Toto RYOHAN TEL3GMY Скачать руководство пользователя страница 2

10-1/4”

(260mm)

1-1/4”

(159mm)

1-1/8”

(30mm)

8-5/8”

(218mm)

6”

(152mm)

Water

Supply

Single Supply

Controller

  2-3/8”

(60mm)

60

  7-5/16”

(186 mm)

  2” (50 mm) to

  5” (127 mm)

   ~ 33” 

(838 mm) 

overall

length

 Ø4x40

3 screws

with anchors

1-3/4”(45mm)

Faucet

6-5/8”

(168mm)

8-1/8”

(207mm)

2-3/4”

(70mm)

10-1/4”

(260mm)

1-1/4”

(159mm)

1-1/8”

(30mm)

8-5/8”

(218mm)

6”

(152mm)

Water

Supply

Single Supply

Controller

8

Please confirm the basin dimension of lavatory, to

which the faucet will be installed, making sure that it

has recommended minimum dimensions of

(L x W: 15" x 15").

Faucet Hole Diameter

Min. 28mm (~1-1/16”)

to

Max. 35mm (~1-3/8”)

Before Installing

1. Check the pressure of cold and hot water supply

2. Piping

3. Others

When the water supply pressure is higher than 125PSI (862kPa), be sure to

reduce the pressure within a range of 20 to 80 PSI by using a pressure

reducing valve available in the market.

Optimum working pressure range is from 14.5PSI to 125PSI (100kPa to 

862kPa). Make sure the water pressure is within this range.

Flush all water lines prior to installation.

Pay special attention so that the sensor surface is not flawed or scratched.

Prepare stop valve and flexible hose or copper tube.

Do not place other devices using inverter or infrared sensor near the

Automatic Faucet, this may cause malfunction.

There is no problem with the Automatic Faucet if water remains inside.

Set-up Drawing

Some models may have different components as illustrated below.

Battery type

  Ryohan™

Battery type

Helix™ Wall Mount

Содержание RYOHAN TEL3GMY

Страница 1: ...utomatic Faucet This may cause damage or water leakage Never attempt to disassemble reassemble repair or modify the Automatic Faucet unless you are an electrician or qualified service person This may cause property damage or personal injury Do not disassemble Do not strike Specification EcoPower type Model number Power supply Battery life Item Detection range from the sensor 5 1 8 7 7 8 130 200 mm...

Страница 2: ...er supply 2 Piping 3 Others When the water supply pressure is higher than 125PSI 862kPa be sure to reduce the pressure within a range of 20 to 80 PSI by using a pressure reducing valve available in the market Optimum working pressure range is from 14 5PSI to 125PSI 100kPa to 862kPa Make sure the water pressure is within this range Flush all water lines prior to installation Pay special attention s...

Страница 3: ...ruction manual Others Allen wrench Size 1 16 2mm Spout Flexible tube and Open close tool are included RYOHAN Spout Flexible tube Open close tool Others Flexible tube is installed through spout connecting hose EcoPower type RYOHAN Screw φ3 mm 10 Helix Wall Mount Spout Flexible tube Open close tool Others Flexible tube is installed through spout connecting hose Helix Wall Mount 3 Phillip Screws Ø4x4...

Страница 4: ...away any foreign matter such as dirt and sand trapped in the water supply pipe STEP 2 Remove the controller cover Pull and open the controller cover to the direction as shown right STEP 3 A Mount the water inlet bracket on the wall Mount the water inlet bracket on the wall and temporarily tighten the screws Make sure that the controller can be attached to the water inlet bracket Tighten the water ...

Страница 5: ...cut the hose carefully with a cutter so the surface is square Insert the spout connecting hose into the flexible tube Clean the hose end after cutting Spout connecting hose Cutting length 4 inches or less 90 Spout connecting hose Flexible tube Remove the Permanent Flow Valve Pull out the pinch of the stop ring then remove the permanent flow valve Remove Permanent Flow Valve Stop Ring Pull out this...

Страница 6: ... spout direction will need to be readjusted for proper operation Sensor Sensor light Back up battery connector white Sensor connector Green Caution STEP 8 Fasten the spout Ryohan Affix the spout by tightening the hexagonal nut Be sure to mount the faucet body with its spout tip directed toward the basin center Caution Spout position On the right side Drain Spout Basin center STEP 8 Install the spo...

Страница 7: ...unit in 2 Turn the drain cup counter clockwise making the cross bar align with the notches in the angles Main Drain Body Drain cup Unit Cross bar Angle Drain cup unit Main Drain Body Notch Cross Bar Angle Notch drain cup unit Click Push the drain cup in until you hear a click Pull Firmly Drain cup Part STEP 9 Attach the controller cover STEP 10 Install the Drain After checking the connectors are s...

Страница 8: ...atic Faucet may not operate properly 3 Adjustment of flow rate The flow controller regulates flow rate to 0 8gpm 3 L min there is no need to adjust the flow rate Use the Automatic Faucet with the stop valve fully opened However if you need to regulate the flow rate because the wash basin is small or that the water supply pressure is too strong adjust the flow rate by turning the stop valve clockwi...