TOTALCOOL TOTALPOWER 500 Скачать руководство пользователя страница 15

8. FREQUENTLY ASKED QUESTIONS AND ANSWERS (FAQ)
How to check the state of charge?

1.  The battery icon display on the LCD display shows the battery level and 

charge status.

How to use the product to charge other electronic devices?

1.  Check the user manual or search for such information online to learn 

about the charging parameters of your electronic devices.

2.  Check the power of each output port. For example, the maximum rated 

output power of the AC output port is 300W. This means that if the power 

of the connected electronic device exceeds 300W for a long time, the 

inverter will turn off the output.

What is the depth of discharge (DOD)?

1.  To prolong the battery life, the product has a DOD setting to 90%, which 

means that only 90% of the battery capacity can be discharged, and retain 

10% to avoid damage to the battery due to excessive discharge.

Can it charge and discharge simultaneously?

1.  Yes, but it is not recommended to charge and discharge at the same time 

in order to protect the battery life.

Can it be charged by using 2 solar panels in parallel?

1.  Yes, just make sure the total open circuit voltage (VOC) of the solar panels 

are less than 40V, otherwise it may trigger the charging overvoltage 

protection or cause damage.

How to extend the using time of CPAP?

1.  It is recommended to turn off its humidifier, heater and set a lower 

pressure.

50Hz/60Hz frequency switching (factory setting: 60 Hz).

1.  Press the power button to turn the product on, then press the DC and AC 

button at the same time. The LCD will illuminate and display the current 

frequency (50Hz or 60Hz). Release the button and continue to the next step.

2.  Press and hold the DC button or AC button to select 50Hz and 60Hz. The 

frequency displayed on the LCD will change accordingly.

3.  After selecting the desired frequency, press the DC button and AC button 

at the same time to complete the setting. Enable after restart, step 1 can be 

repeated to check the current frequency.

USER GUIDE

15

Содержание TOTALPOWER 500

Страница 1: ...USER GUIDE...

Страница 2: ...al conditions Defect caused by non standard connectors is not compensable The company does not assume any responsibility for damage caused by not operating the product in accordance with the instructi...

Страница 3: ...s or text in or near the icons This indicates that attention should be paid to fire rupture and high temperature when operating the product Specific attention is described in the figure Represents the...

Страница 4: ...ny liquid from this product become in contact with your eyes please wash with clean water and see a doctor immediately or there may be a risk of blindness Do not let children use this product It may c...

Страница 5: ...vent electric shock Please do not put the product upside down when using or storing it It may cause leakage heat fire and other accidents When transporting the product with a car etc please fix the pr...

Страница 6: ...ether the product is damaged or missing accessories Note picture is only for reference please assume the product is the standard model USER GUIDE ITEM Portable Power Station AC adaptor including AC ch...

Страница 7: ...e status and the number under INPUT shows the real time charging power Once it is fully charged all battery segments will be lit and remain solid Note If the product malfunctions error codes would be...

Страница 8: ...the AC charger in the package 2 Please unplug the charger when charging is complete it takes about 6 7hrs to fully recharge the product if using 90W AC adapter charger Note It is normal for this produ...

Страница 9: ...ing cable and turn off the product Note Please make sure all cables are connected correctly Failure to do this can cause increased temperature status or sparking Note Please charge the product in envi...

Страница 10: ...d the LCD will display AC OFF Note Turn off these buttons to save power when not using Note The LCD background light will automatically go off after no operation for a period of time and will be on ag...

Страница 11: ...equipment requiring instantaneous high current Note The output will stop automatically after overload protection Note If the output stops repeatedly please stop using it immediately Only by eliminatin...

Страница 12: ...tc which have the function of dissolving the resin 5 Keep the product dry and in a dust free zone Do not use in temperatures above 40 C and avoid direct sunlight 6 Please fully charge the product at l...

Страница 13: ...Make sure the power button is turned on 2 Make sure the AC and DC power buttons are on viz the LED on the right of the button is green 3 Check the battery capacity if it s lower than 10 please rechar...

Страница 14: ...7 TROUBLESHOOTING CONTINUED USER GUIDE 14...

Страница 15: ...multaneously 1 Yes but it is not recommended to charge and discharge at the same time in order to protect the battery life Can it be charged by using 2 solar panels in parallel 1 Yes just make sure th...

Страница 16: ...h easily triggers AC overload Can two power stations be used in parallel 1 No DISPOSAL Place the packaging material in the appropriate recycling waste bins wherever possible If you wish to finally dis...

Отзывы: