![Toto Washlet C200 Connect+ Series Скачать руководство пользователя страница 2](http://html1.mh-extra.com/html/toto/washlet-c200-connect-series/washlet-c200-connect-series_manual_1140041002.webp)
*GCFI Outlet Min.
12" off floor
*The 3-prong cord on the Washlet is on the right side and is 4' long.
The GFCI outlet needs to have120V, 10amps.
5 1/2"
[140mm]
15 3/8"
[391mm]
20 7/8"
[531mm]
7 3/8"
[188mm]
5/16"
[8mm]
1 1/2"
[38mm]
Elongated
• Power Rating:
AC 120V-60Hz, 406W
• Power Cord:
Maximum length:
3.94 ft/120 cm, 3 prong
grounded plug
• Water Feature:
Adjustable Water
Flow Rate:
Front washing -
9.8-14.5 oz/min
Rear washing -
9.1 -14.5 oz/min
Soft Rear - from
•
9.1 -14.5 oz/min
Washing Spray Temp:
Minimum: 95°F/35°C
Maximum: 104˚F/40˚C
• Safety Device:
Thermal fuse.
• Drying Feature:
Air temperature:
High: about 140ºF/60ºC
Low: about 86ºF/30ºC
• Dryer Air Volume:
9.53ft
3
/min
•
Seat Warming Feature:
Surface Temperature:
Minimum: 82˚F/28˚C
Maximum: 97˚F/36˚C
• Safety Device:
Thermal fuse
• Water Supply Pressure:
Minimum: 7.25 psi
Maximum: 108.75 psi
•
Ambient Temperature:
Range:
33˚F/1˚C to 104˚F/40˚C
• Warranty:
One Year Limited Warranty
• Shipping dimensions:
23 ½” x 19” x 9”
• Shipping weight:
16lbs
SPECIFICATIONS
SW2044T20
Washlet
®
C200
™
# SS-01115 v.02
Ph: (888) 295-8134 | Fax: (800) 699-4889 | www.totousa.com |
© TOTO USA
INSTALLATION NOTES
• Washlet C200 is designed to fit
TOTO toilet bowl models only!
These dimensions and specifications are subject to change without notice
*GCFI Outlet Min.
12" off floor
*The 3-prong cord on the Washlet is on the right side and is 4' long.
The GFCI outlet needs to have120V, 10amps.
5 1/2"
[140mm]
15 3/8"
[391mm]
20 7/8"
[531mm]
7 3/8"
[188mm]
5/16"
[8mm]
1 1/2"
[38mm]
Elongated
It is highly recommended to use a surge protector to
prevent damage in the event of a power surge.
COMPATIBLE WITH TOILETS
TOILETS
MODEL NUMBER
KIT NUMBER
ULTRAMAX II 1G
CST604CUFGT20#01
MW6042044CUFG#01
ULTRAMAX II
CST604CEFGT20#01
MW6042044CEFG#01
CARLYLE II 1G
CST614CUFGT20#01
MW6142044CUFG#01
CARLYLE II
CST614CEFGT20#01
MW6142044CEFG#01
SUPREME II
CST634CEFGT20#01
MW6342044CEFG#01
CAROLINA II
CST644CEFGT20#01
MW6442044CEFG#01
DRAKE II 1G
Tank: ST453U
C454CUFGT20#01
MW4542044CUFG#01
DRAKE II
Tank: ST454E
C454CUFGT20#01
MW4542044CEFG#01
VESPIN II 1G
Tank: ST453U
CT474CUFGT20#01..
MW4742044CUFG#01
VESPIN II
Tank: ST454E
CT474CUFGT20#01
MW4742044CEFG#01
*GCFI Outlet Min.
12" off floor
*The 3-prong cord on the Washlet is on the right side and is 4' long.
The GFCI outlet needs to have120V, 10amps.
5 1/2"
[140mm]
15 3/8"
[391mm]
20 7/8"
[531mm]
7 3/8"
[188mm]
5/16"
[8mm]
1 1/2"
[38mm]
Elongated