Fig. #15
8
10
10
9
SIDE FACING
CLEARANCES
ROCK FACE
AREA
MINIMUM
6”
53 5/8”
This fireplace may be recessed up to a
maximum depth of 6”, this recess must
be constructed from non combustible
material. The space between the
outside lintels and the firebox must be
completely free of any obstructions or
debris and the window with trim fitted
must be able to move freely. No build-
ing material is permitted to protrude
past the lintel bars attached to the fire-
place under ANY circumstance.
Fig. #15b
2. Attach the Assembled Frame to the
Unit
•
Attach the framing kit to the unit.
(Fig. #13).
• Align the assembled frame to the unit
framing brackets. (Fig #14) Attach at
the fastening points through the
access holes in the outer side studs
(3).
3. Secure to Existing Framing
•
Bend out the tabs 90 degrees before
inserting the unit into its framed housing
(Fig. #14).
•
Secure the frame assembly to the wood
frame through the tabs.
4. Install Non-Combustible Board Top
and Sides
•
Use drywall screws to install the
non-combustible board top ,
bottom ,sides top center and
bottom center . (Fig. #15)
Fig. #13