2
SECTION B:
SAFETY TIPS FOR OPERATION
CAUTION: Heater and vent pipe system must be properly installed before operation. Please follow
instructions under “Installation”, Section F.
1. Never use any fuel other than Kerosene. NEVER USE GASOLINE. Use of gasoline
can lead to uncontrollable flames, resulting in destructive fire.
2. Due to high surface temperatures, keep heater away from children, furniture and
clothing while in operation (See Page 12).
3. To prevent abnormal operation and prolong heater life, be sure to perform routine
maintenance (See Pages 9).
4. Never store or transport fuel in other than a metal or plastic container that is (1)
acceptable for fuel and (2) clearly marked “KEROSENE”. Never store fuel in the
living space.
RIGHT
WRONG
GAS
KEROSENE
Kero-
sene
Danger
SECTION A:
SPECIFICATIONS
Model:
FR-700F
Heater Efficiency:
92.4% (1)
Heat Rating:
High - 7.00 kW (23,900 BTU/h)
Low - 1.75 kW ( 5,980 BTU/h)
Fuel Consumption:
High - 0.791 L/h
Low - 0.198 L/h
Fuel system:
External tank (2)
Fuel Type:
Kerosene only
Dimensions (W × H × D):
700 × 593 × 422 mm
Weight:
28 kg
Vent Pipe Hole:
70 ~ 80 mm diameter
Maximum Length of Vent Pipe System:
3 m, 3 bents or less
Electrical Rating:
220 Volts AC, 50 Hz
Preheat - 260 W
Burning - 45 W
(1) Heat and vaporized water are produced by the combustion process of this heater. This rating does not take into
account heat loss due to condensation of water vapor.
(2) External tank to be purchased from local suppliers.