When you first use your new heater, ignite it out of the living area of your house, either in a garage or on area 

outside protected from strong drafts. Burn it for about 15 minutes to remove all of the protective oil present 
on the burner parts. If this 15 minutes “burn-in” is done inside, some objectionable odor will be observed. 
This procedure is necessary ONLY THE FIRST TIME your ignite your heater.

NOTE: 

If you have fueled your heater for the first time, or if you are refueling it after it has been out of fuel 

for a long time, you will need to wait about 30 minutes for the wick to become fully saturated.

1. Turn the wick adjuster knob clockwise until it stops.

It makes a spark discharge sound in the process of lighting procedure, but turn 
the wick adjuster knob clockwise until it stops.
As the wick rises within the heater, the wick adjuster knob turns with some 
resistance and makes a sound like the winding of a clock. Once the wick has 
reached its proper height, the automatic extinguisher is fully engages.
The wick adjuster knob can now move freely left or right to adjust the flame.

2. LIGHTING WITH A MATCH

You should not have to light the heater with a match, but should it become 
necessary, open the grille, lift the heat chamber up by holding the wire handle and 
touch the match to the top of the wick.
DO NOT allow burned parts of the match to fall or remain on the wick.

NOTE: 

To restore the automatic igniter system to proper operation, replace worn out 

batteries.

3. Be sure that heat chamber is properly seated by moving the wire handle left and 

right. If the movement is cough and jerky, it indicates that the heat chamber has 
not seated properly.

NOTE: 

An improperly seated heat chamber can cause high flame, smoke, and 
potential damage to the heater itself.
DO NOT leave the heater until you have determined that the flame is burning 
normally, which will be described in the following section.

6

DR-37_US.qxd  16.6.14 15:31   ページ 6

Содержание DR-37

Страница 1: ...o be used at altitudes up to 1 300m above sea level Consult with your dealer otherwise SAFETY TIPS FUEL GUIDE ASSEMBLY AND OPERATION CARE AND MAINTENANCE 1 3 4 9 REPLACEMENT OF PARTS STORAGE SPECIFICA...

Страница 2: ...ould be ignited by the heater resulting in fire and or explosion 5 NEVER fill heater fuel tank in living space Fill heater tank outdoors Never overfill your heater Always replace heater tank cap secur...

Страница 3: ...above 25 30 C lf the room temperature exceeds 25 30 C the flame may increase thereby producing smoke 8 Before going out or at bedtime turn the heater off making sure the wick is in its lowest positio...

Страница 4: ...avoid over filling heater How to Store lt ALWAYS ln a clean container clearly marked KEROSENE PARAFFIN ALWAYS AWAY FROM direct sunlight heat sources or extreme temperature changes NEVER ln a glass con...

Страница 5: ...ective packing out of the cabinet 2 REPLACE THE HEAT CHAMBER Remove the cardboard packing and replace the heat chamber assembly Point the wire handle to the front of the heater Close the grille 3 INST...

Страница 6: ...avoid overfilling the tank especially with very cold kerosene Overflow might occur due to expansion when the fuel warms up 5 Remove the siphon carefully allowing excess kerosene to drain from the tub...

Страница 7: ...with some resistance and makes a sound like the winding of a clock Once the wick has reached its proper height the automatic extinguisher is fully engages The wick adjuster knob can now move freely l...

Страница 8: ...ater be sure wick is high enough to keep the primary heat chamber heated to a uniform red glow from its top bottom 3 ADJUSTMENT OF MAXIMUM WICK HEIGHT After using the heater over a long period of time...

Страница 9: ...er knob counterclockwise until it stops This requires about a half turn At this point the flame is completely extinguished and the heater is off NOTE DO NOT use the automatic extinguisher to routinely...

Страница 10: ...from the living area of your house into a well ventilated area such as a garage or even a sheltered area outside If you burn the wick dry outside be sure that the heater is not exposed to strong draft...

Страница 11: ...e side and rear of the cabinet by using the screwdriver and lift the cabinet off bringing it slightly forward 5 Remove the hour 4 wing nuts around the wick holder 2 After the heat chamber has cooled c...

Страница 12: ...he sleeve 9 Squeeze the wick to loosen the three wick pins and remove the wick from the wick sleeve Ensure that you are wearing gloves and that you have a container in which to put the kerosene wick I...

Страница 13: ...nob to be sure the wick moves smoothly up and down After replacing the wick check the operation of the automatic extinguisher 15 Wick height on position 1 of wick life extender should be 8 mm 5 16 in...

Страница 14: ...hen the heater is refueled at a later date To do this disassemble the heater as described in items 1 throuth 4 under REPLACING THE WICK Remove the fuel acceptance fitting from the hole in the fuel sub...

Страница 15: ...r glass cylinder Lower glass cylinder REF 7 8 9 10 11 12 PART NAME Removable fuel tank Fuel filter cap Wick adjuster assembly Igniter unit Pendulum assembly Wick adjuster knob REF 13 14 15 16 17 PART...

Страница 16: ...TOYOTOMI CO LTD 5 17 Momozono cho Mizuho ku Nagoya Japan Printed in Japan 0272000903 New 07 16 DR 37_US qxd 16 6 14 15 31 15...

Отзывы: