ENGLISH
,
1
IMPORTANT
1) READ AND UNDERSTAND INSTRUCTIONS BEFORE INSTALLING OR USING HEATER.
2) RETAIN INSTRUCTIONS IN A SAFE PLACE FOR FUTURE REFERENCE.
3) CHECK LOCAL AUTHORITY & BUILDING CODES FOR INSTALLATION REQUIREMENTS.
SECTION A:
SPECIFICATIONS
Model:
FF-55T/FF-55
Heater Efficiency:
92.4% (1)
Heat Rating:
High - 5.50 kW (18,800 BTU/h)
Med - 3.74 kW (12,800 BTU/h)
Low - 1.88 kW ( 6,430 BTU/h)
Fuel Consumption:
High - 0.622 L/h
Med - 0.423 L/h
Low - 0.213 L/h
Fuel System:
Removable fuel tank (7.6 L) / External tank (2)
Fuel Type:
Paraffin only
Dimensions (W × H × D):
496 × 600 × 339 mm
Weight:
20 kg/17 kg
Vent Pipe Hole:
70 ~ 80 mm diameter
Maximum Length of Vent Pipe System:
3 m, 3 bents or less (Section I “Installation”)
Electrical Rating:
230 Volts AC, 50 Hz
(220 Volts AC, 50/60 Hz) (3)
Preheat - 260W
Burning - 48W
(1) Heat and vaporized water are produced by fuel combustion. Heat rating does not account for heat loss due to
condensation of water vapor.
(2) External tank to be purchased separately. (Consult your supplier for options.)
(3) It is excluded from CE marking.
SAFETY FEATURES
Your heater is equipped with a number
of integral safety features. Please famil-
iarize yourself with these features. If the
heater shuts down due to the operation of
any safety device, ensure the problem is
identified and corrected. Note that normal
combustion flames inside the combustion
chamber, can be seen through a “peep
hole”, located in the front bottom left
hand corner of the hot air outlet louver’s.
1. Flame Sensor
Heater will automatically stop all operations if ignition fails or if flame fails during combustion, in order to prevent
fuel overflow. Error code will be displayed on the digital indicator.
2. Fuel Strainer
Special strainer catches any dirt or impurities present in the fuel before it is sent to the burner.
3. Overheat Protector
Automatically stops all operations if heater cabinet reaches abnormally high temperature due to motor malfunc-
tion or abnormal combustion, in order to prevent fire.
4. Power Failure Recovery System
If power fails during heater operation, heater will turn off. When power resumes, heater will automatically reignite
and maintain the normal selected temperature.
NOTE: The operation varies depending on the time length of power failure and other conditions.
Please see Section E “Operation” for more details.
5. Fully Vented System
Flue pipe system provides outside air for combustion and vents all combustion products to the outdoors.
Fuel pipe
Burner ring
Blower motor
Heat exchanger
Burner
Peep hole
Fuel
acceptance
fitting
Igniter
Fuel pump
Fuel sub tank
Removable
fuel tank
Heat shield plate
Overheat protector
Flame sensor
Fuel pipe
Burner ring
Blower motor
Fuel sump
Heat exchanger
Burner
Peep hole
Flame sensor
Igniter
Red reset button
Integral
fuel strainer
(inside)
Fuel pump
Heat shield plate
Overheat protector
FF-55T
FF-55