Town & Country Fireplaces TCVT.WSPVB Скачать руководство пользователя страница 1

OPTIONAL
VERTICAL OR 
HORIZONTAL
POWER VENT KIT

TCVT.WSPVB
INSTALLATION AND
OPERATING
INSTRUCTIONS

190907-12 

 

                        

 

 

TCVT.WSPVB 

 

 

 

 

 

5056.425211

5 x 8 Pipe
(Simpson Duravent)
(Secure Vent)
(Selkirk Direct-temp)

IMPORTANT:
THESE INSTRUCTIONS ARE TO REMAIN
WITH THE APPLIANCE INSTRUCTIONS

These instructions are supplementary to the Installation and 

Operating Instructions supplied with the fi replace and should 

be kept together. Refer to the Installation and Operating 

Instructions for proper gas supply, safety requirements and 

operating instructions

Power Vent Terminal 
(TCVT.502461)

Vent Adaptor 
(5096.814)

Содержание TCVT.WSPVB

Страница 1: ... IMPORTANT THESE INSTRUCTIONS ARE TO REMAIN WITH THE APPLIANCE INSTRUCTIONS These instructions are supplementary to the Installation and Operating Instructions supplied with the fireplace and should be kept together Refer to the Installation and Operating Instructions for proper gas supply safety requirements and operating instructions Power Vent Terminal TCVT 502461 Vent Adaptor 5096 814 ...

Страница 2: ...in the absence of local codes with the Natural Fuel Gas Code ANSI Z223 1 NFPA 54 or the Natural Gas and Propane Installation Code CSA B149 1 This appliance must be electrically grounded in accordance with local codes or in the absence of local codes with the National Electrical Code ANSI NFPA 70 or the Canadian Electrical code CSA C22 1 MINIMUM CLEARANCES TO COMBUSTIBLE Vertical vent pipe 1 5 in 3...

Страница 3: ...regula tor I clearance to service regulator vent outlet 6 feet 1 8 m minimum J clearance to nonmechanical air supply inlet to building or the combustion air inlet to any other appliance 12 inches 30 cm minimum K clearance to a mechanical air supply inlet 6 feet 1 8 m minimum L clearance above paved side walk or a paved driveway located on public property 7 feet 2 1 m minimum M clearance under vera...

Страница 4: ...ng 5 Attach the vent adaptor directly to the appliance with three screws and seal outer pipe with aluminium tape provided Note The inner pipe does not need to be sealed Fig 4 6 Connect the high temperature silicone tube to the vacuum pressure taps on the adaptor secure with the hose clamp provided and route the tube through any hole back to control box Fig 4 Tube may touch unit and be trimmed if r...

Страница 5: ...foil tape 7 Remove the junction box cover Part D 8 Remove and discard the exhaust shield Part E 9 Apply a bead of silicone on the bottom flange of the power vent terminal TCVT WSPVB 10 Slide the vent through the drip shield and at the same time thread the electrical lead through the hole in the bottom of the terminal 11 With the power vent terminal resting on the drip shield align the eight holes ...

Страница 6: ...T 8074 Part C Drip Shield Part B Vertical Standoff Part A Flashing Site Fabricated Chase MUST ALIGN 8 x 1 2 S S 16 Required 8 x 1 1 2 S S 8 REQUIRED NOTE Holes to secure rain cap are not predrilled SILICONE ALL CONNECTING FACES 14 2 Wire w Ground Final Installation Height 21 6 TCVT WSPVB 190907 12 Fig 5 Vertical Through Roof Venting ...

Страница 7: ...of the module and in the orange wire running from the module to the socket on the valve labelled pilot Fig 11 and 12 4 Using the wires provided connect the 120V hot supply wire to one of the black wires from the control module Then connect the hot wire from the power vent blower to the other black wire on the control module Fig 13 ACCESS PANEL Fig 10 SPADE CONNECTORS IN BLACK WIRE LOOP Fig 13 Fig ...

Страница 8: ...alve The use of a sheet metal screw will damage the valve 7 Attach the silicone tube from the upper pressure tapping to the low side of the pressure switch and secure using the hose clamp provided Fig 15 8 Attach the silicone tube from the lower pressure tapping to the high side of the pressure switch and secure using the hose clamp provided Fig 16 9 Continuewithinstallationandreassemble all of th...

Страница 9: ... 1 4 Female Connector 1 4 Female Connector Optional Power Vent Kit provided by Town Country Communication Wires 1 4 Female Connector 1 4 Male Connector 120 Volt Common wire White 120 Volt Hot wire Black Low volt relay Inside the module 1 4 Female Connector 1 4 Male Connector Pull connectors apart to connect to optional power vent 190907 12 TCVT WSPVB 9 Wiring Diagram 115V 60 Hz 1 8A ...

Страница 10: ...AK 4 28 DRIP SHIELD 1 10 SCREW 8 32 x1 1 4 RND HD 4 29 9072 7 PRESSURE SWITCH CLIP 1 11 8 32 x5 16 PAN QUADREX 1 30 VENT COLLAR 1 12 HEX NUT STAINLESS 18 8 PLAIN 4 31 VENT EXHAUST ASSEMBLY 1 13 1 4 20 x1 2 NC GR 5 HEX C S PLTD 5 32 VERTICAL RAIN CAP TCVT 1 14 5096 814 VENTING ADAPTER 1 33 VERTICAL STANDOFF 1 15 1 4 LDF PAPER 1 34 TCVT 5062512 BLOWER WIRING 1 16 35 TCVT 506271C PRESSURE SWITCH WIRI...

Страница 11: ...1202 48 Pipe Length 1211 11 to 14 5 8 Pipe Adjustable 1217 4 10 Pipe Adjustable 1245 45 Elbow 1290 90 Elbow 1240 Round Ceiling Support Wall Thimble Cover 1241 Cathedral Ceiling Support Box 1242 Wall Firestop 1247 Wall Thimble 1263 Ceiling Firestop 1288 Wall Strap SECURE VENT COMPONENTS Number Description SV5L6 6 Pipe Length SV5L12 12 Pipe Length SV5L24 24 Pipe Length SV5L36 36 Pipe Length SV5L48 4...

Страница 12: ...TECHNICAL SUPPORT 1 877 715 2664 www townandcountryfireplaces net 2975 Allenby Rd Duncan BC V9L 6V8 Printed in Canada ...

Отзывы: