NOTE:
If the instrument is tilted beyond its self-leveling limits (± 4°), the Pendulum
Locked Indicator
4
will flash and the laser beam will rapidly flash. Reposition the
instrument until the beam stabilizes and the indicator stops flashing.
3.
To power OFF, slide the Pendulum Switch
2
to the LOCK position and press the Power
ON/OFF Button
5
.
Powering ON/OFF in the Pendulum-Locked Mode:
In this mode, the self-leveling capability is disabled, and the laser level can be tilted to
project horizontal and vertical laser lines at an incline.
1.
Press the Power ON/OFF button
5
for three seconds to activate the laser.
2.
Pendulum Locked Indicator
4
will flash and the laser beam will slowly flash
(approx. every 6 seconds).
3.
To power OFF, press the Power ON/OFF Button
5
.
3. HOW TO OPERATE
CAUTION!
When moving the instrument from a warm environment into a cool environment,
moisture may accumulate on the Laser Beam Window
1
. Allow the instrument to adapt to
the new environment first.
DO NOT
turn on a wet or damp instrument. To wipe the Laser
Beam Window
1
, use
ONLY
a lint-free cloth.
DO NOT USE A PAPER TOWEL.
PLEASE NOTE:
Laser beam expands as the distance between the instrument and the target
increases. Therefore, always take measurements in the center of the laser line.
Installing the Batteries
Before installing or replacing the batteries, make sure that the Pendulum Switch
2
is in the LOCK position, and the power is turned OFF.
1.
Open the Battery Compartment Cover
8
by pushing the latch
7
and lifting it.
2.
Insert the batteries observing the polarity. Ensure that the removal band is positioned
under the batteries.
3.
Close the Battery Compartment Cover
8
until it engages.
Powering ON/OFF:
The instrument can be used in either a
Self-Leveling Mode
(for level applications) or
Pendulum-Locked Mode
(for inclined applications).
Powering ON/OFF in the Self-Leveling Mode:
In this mode, the laser beam self-levels within ± 4° to project horizontal and vertical laser lines.
1.
Before powering ON, place the instrument on a firm and level surface.
2.
Slide the Pendulum Switch
2
to the UNLOCK position to activate the laser and wait until
it stabilizes.