Toyotomi FF-V30T Скачать руководство пользователя страница 1

VENTED HEATING SYSTEM

INSTALLATION AND OPERATION INSTRUCTIONS

IMPORTANT

READ AND UNDERSTAND INSTRUCTIONS BEFORE INSTALLING OR USING HEATER.

RETAIN INSTRUCTIONS FOR FUTURE REFERENCE. CHECK LOCAL CODES AND ORDINANCES FOR PERMITTED USE.

MODEL 

FF-V30T

CONTENTS

SECTION A:

Specifications ····························································· 2

SECTION B:

Safety Tips for Operation ·········································· 3

SECTION C:

Fuel Guide ·································································· 4

SECTION D:

Operation ··································································· 5

SECTION E:

Error Messages ························································ 10

SECTION F:

Installation ································································ 11

 FF-V30T (E)  07.11.8 11:17 AM  ページ 2

Содержание FF-V30T

Страница 1: ...ORE INSTALLING OR USING HEATER RETAIN INSTRUCTIONS FOR FUTURE REFERENCE CHECK LOCAL CODES AND ORDINANCES FOR PERMITTED USE MODEL FF V30T CONTENTS SECTION A Specifications 2 SECTION B Safety Tips for Operation 3 SECTION C Fuel Guide 4 SECTION D Operation 5 SECTION E Error Messages 10 SECTION F Installation 11 ...

Страница 2: ......

Страница 3: ... 540 300 mm Weight 15 kg Vent Pipe Hole 70 80 mm diameter Maximum Length of Vent Pipe System 3 m 3 bents or less Electrical Rating 230 Volts AC 50 Hz Preheat 270W Burning 33W Typical Room Size 2 35 120 m3 1 Heat and vaporized water are produced by the combustion process of this heater This rating does not take into account heat loss due to condensation of water vapor 2 Room size for which this hea...

Страница 4: ...peration and prolong heater life be sure to perform routine maintenance See Pages 9 4 Never store or transport fuel in other than a metal or plastic container that is 1 acceptable for fuel and 2 clearly marked KEROSENE Never store fuel in the living space 5 Operating Temperature Range Use heater within the range of temperatures indicated in the right figure Point A If outside temperature 18 C than...

Страница 5: ...when optional removable fuel tank is used ALWAYS Fill heater away from living quarters when heater is cool use siphon ALWAYS Watch fuel gauge to avoid overfilling heater How to Store It ALWAYS Store in a clean container clearly marked KEROSENE ALWAYS Store away from direct sunlight heat sources or extreme temperature changes NEVER In a glass container or one that has been used for other fuels NEVE...

Страница 6: ...lates the room temperature uses very little fuel and electricity and has options for automatic or manual operation This section provides all the information required for the operation of the Vented Heating System All specified operating procedures must be carried out in the order in which they are described SECTION D OPERATION 5 ...

Страница 7: ... Information display Displays the clock set temperature room temperature and error codes 4 SAVE button Allows you to limit the temperature When this function is activated the heater will automatically switch off and on again 5 TIMER button Allows you to switch on the heater automatically at a preset time 6 CHILDPROOF LOCK button Can be used to prevent children accidentally changing the heater sett...

Страница 8: ...s no need to press any longer 6 Check the removable tank fuel gauge while filling the tank Stop filling by loosening the switch button on top of the pump turn anti clockwise once the gauge indicates that the tank is full Never overfill the tank especially not when the fuel is very cold fuel expands when it heats up 7 Let the remaining fuel in the pump flow back into the can and carefully remove th...

Страница 9: ... higher setting and the button on the left 왖hour to lower the temperature Press once to increase the value one step After approximately 10 seconds the light will stop blinking and setting will belocked The available temperature settings range from10 C minimum to 32 C maximum When the heater has been unplugged or after a power failure the temperature will reset to the factory setting of 20 C The op...

Страница 10: ...rect sunlight draughts or the warm air flowing out of the heater 7 Childproof lock The childproof lock can be used to prevent children accidentally changing the heater settings When the heater is burning and the childproof lock is on the heater can only be switched off Other functions are blocked then If the heater has already been switched off the childproof lock also prevents accidental ignition...

Страница 11: ...ainst a hard surface Never clean it with water 3 Reinstall the fuel filter into the heater We recommend that you remove dust and stains in time with a damp cloth because otherwise these may cause stains that are hard to remove Do not remove any heater components yourself Always contact your dealer for repairs When the power cord is damaged it may only be replaced by an authorized fitter Use a new ...

Страница 12: ...etting Room temperature is higher than 35 C Position of room temperature sensor is not correct Room temperature is lower than 10 C Room thermistor malfunction or disconnected WHAT TO DO Re ignite the heater Contact your dealer Contact your dealer Contact your dealer Clean the air filter and remove dust Contact your dealer Contact your dealer Contact your dealer Refill removable tank Set the timer ...

Страница 13: ...e gaps in the manner stipulated in the instructions in the manual Recommended tool kit 1 Crosshead screwdriver 2 Steel tape measure 3 Felt tip pen or pencil 4 Cement for exterior use 5 Electric drill clockwise and anti clockwise recommended 6 Hole cutting saw jig saw or other tools suitable forsawing a hole of 70 80 mm for the exhaust pipe 7 Long drill 8 Standard screwdrivers 9 Volt Ohmmeter 10 Sp...

Страница 14: ...lation kit from the packaging C Remove the heater from the packaging D Remove the plastic bag containing the parts E Remove the exhaust pipe from the bottom of thebox F Check that all parts are present Only the standard feed and exhaust system is supplied with the heater Fig 1 Gaps heater exhaust pipe FF V30T More than 60 cm More than 10 cm More than 30 cm More than 1 5 m More than 30 cm 13 ...

Страница 15: ...ortant The gap with the ground must be enlarged in areas subject to heavy snowfall Important A windbreaker may be necessary in open areas that are subjected to strong winds Exhaust pipe Fig 1 continued gaps heater exhaust pipe Not less than 45 cm Not less than 45 cm Strong wind Not less than 60 cm Not less than 60 cm Not less than 30 cm Not less than 20 cm 45 Flammable object Flammable object Non ...

Страница 16: ...ost or the heater has to be moved these are the dimensions and locations of the holes for the fuel pipe and exhaust pipe Do not remove any components from the heater Always contact your dealer if repairs are required If the electricity cable is damaged this may only be replaced with type H05 VV F and by a recognised installer Fig 3 Template The center of the flue pipe 266 cm Back of the heater 78 ...

Страница 17: ...of standard installation parts is supplied with your heater It may be necessary to order extra parts from your dealer if other installation methods are required L shaped hose 2 Pipe holder 1 Pipe stopper 1 Flue pipe 1 Bent joint 1 Wall bracket 2 set 3 ...

Страница 18: ...Hose band 2 Manual fuel pump 1 Fuel cap cover 1 Inlet hose 1 17 ...

Страница 19: ...ttle higher than the opening on the outside in order to create a slight gradient in the feed through and flue pipe after installation approximately 2 see Fig 6 This ensures that condensed water in the flue pipe flows to the outside and prevents the penetration of rainwater and snow after installation Comment The heater must be installed on a strong and stable floor The floor must be flat and level...

Страница 20: ...rt the inner flue pipe through the hole Make sure the arrow on the inner flue pipe is pointing up Secure the inner flue pipe to the wall with the three wood screws See Fig 7 Fig 7 Inner flue pipe Wood screws Arrow Inside Outside 130 230 mm 2 downward Min 19 ...

Страница 21: ...d Check that the caps are firmly in position See Fig 9 Use water or soap suds to provide lubrication when fitting the L shaped hose onto the inlet hose The total length of the exhaust pipe may be a maximum of 3 m max 3 bends From outside insert the outer flue pipe through the hole Secure the outer flue pipe to the wall by turning it clockwise This locks the two halves together See Fig 8 IMPORTANT ...

Страница 22: ...nlet hose to the inlet with the hose band Attach the bent joint to the flue pipe with the pipe holder If the extension pipe is used also attach the pipe holder to the connection of the bent joint and extension pipe Attach the bent joint to the outlet by sliding the pipe stopper into the outlet clip SeeFig 11 Fig 11 Fig 10 Pipe stopper Pipe stopper Outlet Inlet Bent joint Inlet hose 21 ...

Страница 23: ...eater to ensure that the airflow to the air circulation ventilator is notobstructed Inspect the interior of the building to ensure that the area immediately adjacent to the heater is free of fuel and objects that may obstruct the free flowof air Check that the room sensor is not exposed to draughts direct sunlight or heat radiated directly from the heater Use a spirit level to check that the heate...

Страница 24: ...TOYOTOMI CO LTD 5 17 Momozono cho Mizuho ku Nagoya Japan New 1 08 Printed in Japan 7157002060 ...