*GCFI Outlet Min.

12" off floor

*The 3-prong cord on the Washlet is on the right side and is 4' long.

The GFCI outlet needs to have120V, 10amps.

5 1/2"

[140mm]

15 3/8"

[391mm]

20 7/8"

[531mm]

7 3/8"

[188mm]

5/16"

[8mm]

1 1/2"

[38mm]

Elongated

•  Power Rating:

 

  AC 120V-60Hz, 406W 

•  Power Cord:

 

   Maximum  length:   
    3.94 ft/120 cm, 3 prong     
    grounded plug

•  Water Feature:

 

  Adjustable Water  

 

  Flow Rate:

 

 

  Front washing - 

 

 

  9.8-14.5 oz/min 

 

 

  Rear washing - 

 

 

  9.1 -14.5 oz/min

 

 

  Soft Rear - from 

•   

  9.1 -14.5 oz/min 

Washing Spray Temp:

   Minimum:  95°F/35°C 

Maximum: 104˚F/40˚C

•  Safety Device:

 

   Thermal  fuse.

•  Drying Feature:

 

   Air  temperature: 
    High: about 140ºF/60ºC 
    Low: about 86ºF/30ºC

•  Dryer Air Volume:

   9.53ft

3

/min

•   

Seat Warming Feature:

  Surface  Temperature: 
Minimum: 82˚F/28˚C 
Maximum: 97˚F/36˚C

•  Safety Device:

  

  Thermal fuse

•   Water Supply Pressure:

Minimum: 7.25 psi 

 

  Maximum: 108.75 psi

•   

Ambient Temperature:

 Range:

 

 

  33˚F/1˚C to 104˚F/40˚C

•  Warranty:

 

   One Year Limited Warranty

•  Shipping dimensions:

  23 ½” x 19” x 9”

•  Shipping weight:

  

  16lbs

SPECIFICATIONS

SW2044T20

Washlet

®

 C200

# SS-01115 v.02

Ph: (888) 295-8134 | Fax: (800) 699-4889 | www.totousa.com | 

© TOTO USA

 

INSTALLATION NOTES

•  Washlet C200 is designed to fit 

TOTO toilet bowl models only!

These dimensions and specifications are subject to change without notice

*GCFI Outlet Min.

12" off floor

*The 3-prong cord on the Washlet is on the right side and is 4' long.

The GFCI outlet needs to have120V, 10amps.

5 1/2"

[140mm]

15 3/8"

[391mm]

20 7/8"

[531mm]

7 3/8"

[188mm]

5/16"

[8mm]

1 1/2"

[38mm]

Elongated

It is highly recommended to use a surge protector to 
prevent damage in the event of a power surge.

COMPATIBLE WITH TOILETS

TOILETS

 MODEL NUMBER

 KIT NUMBER

ULTRAMAX  II  1G                                   

CST604CUFGT20#01

MW6042044CUFG#01

ULTRAMAX II

CST604CEFGT20#01

MW6042044CEFG#01

CARLYLE II 1G

CST614CUFGT20#01

MW6142044CUFG#01

CARLYLE II

CST614CEFGT20#01

MW6142044CEFG#01

SUPREME II

CST634CEFGT20#01

MW6342044CEFG#01

CAROLINA II

CST644CEFGT20#01

MW6442044CEFG#01

DRAKE II 1G
Tank: ST453U

C454CUFGT20#01

MW4542044CUFG#01

DRAKE II
Tank: ST454E

C454CUFGT20#01

MW4542044CEFG#01

VESPIN II 1G
Tank: ST453U

CT474CUFGT20#01..

MW4742044CUFG#01

VESPIN II
Tank: ST454E

CT474CUFGT20#01

MW4742044CEFG#01

*GCFI Outlet Min.

12" off floor

*The 3-prong cord on the Washlet is on the right side and is 4' long.

The GFCI outlet needs to have120V, 10amps.

5 1/2"

[140mm]

15 3/8"

[391mm]

20 7/8"

[531mm]

7 3/8"

[188mm]

5/16"

[8mm]

1 1/2"

[38mm]

Elongated

Отзывы: