Total TWP311001 Скачать руководство пользователя страница 9

Ensure that the mains voltage is the same as the value shown on the motor plate and that 

there is the possibility of 

MAKING A GOOD EARTH CONNECTION (Fig. E)

, in particular 

the earth terminal must be connected to the yellow/green lead of the power cable.  The 

earth lead used must be longer than the phase leads so that it does not disconnect first 

when subject to traction.

2.2

In fixed installations, International Safety Standards require the use of isolating switches 

with a fuse-carrier base.

2.3

In  normal  operation,  the  pump  does  not  require  any  specific  maintenance.  

However, it may be necessary to clean the hydraulic parts when a fall in yield is 

observed.  The electropump must not be dismantled unless by skilled personnel 

in possession of the qualifications required by the regulations in force. In any 

case, all repairs and maintenance jobs must be carried out only after having 

disconnected the pump from the power mains.

3.  STARTING UP 

4.  PRECAUTIONS

5.  MAINTENANCE AND CLEANING

Single-phase motors are provided with built-in thermal overload protection and may be 

connected directly to the mains.Three-phase motors must be protected with an automatic 

switch (e.g. overload protection) set at the values on the electropump data plate, or with 

fuses of the size indicated in chapter 4.

2.4

Switch on the power and check, on the three-phase version, that the motor is turning in 

the correct direction; this should be in a clockwise direction, looking at the motor from the 

impeller side. 

Fig. G

  If it is turning in the wrong direction, invert the connections of any 

two wires on the terminal board, after having disconnected the pump from the power 

mains.

The  electropump  should  not  be  started  more  than  20  times  in  one  hour  so  as  not  to 

subject the motor to excessive thermal shock. 

4.1

DANGER OF FROST: When the pump remains inactive for a long time at temperatures 

of less than 0°C, the pump body must be completely emptied through the drain cap Fig. 

H, to prevent possible cracking of the hydraulic components.  This operation is advisable 

even in the event of prolonged inactivity at normal temperature.

4.2

When starting after long periods of inactivity, the starting-up operations listed above must 

be repeated.

4.3

9

Содержание TWP311001

Страница 1: ...TWP37501 TWP311001 TWP315001 UTWP37501 UTWP311001 UTWP315001 TWP47501 TWP411001 TWP415001 UTWP47501 UTWP411001 UTWP415001 SELF PRIMING JET PUMP One Stop Tools Station...

Страница 2: ...he pump into operation check that the electrical cord and electrical residual current circuit breaker are not damaged h In the event that the pump is to be installed in a storm drain one must subseque...

Страница 3: ...et port 2 Outlet port 3 Terminal box 4 Motor cover 5 Motor body 6 Pump bracket 7 Ca 8 9 Pressure tank 10 Flexible hose 11 Pressure guage 12 5 Way connector 13 Pressure swith Pump body ble 1 2 3 7 5 6...

Страница 4: ...Terminal box protection IP55 Insulation class Operating range from 5 to 60 l min with head up to 45 metres Liquid quality requirements clean free from solids or abrasive substances non viscous non ag...

Страница 5: ...0 5 1 1 5 2 2 5 3 3 5 4 H ft H m P kPa 100 200 300 400 500 0 0 5 10 5 10 15 IMP gpm US gpm TWP37501 UTWP37501 TWP47501 UTWP47501 TWP311001 UTWP311001 TWP411001 UTWP411001 TWP315001 UTWP315001 TWP41500...

Страница 6: ...le Single Single Single Rated output kW Hp 0 75 1 0 0 75 1 0 1 1 1 5 1 1 1 5 No load speed min 2850 3450 2850 3450 Capacitor uf 20 35 20 60 Max head m 45 45 60 60 Max suction m 9 9 9 9 9 9 Max flow L...

Страница 7: ...OPERATION INSTRUCTION 7...

Страница 8: ...in on the apertures thus preventing deformations or breakages Fig C 1 4 It is always good practice to place the pump as close as possible to the liquid to be pumped The pump must be installed only in...

Страница 9: ...provided with built in thermal overload protection and may be connected directly to the mains Three phase motors must be protected with an automatic switch e g overload protection set at the values o...

Страница 10: ...slackening the respective screws and slip off the cable which is now disconnected Section of cable from the pressure switch to the terminal board unscrew the nut from the cover of the pressure switch...

Страница 11: ...mp does not prime A The intake pipe or the foot valve is taking in air B The downward slope of the intake pipe favours the formation of air pockets A Eliminate the phenomenon and prime again B Correct...

Страница 12: ...ption 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 Rotor shaft Bearing Terminal block Gasting with wound stator Bolt Screw Fairlead Screw Cable presser Terminal cover Capacitor Driving cap Tie rod...

Страница 13: ...13 Exploding view TWP37501 TWP311001 TWP315001 TWP47501 TWP411001 TWP415001 UTWP37501 UTWP311001 UTWP315001 UTWP407501 UTWP411001 UTWP415001...

Страница 14: ...SELF PRIMING JET PUMP T1116 V07 MADE IN CHINA www totaltools cn TOTAL TOOLS CO LIMITED One Stop Tools Station...

Отзывы: