Bottom of fireplace
Maximum
height of 1”
above bottom
of fireplace
Lintel
Hearth
Extention
Figure 20: TC42D Hearth extension.
This fireplace is designed to finish
either flush with the facing material
or can be installed with a 4 1/2 inch
recess, see “Figure 10: TC 42D Non
combustible board dimensions.” on
page 9.
The fireplace can accommodate
facing material thickness from 1/2
of an inch to 2 1/4 inches if installing
flush.
Care should be taken to correctly
determine the facing material
thickness so that the fireplace is
positioned so that the front of the
fireplace is flush with the facing
material.
Facing material must not interfere
with the ability for the door or the
screen to open.
Caution: While a hearth extension is not required and combustible flooring materials may be brought
directly up to the fireplace, many materials (such as wood flooring) may not tolerate the radiant heat from
this fireplace, resulting in discoloration, shrinking and cracking. For this reason, we suggest a non-com-
bustible hearth that is no more than 1” above the bottom of the fireplace. If thicker, fireplace must be raised
accordingly.
Caution: Hearth extensions thicker than 1” will interfere with the safety screen and window frame when
opening.
Fireplace Facing Allowance
Figure 19: Framing edge location.
NON-COMBUSTIBLE
FINISH MATERIAL
NON-COMBUSTIBLE
BUILDING MATERIAL MAY NOT
EXTEND PAST THIS POINT
SCREEN
DOOR
13
100000364-50
TC42D2 091418-44
Hearth Extension