background image

Manufacturer reserves the right to

discontinue, or change at any time,

specifications or designs without notice

and without incurring obligations.

REPLACEMENT COMPONENTS DIVISION
© CARRIER CORPORATION  3/01 

LITERATURE NUMBER AC-1SI

PRINTED IN U.S.A.

CATALOG NUMBER 570-617

Part Numbers: P102-BB14A, P102-BB20

IF YOU NEED HELP call toll free: 1-800-267-8305

CONTENTS

SAFETY CONSIDERATIONS

   . . . . . . . . . . . . . . . . . . . . . 1

GENERAL

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1

COMPONENTS

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1,2

Cabinet

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1

Filter

 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1

INSTALLATION

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2,3

Location

 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2

Media Air Cleaner Installation

 . . . . . . . . . . . . . . . . . . . . 2

OPERATION

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4

MAINTENANCE

 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4

Filter Replacement

 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4

SAFETY CONSIDERATIONS

Read and follow manufacturer instructions carefully. Im-

proper installation may damage media air cleaner.

Recognize safety information. This is the safety alert sym-

bol 

 . When the safety alert symbol is present on equipment

or in the instruction manual, be alert to the potential for person-
al injury.

Understand the signal words DANGER, WARNING, and

CAUTION. These words are used with the safety alert symbol.
DANGER identifies the most serious hazards which will result
in severe personal injury or death. WARNING signifies a haz-
ard which could result in personal injury or death. CAUTION
is used to identify unsafe practices which would result in minor
personal injury or property damage.

Installation and servicing of air-conditioning equipment can

be hazardous due to system pressure and electrical compo-
nents. Only trained and qualified service personnel should in-
stall, repair, or service air-conditioning equipment.

Untrained personnel can perform the basic maintenance

functions of replacing filters. All other operations should be
performed by trained service personnel. When working on air-
conditioning equipment, observe precautions in the literature,
tags and labels attached to the unit, and other safety precautions
that may apply.

Follow all safety codes. Wear safety glasses and work

gloves.

GENERAL

The Builder’s Box Media Air Cleaner is designed to re-

move atmospheric and household dust, pollen, mold spores,
bacteria, fungi, insecticide dust, animal dander, coal dust,
mites, cooking smoke and grease, tobacco smoke, and other
particles down to 0.3 micron (1/84,000 in.)

Airborne pollutants are carried through the return air ducts

of the heating/cooling system to the media air cleaner. The par-
ticles are captured by the filter.

The media air cleaner can be easily upgraded to an electronic

air cleaner for additional air filtration. Additional clearance
above the media air cleaner is required for electronic air cleaner
upgrade.

Regular maintenance (replacement of filters) is required by

the home owner.

COMPONENTS

See Fig. 1 for a description of the media air cleaner. See

Table 1 for media air cleaner specifications.

Cabinet — 

The cabinet is constructed of heavy gage galva-

nized steel. Holes are provided in the cabinet for easy mounting
in the ductwork or air-handling equipment. See Fig. 2 for cabi-
net dimensions.

Filter — 

The filter is constructed of polyolefin fibers that

will not shred or absorb moisture. The unique design of the fil-
ter includes a structured density gradient with a polarized
charge for higher initial and sustained efficiency. The filter me-
dia is supported by an open steel mesh and enclosed by a high
strength, beverage board. The filters have an Underwriters’
Laboratories Class 2 rating.

The efficiency of the filter is based on ASHRAE (American

Society of Heating, Refrigeration and Air Conditioning Engi-
neers) Standard 52.2P. The maximum velocity is 500 ft/min.
An arrow indicates direction of airflow.

IMPORTANT: Read entire instructions before
installing the builder’s box media air cleaner.

Before beginning any installation or modification, be cer-
tain that the main line electrical disconnect switch is in the
OFF position. Electric shock could result. Tag disconnect
switch with suitable warning labels.

INSTALLATION,
OPERATION, AND 
MAINTENANCE
INSTRUCTIONS

Residential Duct Mount

Builder’s Box

Media Air Cleaner

Содержание P102-BB14A

Страница 1: ...rk gloves GENERAL The Builder s Box Media Air Cleaner is designed to re move atmospheric and household dust pollen mold spores bacteria fungi insecticide dust animal dander coal dust mites cooking smoke and grease tobacco smoke and other particles down to 0 3 micron 1 84 000 in Airborne pollutants are carried through the return air ducts of the heating cooling system to the media air cleaner The p...

Страница 2: ...aner 1 Remove the existing furnace filter Thoroughly clean the blower compartment and ductwork where the media air cleaner is to be installed 2 Remove access door by unscrewing plastic knob Slide the filter out of the cabinet 3 Place cabinet in ductwork Holes are provided to attach cabinet to ductwork or equipment If the adjoin ing ductwork is flanged install the screws so that the screw heads are...

Страница 3: ...R RETURN AIR MEDIA AIR CLEANER RETURN AIR MEDIA AIR CLEANER RETURN AIR Fig 2 Dimensions UNIT A B C D P102 BB14A 171 16 435 26 660 1 25 21 8 55 P102 BB20 22 560 26 660 11 4 30 23 8 60 NOTE Provide a 3 ft 914 m clearance for filter removal Fig 3 Media Air Cleaner Installation Location ...

Страница 4: ...ntenance be done by the home owner If the filter is not changed on a regular basis the media air cleaner will not operate effectively Filter Replacement The filter will need to be re placed once or twice a year depending on the amount of con taminants in the air See Table 2 If the filter becomes clogged airflow through the system may be restricted This may cause service problems with the furnace o...

Страница 5: ... ENLARGED OR CHANGED BY ANY DISTRIBUTOR DEALER OR OTHER PERSON WHATSOEVER ALL WORK UNDER THE TERMS OF THIS WARRANTY SHALL BE PERFORMED DURING NORMAL WORK ING HOURS ALL REPLACEMENT PARTS WHETHER NEW OR REMANUFACTURED ASSUME AS THEIR WARRANTY PERIOD ONLY THE REMAINING TIME PERIOD OF THIS WARRANTY CARRIER WILL NOT BE REPONSIBLE FOR 1 Normal maintenance as outlined in the installation instructions inc...

Страница 6: ......

Страница 7: ......

Страница 8: ...ring obligations REPLACEMENT COMPONENTS DIVISION CARRIER CORPORATION 3 01 LITERATURE NUMBER AC 1SI PRINTED IN U S A CATALOG NO 570 617 Your Assurance of Quality ALL Totaline products are backed with a one year warranty by Carrier Corporation the world s largest manufacturer of air conditioning heating and refrigeration products ...