TOYO PUMPS EUROPE
Edition 03.11.2009
- 5 -
TROUBLESHOOTING LIST
The pump is in duty but doesn’t turn even as the switch is in “ON” position.
•
The pump emits no sound :
-
Electric alimentation problem:
à
Verify if the network is under tension and/or the generator works properly.
-
Defective connection or breakdown of one of the alimentation wires:
à
Verify all connections and check the state of the wires.
-
Alimentation throw one single phase :
à
Verify the connections and fuses.
•
The pump emits a sound :
-
A foreign body blocs the agitator or is jammed between impeller and impeller disc :
à
Remove the foreign body.
-
The impeller disc is blocked against the impeller :
à
Adjust the space between the two parts as indicated in the technical
characteristics.
-
A bearing is broken :
à
Replace the bearing.
-
Wire breakdown in one of the wires inside the winding of the stator :
à
Consult your supplier.
-
The stator is burned :
à
Consult your supplier.
The pump turns when the switch is in “ON” position but …
•
The pump emits an abnormal sound :
-
A foreign body blocs the agitator or is jammed between impeller and impeller disc :
à
Remove the foreign body.
-
The impeller disc is in contact with the impeller :
à
Adjust the space between the two parts as indicated in the technical
characteristics.
-
Defective bearing :
à
Replace the bearing.