background image

19

20

6.

  Measure the vertical distances between marks 

d1=a1-a2, d2=a1-a3

 that indicate the 

actual deviation of the instrument.

If any of the actual deviations is greater than the Allowable Deviation for the corresponding 

Distance to Wall in the following table, the instrument must be serviced.

Distance to Wall

Allowable Deviation

16' (5m)

5/32" (4mm)

30' (9m)

5/16" (8mm)

Step 3:

 Checking the Leveling Accuracy of the Vertical Line

For this check, the most practical recommendation is to consider a door opening with  

at least 7' (2m) of height clearance and 8' (2,5m) of space to each side of the opening.

1.

  Position the instrument directly on a firm, level floor surface 8' (2,5m) away from  

the door opening.

2.

  Turn on the instrument in the self-leveling mode by sliding the Pendulum Switch 

 2 

  

to the UNLOCK position.

3.

  Direct the vertical laser beam to the center of the opening and allow a few seconds  

for the visible laser line to stabilize.

4.

  Mark the center of the vertical laser line projected by the instrument in three locations: 

on the floor at the center of the door opening 

(point a)

, at an 8' (2,5m) distance beyond 

the other side of the door opening 

(point b)

, and at the upper edge of the door opening 

(point c1).

8' 

(2,

5m

)

8' 

(2,

5m

)

b

c1

a

 7

' (

2

m

)

Содержание TB-H2-LL-30-L2

Страница 1: ...2 OPERATING SAFETY INSTRUCTIONS IMPORTANT Read all safety warnings and instructions before using ToughBuilt Industries Inc 6671 S Las Vegas Blvd Building D Suite 210 Las Vegas NV 89119 USA Made in Chi...

Страница 2: ...specifications and general appearance of the instrument are subject to change without notice and without obligation by ToughBuilt Industries Inc and may differ from those appearing in this manual TAB...

Страница 3: ...for people who are wearing prescription glasses lenses DO NOT use this laser device for anything other than its intended purpose DO NOT disassemble or modify the device Tampering with this device may...

Страница 4: ...he battery avoid contact If contact accidentally occurs flush with water If liquid contacts the eyes additionally seek medical help Liquid ejected from the battery may cause serious injury Work Area S...

Страница 5: ...to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception w...

Страница 6: ...N When moving the instrument from a warm environment into a cool environment moisture may accumulate on the Laser Beam Window 1 Allow the instrument to adapt to the new environment first DO NOT turn o...

Страница 7: ...plications or Pendulum Locked Mode for inclined applications Powering ON OFF in the Self Leveling Mode In this mode the laser beam self levels within 4 to project horizontal and vertical laser lines 1...

Страница 8: ...is completely separated from the bracket Only use ToughBuilt accessories that are designed for this product Contact ToughBuilt Customer Service for additional support 4 ACCURACY CHECK This instrument...

Страница 9: ...to a tripod close to wall A 2 Turn on the instrument in the self leveling mode by sliding the Pendulum Switch 2 to the UNLOCK position 3 Direct the laser beam against wall A and allow a few seconds fo...

Страница 10: ...n wall B B A b a1 9 Without changing the height rotate the instrument 180 to direct the laser beam toward wall A 10 Allow the instrument to self level and mark the center of the horizontal line on wal...

Страница 11: ...m Switch 2 to the UNLOCK position 3 Direct the laser beam against wall A Pos 1 and allow a few seconds for the visible line to stabilize Mark the center of the horizontal line projected by the instrum...

Страница 12: ...st 7 2m of height clearance and 8 2 5m of space to each side of the opening 1 Position the instrument directly on a firm level floor surface 8 2 5m away from the door opening 2 Turn on the instrument...

Страница 13: ...Batteries are not inserted Insert 3 x AA batteries Incorrect battery polarity Check battery polarity Low charge or depleted batteries Replace with new batteries Corroded battery terminals Clean the b...

Страница 14: ...ore the instrument in its original container if one is available DO NOT leave the instrument in direct sunlight or expose it to high or cold temperatures see the recommended Operating temperatures DO...

Страница 15: ...ation 1 Visit https toughbuilt com register your product or scan the QR code below to begin the product registration 2 Fill in the form and upload the proof of purchase For product registration suppor...

Страница 16: ...27 28...

Отзывы: