SAFETY TIPS FOR INSTALLATION
Follow the safety tips below when planning the installation of your Laser 300.
1. Intake and exhaust flue pipe openings must be fully exposed to outside air. Do not
vent into chimney, garage, basement under the floor, or into any enclosed area.
2. Do not install flue pipe in close proximity to other objects or materials (See page
26).
3. Before making a hole in your wall for the flue pipe, make sure the area is free of
electrical wires, gas pipes and other obstacles.
4. Do not install flue pipe where it will be exposed to heavy snow collected leaves or
strong drafts.
5.
Do not install the flue pipe
down from the heater.
6. Total length of extension pipe between heater and flue pipe must be no greater
than 10 ft. and no more than 3 bends.
NOTE: When using extension pipes always cover the exhaust pipe with the
insulating cloth cover.
7.
B-Vent shall not be used in the vent system.
For all prescribed heater installations, the flue pipe must always be installed in a
horizontal position.
SAFETY TIPS FOR INSTALLATION
Long
extension
kit
Snow
Snow
Must be
higher
24"(Min.)
Wind
break
Strong
wind
Important:
In areas of hea-
vy snow falls,
ground surface
clearance must
be increased
according to
average snow
falls.
Important:
In open area
with strong
wind, a wind
break may be
necessary.
Gasoline
Kero- sene
Gas pipe
25