8-2. Deflection Processor (IC301)
8-2.1. Horizontal section
1) Horizontal oscillation
R314 and C347 set horizontal free frequency.
Auto-sync processing can be done from 30KHz to 70KHz by means
of IC301 without any adjustment.
2) Phase shift
Horizontal phase shift is controlled by IC601 using I
2
C BUS control.
3) Horizontal driver output
The output pulse, which has the duty-cycle of 47%, is available at pin
26 of IC301.
This output is used for horizontal drive circuit.
4) B+ control driver output
The output pulse is available at pin 28 of IC301 and it is used for
H-scan voltage control driver.
5) X-ray protection
When the fly-back voltage rises up to an unacceptable level, x-ray
protection is activated. X-ray input pin 36 of ic601 is above 3.2v
This result is that complete line drive stage stops working.
The reset of this protection is obtained by Main power off.
8-2.2. Vertical section
1) Vertical oscillation
The free running frequency of the vertical oscillator is determined by
the capacitor C342 at pin VCAP (pin22) of IC301.
2) Vertical amplitude
Vertical amplitude is controlled by IC601 using I
2
C.
3) Vertical position
Vertical position is controlled by IC601 using I
2
C.