9.2 FLOAT SWITCH SETTING 

By  lengthening or shortening the stretch of cable between the float 

a

nd  the fixed point (Float 

locking) it is possible to regulate the level at wh

i

ch the pump switches off. Ensure that the float  

witch can move freely when the pump is operating. 

Make sure the stop level does not uncover the filter.

10 PRECAUTIONS



The suction filter must always be present when during pump is operating. 



The pump must not be started more than 30 ti

m

e

s

 in one hour so as not to subject the motor to 

excessive thermal stress. 



DANGER OF FROST

: When the pump remain s inactive at temperatures of  less than 0°C, it is 

necessary to ensure that there is no water resi

d

ue which might freeze, and cause cracking of 

the pump components. 



If  the pump has been

 u

sed  with substances that tend to deposit, rinse it after

 u

se  with a 

powerful  jet of water so as to avoid the forma

t

ion  of deposits or scale which would, tend to 

reduce the pump characteristics. 

11 MAINTENANCE AND CLEANING

In  normal operation the pump does not require any type

 

of maintenance, thanks to the oil bath  

lubricated seal and to the greased-for-life bearings. 

The  electro pump  can onl

y

  be  dismantled b

y

  skilled and qualified personnel, i

n

 

possession of the technical qualifications required by the specific regulations in force.

In any case, all repair and maintenance jobs

 m

ust be carried out only after having disconnected 

the pump from the power mains, once made sure

 t

hat it cannot suddenly begin working. During 

dismantling  it  is necessary to pay great attent

i

on  to sharp parts which may cause injury. The 

cutting edge flange of the electro

 

pump is provided of aspiration fans. It is advisable, every now and 

then, to clean these fans to avoid a loss of efficiency. Best cleaning is obtained through a throw of 

water.  Sand and other  abrasive  materials cause precocious wear and tear, as

 w

ell  as loss of 

performances.

12 MODIFICATIONS AND SPARE PARTS

Any

 

modification

 

not

 

authorized

  

beforehand

 

relieves

 

the

 

manufacturer

 

of

 

all

 

 

responsibility.

All the spare parts used in repairs must be original. 

All accessories must be approved by the manufacturer so as to be able to ensure maximum safety 

of the machines and systems in which they may be fitted. 

7

Содержание TWP7110016

Страница 1: ...SUBMERSIBLE PUMP SCAN FOR VIDEO SCAN FOR VIDEO TWP775016 TWP7110016 TWP775016 5 TWP7150026 UTWP7150026 TWP7150026 5 TOTAL TOOLS WORLD...

Страница 2: ...related to suction and loss of priming The pump may be supplied with a float switch cutting out operation automatically in the event of an insufficient water level These pumps cannot be used in swimmi...

Страница 3: ...le to which a rope or cable may be connected to lower the machine into working position The pumps must never be carried lifted or operated hanging from their power cables Qualified personnel must be e...

Страница 4: ...y kind of choking of the output pipe It is advisable to use pipes with an internal diameter at least equal to that of the delivery pipe so as to avoid a fall in the performance of the pump and the pos...

Страница 5: ...tream from the pump fit a suitably sensitive magnetothermal differential switch Switch off the power upstream from the system before making the electrical connection Single phase motors are provided w...

Страница 6: ...s 1 Start the pump and observe the water flow rate 2 Stop the pump switch off the power and invert two phases on the supply line 3 Restart the pump and check the water flow rate again 4 Stop the pump...

Страница 7: ...oes not require any type of maintenance thanks to the oil bath lubricated seal and to the greased for life bearings The electro pump can only be dismantled by skilled and qualified personnel in posses...

Страница 8: ...top A The float does not interrupt the operating of the pump A Make sure float moves freely and check its efficient 4 The flow rate is insufficient A Ensure that the suction filter is not partly block...

Страница 9: ...in matter 14 TECHNICAL DATA Model No Voltage V Frequency Hz Phase Rated output kW HP No load speed min Max head m Max flow m3 H Inlet Outlet inch Cable length m 220 240 50 Single 0 75 1 0 2850 13 21 2...

Страница 10: ...10 TWP775016 TWP7110016 TWP775016 5 Exploded view...

Страница 11: ...1 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 Stator Undulated washer Bearing Rotor Bearing Screw Washer Connection part Mechanical seal O ring Oil chamber cover Screw Washer O ring Screw Oil seal Im...

Страница 12: ...TWP7150026 UTWP7150026 TWP7150026 5 Exploded view 12...

Страница 13: ...cover Bearing Rotor Bearing Stator No Part Description Qty 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 Casing O ring Screw Washer Oil chamber Mechanical seal O ring Oil chamber cover...

Страница 14: ...SUBMERSIBLE PUMP MADE IN CHINA T0821 V05 www totalbusiness com TOTAL TOOLS CO PTE LTD No 45 Songbei Road Suzhou Industrial Park China AFTER SALES QR CODE...

Отзывы: