5. REMOVE INVERTER COVER ASSEMBLY
RH
(1) Remove the 3 clips and the inverter cover
assembly RH from the inverter with converter
assembly.
6. CHECK TERMINAL VOLTAGE (w/ Quick
Charging Inlet)
Caution:
Wear insulated gloves.
(1) Open the charge lid.
(2) Open the cap of the DC charger inlet cable.
(3) Using a voltmeter, measure the voltage of the
high voltage inlet terminal.
Standard voltage:
0 V
Hint:
Use measuring range of DC 750 V or more on the
voltmeter.
7. DISCONNECT
DC CHARGER INLET
CABLE (w/ Quick Charging Inlet)
Caution:
Wear insulated gloves.
(1) Using a screwdriver, move the 2 lock levers as
shown in the illustration and disconnect the 2
DC charger inlet cable connectors from the EV
charger wire.
Lock Lever
8. DISCONNECT EV CHARGER WIRE (w/
Quick Charging Inlet)
Caution:
Wear insulated gloves.
(1) Disengage the 2 clamps and disconnect the EV
charger wires from the wiring harness clamp
bracket.