4
5
MANUAL
A
INSTALLING THE HEATER
1
Carefully remove your heater from the box and check the contents.
In addition to the heater you also need to have:
a manual fuel pump
a transportation cap
these directions for use
Keep the bo and the packaging materials ( ig. A) for storage and/or
transportation.
2
Open the lid of the removable tank
and remove the piece of cardboard.
3
ill the removable tank as indicated in
Section B.
4
The floor should be firm and completely level. Reposition the heater, when it
is not level. Do not try to correct the situation by placing books or other
goods under the heater.
5
Insert the plug
into the all-socket (230 Volts - AC / 50 H ) and set the
correct time using the adjustment keys
(refer to Section C).
6
Your heater is now ready for use.
SET ALTITUDE
1
If the heater is used at a height of 800 m to 1300 m, use the altitude mode 1.
Push the altitude button
with thin rod like a clip and plug into the outlet
simultaneously. Then “
1
” will be shown on the display.
2
If the heater is used at a height of 1300 m to 1900 m, use the altitude mode
2. After setting the altitude mode 1, push the altitude button
with thin rod
and plug into the outlet simultaneouosly again. Then “
2
” will be shown on
the display.
3
S itch off the altitude mode by pressing the altitude button
and into the
outlet simultaneously after setting altitude mode 2. Then “
0
” will be shown
on the display and “ ” will be disappeared.
NOTE:
When the altitude mode 1 is set, the altitude mark “ ” is lit on the display.
When the altitude mode 2 is set, the altitude mark “ ” is blinking during
operation.
NOTE:
In the event of power failure or disconnection of heater, the altitude setting
will remain.
Do not use the heater at a height of over 1900 meters.
SWITCH THE VOLUME
This heater can be s itched the bu er sound volume. The initial setting is in
High level.
1
Push the SAVE key
and holding it do n for more than 3 seconds, then the
bu er sound volume is s itched from High to Lo .
2
Push the SAVE key
and holding it do n for more than 3 seconds again,
then the bu er sound volume is s itched from Lo to High.
NOTE:
The volume level is Lo and High only, but the alarm by safety device
sounds in High level.
NOTE:
When the heater has been unplugged or after a power failure, the volume
ill be the initial setting High.
A