode 2, that is air conditioner will run according to the presetting a group of sleep temperature curve.

P

ress this button to achieve the on and off of healthy and scavenging functions in operation status.

Press this button for the first time to start scavenging function;

LCD displays“     ”.  Press the  button for the  second time to start healthy and scavenging functions 
simultaneously;  LCD  displays“     ” and “     ” .  Press  this  button  for  the  third time to quit healthy 

and scavenging  functions  simultaneously.  Press  the  button  for the fourth time to start  healthy 

f
(This function is applicable to partial of models)

unction; LCD display “      ” . Press this button again to repeat the operation above. 

/

8

Содержание MUL-E09CON

Страница 1: ...Owner s Manual Residential Air Conditioners Thank you for choosing Residential Air Conditioners please read this owner s manual carefully before operation and retain it for future reference MODEL MUL...

Страница 2: ...es or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety Children should be supervised to...

Страница 3: ...switch 17 Room temperature sensor W VHQVHV WKH DLU WHPSHUDWXUH DURXQG WKH XQLW 15 Signal receiver W UHFHLYHV VLJQDOV IURP WKH UHPRWH FRQWUROOHU KHQ WKH XQLW UHFHLYHV D VLJQDO RX ZLOO KHDU a short bee...

Страница 4: ...mperature setting Press it to decrease temperature setting FAN Press it set swing angle QUIET SWING CLOCK X FAN TEMP TURBO SLEEP LIGHT Press it to set fan speed Press it to set Press it to set auto of...

Страница 5: ...on mode in accordance with the room temperature to make indoor room comfortable 3 This button is used for setting Fan Speed in the sequence that goes from AUTO FAN 1 4 3 2 5 Press this button to turn...

Страница 6: ...e of original factory 2 hours or 3 hours or 8 hours the place of setting temperature 88 will display the corresponding temperature of last setting sleep curve and blink temperature display will resume...

Страница 7: ...HEAT mode Press this button to activate deactivate the Turbo function which enables the unit to reach the preset temperature in the shortest time In COOL mode the unit will blow strong Press and butto...

Страница 8: ...them after 30 seconds If it still can t operate properly Notes replace the batteries Sketch map for replacing batteries Replacement of Batteries At unit OFF press MODE and buttons simultaneously to s...

Страница 9: ...UW WKH IURQW SDQHO LQWR WKH JURRYHV RI WKH XQLW SODFHV 3UHVV WKH FODZV RQ WKH ULJKW DQG OHIW RI WKH DLU ILOWHU GRZQ VOLJKWO then pull upward 3 Take off the Titanium Apatite Photocatalytic Air Purifyin...

Страница 10: ...U ILOWHUV PD UHVXOW LQ WURXEOHV DV GXVW ZLOO DFFXPXODWH inside the indoor unit I WKH GXVW GRHV QRW FRPH Rff easily wash them with neutral detergent thinned with lukewarm water then dry them up in the...

Страница 11: ...period Check 127 Check that the base stand and other fittings of the outdoor unit are not decayed or corroded Check that nothing blocks the air inlets and the outlets of the indoor unit and the outdoo...

Страница 12: ...nt temperature decreased its cooling capacity will increase or decrease by outdoor ambient temperature If the unit is running in COOL mode and in low temperature there will be frost formed on the heat...

Страница 13: ...iffuse cool air Clean the air filter every week for higher efficiency Close window and door while operating the unit to prevent leakage of cooled air to save energy Draw close curtains or close glass...

Страница 14: ...a long time cut off the power supply main switch Do not insert objects into the air inlet or outlet when the airconditioner is running as it may cause damage or personal injury Also pay special attent...

Страница 15: ...damaged check if breaker switch is still on Check if the power supply is in order Check if the timer switch is on or not Check if the preset temperature is too high Check if the sunlight shines direct...

Страница 16: ...nit installation drawings are met 2 both air intake and exhaust have clear paths met 3 the unit is not in the path of direct sunlight 4 the unit is away from the source of heat or steam 5 there is no...

Страница 17: ...gth is 2 5m in order to avoid noise from the outdoor unit and vibration Mechanical noise and vibration may occur depending on how the unit is installed and the environment in which it is used See the...

Страница 18: ...to check the water flows smoothly 100 Drain hose 100 150 Vinyl chloride drain pipe 50mm or more Reducer Must be no trap Do not touch water 16 INSTALLATION INSTRUCTIONS Installation of indoor unit Bori...

Страница 19: ...ings 2 tabs on each side 4 Remove the slit portions on the bottom frame and casings using nippers 5 Return by following the steps in reverse order 3 2 1 Casing Remove the pillar Casing Remove the pill...

Страница 20: ...it the flare nut on the pipe 4 Flare the pipe 5 Check that the flaring is properly made WARNING 1 DO not use mineral oil on flared part 2 Prevent mineral oil from getting into the system as this would...

Страница 21: ...0mm or larger Gas pipe Gas pipe insulstion Finising tape Inter unit wiring Liquid pipe Liquid pipe insulation Selection of copper and heat insulation materials When using commercial copper pipes and f...

Страница 22: ...int with the included insulation sheet making sure there are no gaps Refrigerant pipe Refrigerant pipe Refrigerant pipe Slit Slit Tape Auxiliary pipe Insulation sheet CAUTION 1 Insulate the joint of t...

Страница 23: ...stranded wires extensioncords or starburst connections as they may cause overheating electrical shock or fire 2 Do not use locally purchased electrical parts inside the product Do not branch the power...

Страница 24: ...of the pipe with flaring kit by fitting the flare nut on the pipe before flaring Set the die on the pipe so that pipe end is 0 5 mm above top of the die Check if the pipe end is even and pertectly ro...

Страница 25: ...pipe s end with flare tool Tighten both flare nuts into gas pipe and liquid pipe at the indoor unit with two holding spanners 1 4 1 4 1 4 MODEL PIPE SIZE INSTALLATION INSTRUCTIONS GAS PIPE TABLE MODE...

Страница 26: ...alled correctly and securely Has it been fixed firmly Have you done the refrigerant leakage test Does the unit drain well Is heat insulation sufficient Possible malfunction Situation The unit may drop...

Страница 27: ......

Страница 28: ...66129914235...

Отзывы: