background image

Option 4 - Courtesy Light

 

Output #7 turns ON for 20-seconds whenever output #1 is activated. 
Switch Input A1 controls output #1
Switch Input A2 turns OFF all outputs as long as it is active.

PowerTouch Remote Control Systems - 1000 Series (2 - 6) Functions

Page -2-

ON

OFF

Receiver

1

Operation

Out
# 1

ON

OFF

DIP Switch 7 - OFF
DIP Switch 8 - OFF

DIP Switch 7 - OFF
DIP Switch 8 - ON

Option 2 - Hydraulic Pump

 

Output #7 is ON anytime outputs 1 - 6 are active.
Switch Input A1 controls output #1
Switch Input A2 controls output #2

DIP Switch 7 - ON
DIP Switch 8 - OFF

Option 3 - Cascade

Output #7 turns ON for 2-seconds whenever output #1 is activated.
Switch Input A1 controls output #1
Switch Input A2 controls output #2

DIP Switch 7 - ON
DIP Switch 8 - ON

DIP Switches 7 & 8

Transmitter Styles

Receiver

Connection

 Schematic

DIP switch

located inside

 receiver enclosure

Signal Transmissions

  Standard - Press & Release Button
    No maximum signal duration

  Option - Multi-channel signal

Status LED

  Standard - One flash per second transmitting

 - No flash if low battery

Inputs (DIP switch programmable)

Switch Input A1
Switch Input A2

Outputs (DIP switch programmable)

1

Momentary or Latching

2

Momentary or Latching

3

Momentary or Latching

4

Momentary or Latching

------------------------------------------------------
5

Momentary or Latching

6

Momentary or Latching

7

See DIP Switch Options Below

ENROLLING NEW TRANSMITTERS - Self-Learning Receiver

1.  Remove cover from receiver enclosure.
2.  Locate LEARN switch (small, square push-button style switch located in the 
corner of the printed circuit board).
3.  Press and release the LEARN switch and observe LEARN LED (next to 
LEARN switch).
4.  LED is flashing when unit is in LEARN Mode and new codes can be 
enrolled.
5.  When LEARN LED is flashing, press any button on transmitter.
6.  LEARN LED blinks to confirm enrollment.  Release transmitter button.
7.  Press any button on the new transmitter to confirm that the new code has 
been enrolled.  
8.  Replace receiver enclosure cover.

Output 7
J2-14

Output 6
J2-13

Output 5
J2-12

Output 4
J2-11

Output 2
J2-9

Output 3
J2-10

Output 1
J2-8

Switch Input A2, J2-2

NO INP BUS, J1-1 

(Optional: Typ PWR)

NO INP BUS, J2-6
NO INP BUS, J2-7

Switch Input A1, J2-1

Logic Power, J2-4

Logic Ground, J2-3

DIP Switch Options

ON

OFF

Out
# 3

Out
# 2

Out
# 4

Out
# 5

Out
# 6

2

3

4

5

6

7

8

7

8

ON

OFF

7

8

ON

OFF

7

8

ON

OFF

7

8

ERASING ALL ENROLLED TRANSMITTERS

1.  Press and hold the LEARN switch.
2.  LEARN LED will flash rapidly for about 10 seconds, 
followed by two long flashes.
3.  Release LEARN switch.
4.  All transmitter codes are now erased.

Optional Enrolling Method

1.  Remove and reconnect power to unit.  This will place unit 
into LEARN mode for 5-seconds.
2.  Press any button on transmitter.  Wait 5-seconds and confirm 
the transmitter has been enrolled by pressing any button and 
verifying the correct output turned ON.

4-Relay
Models

7-Relay
Models

DIP Switches 1 - 6 control outputs 1 - 6 respectively:

     OFF = Momentary
     ON = Latching

L

O

G

IC

Option 1 - Direct Switch Inputs

Switch Input A1 controls output #1
Switch Input A2 controls output #2

Standard - Large Key Fob
    2, 4 & 6 Button

Option - Large Oval Hand-Held
    2, 4 & 6 Button

    (Power Switch Optional)

Option- Small Key Fob
    1, 2 & 4 Button

Option - Mini Key Fob
    1, 2 & 4 Button

Photos Not To Scale

Содержание POWERTouch 1010-R

Страница 1: ...n Mini key fob 4 button 1000 Series Receiver Specifications Voltage 9 16 Volt DC 12 Volt DC Nominal 24 Volt DC Optional Current 5A Output 10A System Max Switch Inputs 2 6 Additional Optional Outputs 4 or 7 Frequency 433 MHz Antenna Standard Fixed Optional Removable 6 Whip TNC Exterior 14 Cable 1000 Series System Specifications Range Pulsed 100 Feet Typical 300 Feet Clear Field Range Continuous 50 ...

Страница 2: ...ted circuit board 3 Press and release the LEARN switch and observe LEARN LED next to LEARN switch 4 LED is flashing when unit is in LEARN Mode and new codes can be enrolled 5 When LEARN LED is flashing press any button on transmitter 6 LEARN LED blinks to confirm enrollment Release transmitter button 7 Press any button on the new transmitter to confirm that the new code has been enrolled 8 Replace...

Страница 3: ...UT INPUT INPUT INPUT INPUT INPUT INPUT INPUT INPUT N A N A 500mA 500mA 5 A 5 A 5 A 5 A 5 A 5 A 5 A 5 A 5 A 5 A 30 A 30 A Installation OPTIONAL J1 POWER CONNECTOR Antenna Installation 1 The antenna must be installed in an open non metal area in order to receive RF radio frequency transmissions 2 RF transmissions are reduced if antenna is A within 6 feet of a large motor B near large bundles of wire...

Страница 4: ...reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures 1 reorient or relocate the receiving antenna 2 increase the separation between the equipment and the receiver 3 connect the equipment to an outlet on a circuit different from that to which the receiver is connected 4 consult the de...

Отзывы: