COMMISSIONING AND HANDOVER INSTRUCTIONS 

 

Ensure all parts are fitted in accordance with the instructions. 
On completion of the installation allow a suitable period of time for any fire cement and 
mortar to dry out, before lighting the stove. 
Once the stove is under fire check all seals for soundness and check that the flue is 
functioning correctly and that all products of combustion are vented safely to atmosphere 
via the chimney terminal. 
On completion of the installation and commissioning ensure that the operating instructions 
for the stove are left with the customer. 
Ensure to advise the customer on the correct use of the appliance and operating tools and 
warn them to use only the recommended fuel for the stoves. 
Advise the user what to do should smoke of fumes be emitted from the stove. 
The customer should be warned to use a fireguard to BS8423:2002 in the presence of 
children, elderly and / or infirm persons

 

SPARES

 

– 

The approved dealer whom you purchased your stove from will able to supply 

you with spares you may require in the future. The majority of the parts for the Saltburn 
Smoke Control and the Dalby Smoke Control are the same with the exception of the Fuel 
Guard, Door Rope kit, Glass seal and Door Glass - in this instance please advise the dealer 
when ordering if your stove is the Saltburn Smoke Control – ( flat door version ) or Dalby 
Smoke Control – ( curved door version). 

 

Product Fiche 

Commission Delegated Regulation (EU) 2015/1187 

Energy Labelling of Local Space Heaters

 

Supplier`s Name or Trademark: 

  

 

 

Town & Country Fires 

 

  

  

 

 

 

 

 

  

 

  

Suppliers Model Identifier: 

 

 

 

 Saltburn SC / Dalby SC 

 

  

  

 

 

 

 

 

  

 

  

Energy Efficiency Class of Model: 

 

 

A+ 

 

  

  

 

 

 

 

 

  

 

  

Nominal Heat Output to Room (kW): 

 

 

 

5.0 

 

  

  

 

 

 

 

 

  

 

  

Nominal Heat Output to Water (kW): 

 

 

 

n/a 

 

  

  

 

 

 

 

 

  

 

  

Net Efficiency (%): 

85.2 

 

  

  

 

 

 

 

 

  

 

  

 

Energy Efficiency Index (%):  

114 

 

  

 

        

 

  

  

 

 
 
 

Содержание DALBY SMOKE CONTROL

Страница 1: ...th and Safety at Work Act 1974 to British Standard BS 8303 and to all local Building Regulations including those referring to National and European standards These need to be complied with when installing the appliance Ensure that the flue pipe diameter is not less than the 125mm diameter outlet on the appliance There must not be an extractor fan fitted in the same room as the Saltburn Dalby Smoke...

Страница 2: ...ed from the controls which generally apply in the smoke control area The Secretary of State for Environment Food and Rural Affairs has powers under the Act to authorize smokeless fuels or exempt appliances for use in smoke control areas in England In Scotland and Wales this power rests with the Ministers in the devolved administrations for those countries Separate legislation the Clean Air Norther...

Страница 3: ...commended that this appliance is installed on a solid level non combustible hearth conforming to current Building Regulations This appliance has been tested for hearth temperatures and the maximum temperature was 59 degrees C so is also suitable for a 12mm hearth INSTALLATION A minimum flue draught of 24 Pa is required for nominal heat output As referred to in document J of the Building regulation...

Страница 4: ...ue pipe can be placed into the spigot on top of the stove and round the outside of the collar on the register plate so forming a funnel effect In this way any moisture running down the chimney will be directed back into the stove instead of seeping out onto the top of the stove Connect the stove to the chimney using vitreous enameled flue pipe from the top of the stove Make sure that all joints an...

Страница 5: ... small piece of fire lighter about 25mm square is big enough and then add small sticks taking care not to smother the flames When the sticks are well alight add small logs gradually increasing the size Once the fire is well established and hot the bottom air slide can be closed A stove handle cover is included with the stove place the black cover over the handle when opening and closing the door t...

Страница 6: ...put setting Before opening the door to re fuel open the primary air at the bottom right hand side Add the fuel and then close the door Then open the left hand lever leaving the right hand lever open for 2 to 3 minutes Then close the right hand lever and use the left hand lever to adjust to suit required heat Refueling on to a low fire bed If there is insufficient burning material in the firebed to...

Страница 7: ...move the baffle once a year to clean any debris that may have collected there The chimney flue should be swept and checked every year The glass on the stove door can be cleaned better when the glass is cool using a damp cloth or sponge pan scrubber for any stubborn marks Stove glass cleaner may be used if required The body of the stove can be brushed with a soft brush do not use water on the paint...

Страница 8: ... supplier 4 Smoke is being emitted from the chimney Check that the fuel being used is as described and that the operation of this manual is being followed If smoke is being emitted whilst refueling onto a low firebed then kindling should be used WARNING NOTE Properly installed operated and maintained this stove will not emit fumes into the dwelling Occasional fumes from de ashing and re fuelling m...

Страница 9: ... to do should smoke of fumes be emitted from the stove The customer should be warned to use a fireguard to BS8423 2002 in the presence of children elderly and or infirm persons SPARES The approved dealer whom you purchased your stove from will able to supply you with spares you may require in the future The majority of the parts for the Saltburn Smoke Control and the Dalby Smoke Control are the sa...

Страница 10: ...stoves should be as per our Installation User Instructions provided with the stove Any warranty claim requires Proof of defective workmanship and delivery of the defective product to our factory within twelve months of the date of purchase Parts which are classed as consumables and are excluded from our Guarantee include Grates Fire Bricks Baffles Fuel Guards Ash Pan Glass Door Glass Seals and Pai...

Отзывы: