-9-
A35 IRQSUB1
IRQ 1
I
B35 NC Reserved
A36 IRQ5
IRQ 5
I
B36 CS2 Reserved
O
A37 IRQ6
IRQ 6
I
B37 DREQ0
DMA (Do not use)
I
A38 IRQ7
IRQ 7
I
B38 DREQ1
DMA (Do not use)
I
A39 HRES
Reset output
I
B39 DRAK1
DMA (Do not use)
O
A40 NC
B40 DRAK0
DMA (Do not use)
O
A41 NC
B41 NC
A42 RD
Read
O
B42 NC
A43 IOSELSEL
SUB board selection
O
B43 ANAD0
Analog input 0
I
A44 NC
B44 ANAD1
Analog input 0
I
A45 DACK0
DMA (Do not use)
O
B45 INI_RD Reserved
I
A46 DACK1
DMA (Do not use)
O
B46 INI_G Reserved
I
A47 RESET
Reset input
I
B47 INI_CE Reserved
I
A48 WAIT
Wait
B48 INI_WR Reserved
I
A49 GND
Signal
GND
B49 GND Signal
GND
A50 GND
Signal
GND
B50 GND Signal
GND
PN3 Terminals used by manufacturer (Do not use)
#
Signal
Function
#
Signal
Function
1 TCK
Clock
I
2 GND
Signal
GND
3 TDO
Data
output
O 4 VCC_3.3 VCC
3.3V
5 TMS
Mode
select
I
6 VCC_3.3 VCC
3.3V
7 NC
Not
connected
8 NC
Not
connected
9 TDI
Data
input
I 10 HRES Reset
request
I
PN4 Power terminal
#
Signal
Function
1 VCC_5
5v
power
source
2 GND
Signal
GND
3 GND
Signal
GND
4 24V
24v power source
(Not connected OK)
PN5 Drawer output
#
Signal
Function
1 24
v
Power source output
O
2 OCGND
Open collector GND output
O
Содержание TMM1000
Страница 1: ...TMM1000 HARDWARE MANUAL 2003 07 04...