
190907-12
TCVT.WSPVB
7
The gas control system is located on the right hand side of
the fi rebox behind an access panel and the decorative brick
panel.
1) Remove burner grate, logs and brick panels if already
installed.
2) Remove access panel from right hand side of the fi rebox.
(Fig. #10)
3) Locate and disconnect the spade connectors in the black
wire loop on the right side of the module and in the orange wire
running from the module to the socket on the valve labelled
“pilot”. (Fig. #11 and 12)
4) Using the wires provided, connect the 120V “hot” supply
wire to one of the black wires from the control module. Then
connect the “hot” wire from the power vent blower to the other
black wire on the control module. (Fig. #13)
ACCESS PANEL
Fig. #10
SPADE CONNECTORS IN BLACK
WIRE LOOP
Fig. #13
Fig. #11
SUPPLIED WIRES TO
CONNECT TO BLACK
WIRE ON MODULE
HOT WIRE
FROM BLOWER
HOT WIRE FROM
120V SUPPLY
ORANGE WIRE
FROM MODULE
TO VALVE
Fig. #12
Control System Connections