TC36.NGST07C 010611-20
17
Minimum
rate screw
13. Remove access panel, 10 screws, and set aside (Fig. #41)
14. Remove the minimum rate screw located in the valve. (Fig. #36).
Removing the Minimum Rate Screw
The minimum rate screw is sealed with an o-ring near the bottom of the screw.
Use a thin bladed screwdriver to back the screw out to the limit of the threading.
At this point, a groove on the screw body will be visible just above the valve body.
Insert a thin tool (knife blade or fi ne screwdriver blade) into the groove and gently
pry the screw up. It helps to rotate the screw while lifting on it. (Needle-nose pliers
are a help.).
15. Replace the minimum rate screw with the one provided in the propane conver-
sion kit supplied with this fi replace. Ensure that the screw is fully installed
(Fig. #37).
16. Unscrew the aluminum cap from the top of the pressure regulator (Fig. #38).
17. Press down on the center post and rotate 90°. The center post should stay
down (Fig. #39). Replace the aluminum cap.
NG
LP
Minimum
rate screw
Fig. # 36
Fig. # 37
Fig. #38
Fig. #39