Dimming Mode

Each allows for different amounts of steps for much smoother (and slower) dimming capabilities. 

1.) Navigate the menu using the 

<UP/DOWN>

 buttons until you reach 

nodE

.

2.) Push the 

<ENTER>

 button.

3.) Use the 

<UP/DOWN>

 buttons to select 

nod0-nod4

.

4.) Press the 

<ENTER>

 button to confirm.

DMX Values In-Depth (11-Channel Mode)

Channel

Value

What It Does

1

000 <--> 255

Dimmer (0% <--> 100%)

2

000 <--> 255

Red Intensity (0% <--> 100%)

3

000 <--> 255

Green Intensity (0% <--> 100%)

4

000 <--> 255

Blue Intensity (0% <--> 100%)

5

000 <--> 255

Amber Intensity (0% <--> 100%)

6

000 <--> 255

White Intensity (0% <--> 100%)

7

000 <--> 255

UV Intensity (0% <--> 100%)

8

 

000 <--> 010

011 <--> 255

Strobe

No Function

Strobe (Slow <--> Fast)

9

000 <--> 015

016 <--> 018

019 <--> 021

022 <--> 024

025 <--> 027

028 <--> 030

031 <--> 033

034 <--> 036

037 <--> 039

040 <--> 042

043 <--> 045

046 <--> 048

049 <--> 051

052 <--> 054

055 <--> 057

058 <--> 060

061 <--> 063

064 <--> 066

067 <--> 069

070 <--> 072

073 <--> 075

076 <--> 078

079 <--> 081

082 <--> 084

085 <--> 087

088 <--> 090

091 <--> 093

094 <--> 096

097 <--> 099

100 <--> 102

103 <--> 105

106 <--> 108

109 <--> 111

Static Auto Mode

Dimming

Red

Green

Blue

Amber

White

UV

R+G

R+B

R+A

R+W

R+UV

G+B

G+A

G+W

G+UV

B+A

B+W

B+UV

A+W

A+UV

W+UV

R+G+B

R+G+A

R+G+W

R+G+UV

R+B+A

R+B+W

R+B+UV

R+A+W

R+A+UV

R+W +UV

G+B+A

112 <--> 114

115 <--> 117

118 <--> 120

121 <--> 123

124 <--> 126

127 <--> 129

130 <--> 132

133 <--> 135

136 <--> 138

139 <--> 141

142 <--> 144

145 <--> 147

148 <--> 150

151 <--> 153

154 <--> 156

157 <--> 159

160 <--> 162

163 <--> 165

166 <--> 168

169 <--> 171

172 <--> 174

175 <--> 177

178 <--> 180

181 <--> 183

184 <--> 186

187 <--> 189

190 <--> 192

193 <--> 195

196 <--> 198

199 <--> 201

202 <--> 204

205 <--> 255

G+B+W

G+B+UV

G+A+W

G+A+UV

G+W+UV

B+A+W

B+A+UV

B+W+UV

A+W+UV

R+G+B+A

R+G+B+W

R+G+B+UV

R+G+A+W

R+G+A+UV

R+G+W+UV

R+B+A+W

R+B+A+UV

R+B+W+UV

R+A+W+UV

G+B+A+W

G+B+A+UV

G+B+W+UV

G+A+W+UV

B+A+W+UV

R+G+B+A+W

R+G+B+A+UV

R+G+B+W+UV

R+G+A+W+UV

R+B+A+W+UV

G+B+A+W+UV

R+G+B+A+W+UV

Auto Run (Slow <--> Fast)

10

000 <--> 015

016 <--> 255

Auto Mode

No Function

Color Jump (Slow <--> Fast)

11

000 <--> 005

006 <--> 055

056 <--> 105

106 <--> 155

156 <--> 205

206 <--> 255

32-Bit Dimmer

As set in the control menu display

Mode 0 = 8-bit, 256 dimming steps

Mode 1 = 32-bit, 0-25% intensity range

Mode 2 = 32-bit, 0-50% intensity range

Mode 3 = 32-bit, 0-75% intensity range

Mode 4 = 32-bit, full intensity dimming

Содержание ip EXA

Страница 1: ...Blizzard Lighting LLC www blizzardlighting com Waukesha WI USA Copyright c 2014 ip EXA tm SUITABLE FOR OUTDOOR USE...

Страница 2: ...s 8 3 Pin 5 Pin Huh 8 Take It To The Next Level Setting up DMX Control 8 Fixture Linking Master Slave Mode 9 Mounting Rigging 9 4 Operating Adjustments 10 Navigating The Control Panel 10 Control Panel...

Страница 3: ...tly off a switched circuit and cannot be run off a rheostat variable resistor or dimmer circuit even if the rheostat or dimmer channel is used solely for a 0 to 100 switch AC Voltage Switch Not all fi...

Страница 4: ...pe ALWAYS secure fixture using a safety chain NEVER carry the fixture by its cord Use its carrying handles DO NOT operate at ambient temperatures higher than 104 F 40 C In the event of a serious opera...

Страница 5: ...nvection cooled cast aluminum housing Dual mounting brackets for positioning flexibility Flicker free constant current 500MA LED driver IP rated locking power and 3 pin DMX connections DMX Quick Refer...

Страница 6: ...nado IP EXA Pin Up Picture High Power 6 in 1 RGBAW UV LEDs Heavy Duty Cast Aluminum Enclosure Dual Adjustable Mounting Brackets Figure 2 The Rear Connections AC Power Out DMX In DMX Out Touch Sensitiv...

Страница 7: ...support Fixtures on a serial data link must be daisy chained in one single line Also connecting more than 32 fixtures on one serial data link without the use of a DMX optically isolated splitter may r...

Страница 8: ...you d like to build your own the chart below details a proper cable conversion Conductor 3 Pin Female Output 5 Pin Male Input Ground Shield Pin 1 Pin 1 DMX Data Pin 2 Pin 2 DMX Data Pin 3 Pin 3 Not Us...

Страница 9: ...arily the fixtures that follow may also re quire a slave setting Check the Operating Adjustments section in this manual for com plete instructions for this type of setup and configuration Mounting Rig...

Страница 10: ...lls through menu items and numbers in ascending order DOWN Scrolls through menu items and numbers in descending order ENTER Is used to select and confirm store the current selection The Control Panel...

Страница 11: ...15 FLAS FL00 FL15 Flash strobe speed 0 15 rL r000 r255 Red dimmer 0 100 GL G000 G255 Green dimmer 0 100 bL b000 b255 Blue dimmer 0 100 AL A000 A255 Amber dimmer 0 100 UL U000 U255 White dimmer 0 100 u...

Страница 12: ...Allows a single or Master Slaved units to run factory installed programs at user selectable speeds Auto Mode 1 Navigate the menu using the UP DOWN button until you reach ASC 2 Push the ENTER button 3...

Страница 13: ...7 099 100 102 103 105 106 108 109 111 Static Colors Auto Mode Dimming Red Green Blue Amber White UV R G R B R A R W R UV G B G A G W G UV B A B W B UV A W A UV W UV R G B R G A R G W R G UV R B A R B...

Страница 14: ...hat It Does 1 000 255 Red Intensity 0 100 2 000 255 Green Intensity 0 100 3 000 255 Blue Intensity 0 100 4 000 255 Amber Intensity 0 100 5 000 255 White Intensity 0 100 6 000 255 UV Intensity 0 100 7...

Страница 15: ...heck AC cord and circuit for damage verify that moving parts are not restricted and that unit s ventilation is not obstructed Slow Movement Verify that 220V 110V switch is in the correct position if a...

Страница 16: ...pical 3 pin mic cables although this does not conform to the defined standard DMX is connected using a daisy chain configuration where the source connects to the input of the first device the output o...

Страница 17: ...ent s satisfaction and wow factor That s what it s all about after all Returns Gasp We ve taken a lot of precautions to make sure you never even have to worry about sending a defective unit back or s...

Страница 18: ...1 LEDs 100 000 hours Optical Beam Angle 25 degree Luminous Intensity Lux m Red Green Blue Amber White UV ALL 1m 2 566 3 054 2 950 1 687 4 730 825 13 700 2m 722 914 885 500 1 276 250 3 900 Thermal Max...

Страница 19: ...Page 19 TOURnado IP EXA User Manual Rev B Copyright 2014 Blizzard Lighting LLC 10 7 in 270 1 mm 6 6 in 166 mm 8 6 in 218 1 mm Dimensional Drawings 11 2 in 283 7 mm 5 7 in 144 mm...

Страница 20: ...Enjoy your product Our sincerest thanks for your purchase The team Blizzard Lighting...

Отзывы: