tousek
/ E_GSM-400_00 / 07. 05. 2018
- 7 -
SMS commands / Befehlsgebung
command
entry
8
Save telephone numbers for GATE OPEN-command:
to save telephone numbers that should enable an opening command
on output through a call
(max. 300)
.
pass
:
password (max. 5 digits)
telnr
: telephone number (max. 10 per command separated by comma)
IMPORTANT: the country code (e.g. +43) , depending on automatic
exchange in country, may be necessary!
It is necessary to send your mobile phone number!
pass,
MAC,telnr,telnr,...
e.g. 12345,MAC,+436641234567,
+436767654321
if a tel. number is followed by a
„U“, an by a digit yyy
, it means that,
this number executes a defined amount of operations (in this exapmle: 5),
and that the number gets then deleted.
pass,
MAC,telnrUyyy
e.g. 12345,MAC,+436767654321U5
9
delete telephone numbers for GATE OPEN-command:
to delete telephone numbers, that were enabled to generate an ope-
ning command through a call.
pass
:
password (max. 5 digits)
telnr
: telephone number (max. 10 per command separated by comma)
pass,
DAC,telnr,telnr,...
e.g. 12345,MAC,+436641234567,
+436767654321
To delete a phone number using „DAC“, it is necessary to dial it with the same dial code/ prefix
that was used to store it with the command „MAC“!
10
delete all telephone numbers for GATE OPEN-command:
pass
:
password (max. 5 digits)
pass,
DAC,
pass,pass
e.g. 12345,DAC,12345,12345
Saving / deleting telephone numbers is also possible by means of a call
(see point 3a)
SMS Commands / In-, outputs
command
entry
11
activation of outputs OUT 1:
pass
:
password (max. 5 digits)
z
: number of concerning output
(=1)
telephone call
pass,
OUT,ON,z
e.g. 12345,OUT,ON,1
12
deactivation of outputs OUT 1 [ = ] :
pass
:
password (max. 5 digits)
z
: number of concerning output
(=1)
telephone call
Note: in the „monostable“ operating mode, this command has no effect since
the shutdown is performed automatically (after 0.5s).
pass,
OUT,OFF,z
e.g. 12345,OUT,OFF,1
13
request status of output OUT 1:
pass
:
password (max. 5 digits)
answer SMS: „out 1 on (off) + call
pass,
OUT?
14
output relay OUT 1 set to MONOSTABIL [ = ]:
sets the switching behaviour of the output relay to monostable (active for 0,5s).
pass
:
password (max. 5 digits).
z
: number of concerning output
(=1)
pass,
OUTRE,z,M
e.g. 12345,OUTRE,1,M
output relay OUT 1 set to BI-STABLE:
sets the switching behaviour of an output relay to bistable (ON, OFF).
pass
:
password (max. 5 digits)
z
: number of concerning output
(=1)
pass,
OUTRE,z,B
e.g. 12345,OUTRE,1,B
output relay OUT 1 with TIMER:
sets a timer function for an output relay.
pass
:
password (max. 5 digits)
z
: number of concerning output
(=1)
yyyy
: time in seconds (1–9999s)
pass,
OUTRE,z,Tyyyy
e.g. 12345,OUTRE,1,T60