Toto Helix EcoPower TEL5GW CP Series Скачать руководство пользователя страница 1

Do not.

Do not use the Automatic Faucet at temperatures

what local codes allow.

INSTALLATION MANUAL

AUTOMATIC FAUCET

Thermal mixing valve faucet

Important Safeguards

(For your safety, please follow the instructions below.)

 In this Instruction Manual, the following symbols are shown for safe and proper use

of your automatic faucet and in order to alert you to the possibility of personal injury

and damage to your property.

The symbols and their meanings are as follows.

Warning

Ignoring these symbols may cause

personal injury and/or property damage.

*Some models may have different components from the ones illustrated below.

Do not place the Automatic Faucet in a high humidity

area such as shower room or sauna.

 

This may cause damage.

Do not use in

humid area

Warning

Do not strike or kick the Automatic Faucet.

This may cause damage or water leakage.

Never attempt to disassemble, reassemble, repair

or modify the Automatic Faucet, unless you are an

electrician, or qualified service person.

This may cause property damage or personal injury.

Do not

disassemble

Do not strike

Specification

0GU3014ER

2007.03

EcoPower    

type

Model

number

Power supply

-

-

Battery life

Item

Detection range

from the sensor

5-1/8"~7-7/8" (130~200 mm)

sensor is self-adjusting

Water supply

pressure

minimum required water pressure:

14.5 PSI (100 kPa) ( Flowing)

maximum water pressure:

125 PSI (862 kPa)

check local building codes for maximum water

pressure allowed

Water supply connection

1/2" NPSM

RYOHAN™

TEL5GMY

Ambient temperature

32~104

o

F(0~40

o

C)

Humidity

Max. 90% RH

Flow rate

0.8 gallon per minutes (3 L/min.) 

Duration of

water discharge

Discharge quantity

Max. 0.25 gallon per cycle (0.95 L/cycle) 

60 seconds (TEL5             - 60)

   

   

Helix™ Wall Mount

TEL5GW#CP

Содержание Helix EcoPower TEL5GW CP Series

Страница 1: ...area Warning Do not strike or kick the Automatic Faucet This may cause damage or water leakage Never attempt to disassemble reassemble repair or modify the Automatic Faucet unless you are an electric...

Страница 2: ...pecial attention so that the sensor surface is not flawed or scratched Prepare stop valve and flexible hose or copper tube Do not place other devices using inverter or infrared sensor near the Automat...

Страница 3: ...manual Others Allen wrench Size 1 16 2mm Spout Flexible tube and Open close tool are included RYOHAN Spout Flexible tube Open close tool Others Flexible tube is installed through spout connecting hos...

Страница 4: ...et brackets on the wall Mount the water inlet brackets on the wall and temporarily tighten the screws The distance between the water inlet brackets shall be 3 3 4 95mm The controller and the two brack...

Страница 5: ...ry Cut the spout connecting hose to the appropriate length If the spout connecting hose is too long cut it to proper length Do not cut the hose more than 4 inches Be sure to cut the hose carefully wit...

Страница 6: ...is completed in approx 20 seconds Make sure that no electric cord comes in contact with the hot water supply pipe EcoPower type needs about two minutes for its controller to be ready for operation aft...

Страница 7: ...he drain cup is accidentally removed begin the process over from the beinning 1 Insert the drain cup into the main drain body 3 Pull firmly on the drain cup unit being careful not to remove it then re...

Страница 8: ...adjust the flow rate by turning the stop valve clockwise The EcoPower type must be used with the stop valve fully opened Insufficient flow rate may cause power shortage resulting in consumptionof the...

Отзывы: