Before adding the ember material please ensure that the ceramic fi bre fi ller pieces are cor-
rectly located in the bunrer as per fi gure #12.

Two bags of ember material is shipped with the fi replace and need to be installed to ensure 
optimum performance and fl ame appearance.

Pull apart the material into ember size pieces (approximately 1” squares) and gently place 
them into the lower burner pan. Do not compress, leave it loose for best performance. Fill 
the lower burner pan level with the top of the pan at rear, and gradually slope forward to the 
fi rebox fl oor, covering both lower burner tubes. Place remaining ember material outside of 
the burner pan as desired to cover-up gas lines and brackets.

Note:  Ember material placement and amount will affect fl ame appearance. More ember 
material results in lower fl ame height. Add or remove as needed until desired fl ame affect. 

Ember Material Placement

GLOWING EMBERS

LOG GRATE

Fig. #13

Fig. #12

CERAMIC FIBRE
FILLER PIECES

6

Ember Material

Содержание TC54.LP02.C

Страница 1: ...with the fireplace and should be kept together Refer to the Installation and Operating Instructions for proper gas supply safety requirements and operating instructions TC54 COUNTRY HOME BURNER KIT TC54 LP02 C PROPANE ONLY PART TC54 LP02 C INSTALLER LEAVE THIS MANUAL WITH APPLIANCE CONSUMER RETAIN THIS MANUAL FOR FUTURE REFERENCE ...

Страница 2: ...t assembly LOG PACK EMBER MATERIAL two bags HARDWARE PACKAGE 1 Attach the lower burner assembly to the floor of the firebox with two screws Fig 1 2 Attach the manifold supply tube from the lower burner to the front bulk head fitting and tighten Fig 2 Ensure that there are no leaks Fig 1 Fig 2 2 Package Contents Burner Grate Installation ...

Страница 3: ... sensor leads from lower burner pilot to the front electrical bulk head Fig 4 The spark electrode connection has a red dot above it 5 Positionthegrateandattachittothefloorwithtwoscrewslocated behind the front legs Fig 5 6 Attach the manifold supply tube from the upper burner to the rear bulk head fitting and tighten Fig 6 Ensure that there are no leaks ORANGE WIRE Fig 3 Fig 4 Fig 5 Fig 6 3 ...

Страница 4: ...n Fig 7 Ensure there are no leaks 9 Attach spark electrode ORANGE and sensor leads from upper burner pilot to the rear electrical bulk head Fig 8 The spark electrode connection has a red dot above it A panel set must now be installed See Installation and Operating Instructions manual for details ORANGE WIRE Fig 7 Fig 8 4 ...

Страница 5: ... Pressure Propane Minimum 12 5 wc Maximum 13 9 wc Manifold Pressure Maximum 11 0 wc Minimum 5 5 wc Note To test the gas pressure turn off the gas supply before removing the plug from the supply pressure test port or manifold pressure test port There are four ports on this fireplace the top two are connected to the rear burner and the bottom two are to the front burner Manifold pressures should be ...

Страница 6: ...lower burner pan Do not compress leave it loose for best performance Fill the lower burner pan level with the top of the pan at rear and gradually slope forward to the firebox floor covering both lower burner tubes Place remaining ember material outside of the burner pan as desired to cover up gas lines and brackets Note Ember material placement and amount will affect flame appearance More ember m...

Страница 7: ...as indicated by the following pictures The three main logs have holes and or pins Engage each pin in the corresponding holes The four smaller logs do not have holes or pins They rest in position Locate as per the diagrams Fig 14 20 Note Improper placement of logs will cause sooting on internal parts and glass The logs may need to be repositioned slightly to avoid excessive flame impingement Fig 14...

Страница 8: ...061107 12 TC54 LP02 C 2 2 3 1 6 4 5 7 Fig 18 Fig 19 Fig 20 8 ...

Страница 9: ... area may be hot Turn off the fireplace and allow the unit to cool before proceeding To Adjust See Fig 22 1 Open and remove window frame and set aside See Window Frame Removal section found in the Installation and Operating Instructions manual 2 Remove the logs and set aside 3 Loosen the screw in the Primary Air Shutter 4 Rotate the shutter to increase or decrease the amount of primary air PRIMARY...

Страница 10: ...021 01 9 FLEX 1 2 LINE DORMONT 5019 223 10 FLEX 1 4 LINE DORMONT 16 5019 225 11 PILOT ASSEMBLY 5005 025 12 FLEX 1 4 LINE DORMONT 24 5019 227 LOG SET COMPLETE 5098 74615 REAR 1 shown in fig 20 5098 74615 1 RIGHT 2 shown in fig 20 5098 74615 2 LEFT 3 shown in fig 20 5098 74615 3 BOTTOM RIGHT 4 shown in fig 20 5098 74615 4 BOTTOM CENTRE 5 shown in fig 20 5098 74615 5 BOTTOM LEFT 6 shown in fig 20 509...

Страница 11: ...061107 12 TC54 LP02 C 11 Notes ...

Страница 12: ...TECHNICAL SUPPORT 1 877 715 2664 www townandcountryfireplaces net 2975 Allenby Rd Duncan BC V9L 6V8 Printed in Canada ...

Отзывы: