20'
10'
8'
6
40'
MAX.
4'
2'
48'
4' MAX.
'
18” MIN BEFORE ELBOW
MINIMUM VENT HEIGHT
Various combinations of vent runs may be
used. Refer to Fig. #31
for details. For optimum
performance and flame appearance, keep the
vent length to a minimum and limit the number
of elbows. Connections between each vent
system component must be tightly joined,
secured with sheet metal screws and sealed.
CAUTION:
Under no condition
should combustible
material be closer than
1 3/4 inches from any
part of the vent pipe.
Only 45º elbows can be
used in this vent system.
Maximum number of
elbows is 2.
Fig. #31
19
TCWS.54CE3 270313-44
Roof Termination Venting Chart
Содержание TCWS.54CE3
Страница 40: ...40 TCWS 54CE3 2 0313 44 ...
Страница 41: ...41 TCWS 54CE3 270313 44 ...
Страница 42: ...42 TCWS 54CE3 2 0313 44 ...