3.2 SPACE REQUIREMENT FOR OUTDOOR
>30cm
>30cm
>200cm
>60cm
(Wall or obstacle)
Maintain channel
Air outlet
Air inlet
M
P
Air inlet
N
>60cm
Fix with bolt
Single Unit Installation
>200
>50
>300
>300
>30
>60
>200
>30
Parallel connect the two units or above
Parallel connect the front with rear sides.
unit:cm
unit:cm
Step 4: Connect Pipe
L
N
S
Step 5: Connect Wire
Step 6: Prepare Drain Hose
STEP
8
Indoor Wire Connection
1. Lift the indoor unit front panel.
2. Open the indoor unit electrical cover with a screwdriver through
the hole, remove the terminal block cover by hand and remove
the cable clamp by loosening the screws
3. Pass the connecting wires from the back of indoor unit and
connect to the indoor terminal block.
Front panel
The drain line must not have a trap anywhere in its length,
must pitch downwards, and must be insulated up to the
outside wall.
Drainage
Do not put drain end into water
Proper
Do not form a rise
Step 7: Wrap Pipe and Cable
Step 8: Hang the Indoor Unit
1. Run refrigerant lines through hole in the wall.
2. Hang indoor unit on upper hook of mounting plate, then push
lower part of indoor unit up on wall to lower hook.
3. Move indoor unit from side to side, up and down to check if it is
hooked securely.
Use a wedge to prop up the unit if rear tubing is needed.
Hang The Indoor Unit
For proper orientation of the refrigerant piping, electrical cable
and drain lines, refer to below Fig:
- Place the drain hose below the refrigerant piping.
- Make sure that the drain hose is not heaved or snaked.
- Au lines must be separately insulated.
Wrap The Pipe
Indoor unit
Electrical
cable
Drain hose
Heat insulation
type
Refrigerant piping
Pipe room
Ponding box
The mounting dimensions vary among different outdoor units.
The fixing bolt head diameter should be more than 12mm.
W
H
B
A
D
Outdoor Unit Dimentsion (mm)
Mounting Dimentsion (mm)
W
H
D
A
B
700
550
275
450
267
300
333
363
555
554
702
770
800
845
487
515
540
298
340
376
In regions with snowfall and cold temperatures, avoid installing the outdoor unit in areas where it can be covered by
snow. If heavy snow is expected, a field supplied ice or snow stand and/or field supplied-installed wind baffle should be
installed to protect the unit from snow accumulation and/or blocked air intake.
CAUTION
Outdoor Unit
TOU012DS
TOU018DS
TOU024DS
2
.
INDOOR UNIT INSTALLATION
3. OUTDOOR UNIT INSTALLATION
3.1 OUTDOOR UNIT MOUNTING DIMENSION
Electrical cover
Open the cover
from this hole
Connector for wired controller
(optional,come out from display box)
Electrical cover
Terminal Block Cover
Cable Clamp
30
Wedge
T
T
T
G B