Freeze Damage Prevention
When the ambient temperature is likely to drop to 0 C or lower, take measures to prevent freezing.
Attention!
• When the ambient temperature is likely to drop to 0 C or lower, do not use the energy saver feature.
(May damage the product.)
• Warm the bathroom or take measures against freezing so that the ambient temperature does not drop below 0 C.
• Before starting work, set "AUTO FLUSH" (only when "FLUSH" button is located on the top side of the remote control)
(Page 38) and "Auto open/close" (Page 40) to "OFF".
How to freeze damage prevention
1
Close the shutoff valve.
(Page 35 Step
1
)
• The water supply stops.
CAUTION
Do not remove the water
fi
lter
drain valve while the shutoff
valve is open.
(Otherwise, water may leak out.)
2
Drain the water from the toilet
tank.
• Manipulate the lever/button/etc. until the
water stops.
3
Press
"Wand CLEAN" button.
• Open the wand cover.
(Release the pressure from the water
supply pipe.)
4
Switch the breaker on the
distribution board to OFF.
5
Drain the pipe.
①
Remove the cover and water
fi
lter drain
valve.
• Loosen the water
fi
lter drain valve with
a
fl
at-head screwdriver and then pull it.
Water Filter
Drain Valve
Flat-head screwdriver
Cover
②
Drain the water from the water supply hose.
Water supply hose
Horizontally
③
After draining the water, install the water
fi
lter drain valve and cover.
• Insert the water
fi
lter drain valve and
use a
fl
at-head screwdriver to tighten it
securely.
6
Switch the breaker on the
distribution board to ON.
• The "Power" LED lights up.
7
Set the toilet seat temperature
to "High".
(Page 24)
• To maintain the temperature, close the
toilet seat and toilet lid after
fi
nishing work.
■
To use the product again
• The water needs to be resupplied. (Page 58)
57
Reference